Looking for a Replacement Manual for Pro-face GP-3310T? Download the manual for free from 88.208.23.73:8080. Get all the information you need to operate this high-quality product efficiently. The user manual is just a click away!
1
Easy! Smooth! GP-3310T->GP4000 Series Replacement Guidebook
First Edition Jul. 2012
Copyright © 2012.7 Digital Electronics Corporation. All Rights Reserved.
Page 1: ...1 Easy Smooth GP 3310T GP4000 Series Replacement Guidebook First Edition Jul 2012 Copyright 2012 7 Digital Electronics Corporation All Rights Reserved...
Page 2: ...No Recommended Substitution GP 3310T AGP3310 T1 D24 GP 4401WW Safety Information HAZARD OF OPERATOR INJURY OR UNINTENDED EQUIPMENT DAMAGE Before operating any of these products be sure to read all re...
Page 3: ...5 3 GP 4300 series 5 7 4 GP 4400 series 7 5 7 0 W 5 GP 4500 series 10 4 6 GP 4600 series 12 1 B 01 RS 232C 422 485 03 RS 485 isolation C T TFT color LCD W TFT color LCD Wide Type D A Analog Resistive...
Page 4: ...W 6 CHAPTER 2 COMPATIBILITY OF HARDWARE 8 2 1 LOCATIONS OF CONNECTOR 8 2 2 DISPLAY RESOLUTION 10 2 3 PANEL CUTOUT DIMENSIONS 10 2 4 TRANSFER CABLE 11 2 5 INTERFACE 11 2 5 1 SERIAL INTERFACE 11 2 5 2 C...
Page 5: ...5 TRANSFER SCREEN DATA TO GP 4401WW 26 3 6 DIFFERENCES OF SOFTWARE 31 CHAPTER 4 COMMUNICATION WITH DEVICE PLC 32 4 1 DRIVERS 32 4 1 1 CONNECTABLE DEVICES 32 4 1 2 CONNECTING TO MULTIPLE DEVICE PLCS 3...
Page 6: ...VGA 640x480 pixels NEW WVGA 800x480 pixels See 2 2 Panel Cutout Dimensions mm 156 W 123 5 H 204 5 W 159 5 H See 2 3 External Dimensions mm 167 5 W x135 H x59 5 D 218 W x173 H x60 D Touch Panel Type R...
Page 7: ...hapter 4 COM2 D Sub 9 pin socket RS 422 485 D Sub 9 pin plug RS 422 485 See 2 5 1 and Chapter 4 Ethernet I F 10BASE T 100BASE TX CF Card I F See 2 5 2 SD Card I F NEW USB I F Type A 2 ports 1 port See...
Page 8: ...8 Chapter 2 Compatibility of Hardware 2 1 Locations of connector Connector locations on GP 3310T and GP 4401WW are as follows GP 3310T GP 4401WW...
Page 9: ...1 Power Connector 2 Serial Interface COM1 3 Serial Interface COM2 4 Ethernet Interface 5 USB Interface Type A 6 USB Interface Type mini B 7 SD Card Interface F 8 CF Card Interface 9 Expansion Unit In...
Page 10: ...an adjust both size and location of the part and the text relative to the display resolution automatically But please note that their width gets larger due to change of horizontal resolution of the sc...
Page 11: ...WW the pin assignment and the shape of plug socket connector are different To know the details about them see 4 2 Shapes of COM ports and 4 3 Signals of COM ports Because of it the existing PLC connec...
Page 12: ...http www pro face com otasuke files manual gpproex new device index h tm If it s not possible to use USB RS 422 485 Conversion Adapter PFXZCBCBCVUSR41 for your connection please contact our sales off...
Page 13: ...ed to use an USB hub supporting self power supply and be sure to check the operation Also several USB devices of the same category in the following table cannot be simultaneously used Even if multiple...
Page 14: ...ed with an expansion unit interface The expansion units each kind of unit like CC LINK Unit for GP 3310T cannot be used 2 6 4 Isolation Unit RS 485 isolation unit for GP 3310T CA3 ISO485 01 cannot be...
Page 15: ...onsumption The power consumption of GP 3310T is different from that of GP 4401WW GP 3310T 26W or less GP 4401WW 12W or less For the detailed electric specifications see the hardware manual 2 9 Materia...
Page 16: ...to GP 4401WW replace GP 3310T with GP 4401T instead of GP 4401WW To check SRAM size follow the steps below 1 Double click and open the project file prx on GP Pro EX 2 Change the Display Unit type to...
Page 17: ...s cable Start connection and check the communication Remove GP 3310T Connect the power cord Check the performance and start operation Installation Screen Communication Install GP 4401WW Check the comp...
Page 18: ...vailable A USB transfer cable model CA3 USBCB 01 A USB data transfer cable model ZC9USCBMB1 A commercial USB cable USB Type A mini B Possible to send receive a screen with a SD card a USB storage devi...
Page 19: ...model CA3 USBCB 01 A CF card USB storage device Ethernet But this section explains as an example how to receive screen data from GP 3310T using a USB transfer cable model CA3 USBCB 01 If you have back...
Page 20: ...depending on the security level of Windows XP Click Continue Anyway to start installing the driver When installation is completed click Finish If the following symptoms appear on Microsoft Windows 7 g...
Page 21: ...P Pro EX 3 Make sure that the Device in the Transfer Settings Information is set to USB If not click the Transfer Setting button to open the Transfer Setting dialog box Select USB in the Communication...
Page 22: ...ransfer Tool and click the Receive Project button 5 Click Receive Project and the following dialog box will appear Specify a place to save the received data in and a project file name and then click S...
Page 23: ...or not to overwrite the file is displayed 6 The following dialog box appears during transfer and you can check the communication status The display unit enters the Transferring mode and communication...
Page 24: ...ompleted GP 4401WW that is a replacement model is not equipped with a CF card slot If the display unit type is changed to GP 4401WW the CF card setting will be replaced with the SD card setting automa...
Page 25: ...the received project file prx of GP 3310T on GP Pro EX and change the display unit type to GP 4401WW 1 Open the received project file prx on GP Pro EX 2 Click System Settings Display Change Display i...
Page 26: ...rea After changing the Display Unit type confirm size and location of the part text and edit the screens if necessary 3 Click Project Save As and save the changed project data 3 5 Transfer screen data...
Page 27: ...nstalled on you PC a dialog box will appear Please follow the instructions NOTE The Hardware Installation dialog box as shown below may appear during installing the USB driver depending on the securit...
Page 28: ...download freesoft gpproex_transfer ht m An error occurs when GP Pro EX or Transfer Tool is installed An error occurs when data is transferred via a USB transfer cable model CA3 USBCB 01 2 Turn on the...
Page 29: ...a different project file click the Select Project button and select a project file 4 Make sure that the Device in the Transfer Settings Information is set to USB If not click the Transfer Setting butt...
Page 30: ...following dialog box appears during transfer and you can check the communication status The display unit enters the Transferring mode and communication with the device such as a PLC is terminated 7 W...
Page 31: ...k on top right of the screen or Project Exit to close GP Pro EX 3 6 Differences of software Some functions supported by GP 3310T are not supported by GP 4401WW For details of the supported parts and f...
Page 32: ...ent depending on the state of the connection with your Device PLC Number of Device PLC Drivers 1 GP 3310T Connection Replacement Model 1 Any connection GP 4401WW 2 COM1 RS 422 485 COM2 RS 422 485 Ethe...
Page 33: ...33 4 2 Shapes of COM ports GP 3310T GP 4401WW COM1 D Sub 9 pin plug RS 232C 422 485 D Sub 9 pin plug RS 232C COM2 D Sub 9 pin socket RS 422 485 D Sub 9 pin plug RS 422 485...
Page 34: ...3 1 Signals of COM1 For GP 3310T RS 232C plug 1 RI and VICC of Pin 9 are switched on the software VCC Output is not protected from overcurrent Please follow the current rating to avoid false operation...
Page 35: ...35 For GP 4401WW RS 232C plug 1 RI and VICC of Pin 9 are switched on the software VCC Output is not protected from overcurrent Please follow the current rating to avoid false operation or breakdown...
Page 36: ...4 3 2 Signals of COM2 For GP 3310T RS 422 485 socket 1 VCC Output is not protected from overcurrent Please follow the current rating to avoid false operation or breakdown For GP 4401WW RS 422 485 plu...
Page 37: ...d for GP 4401WW But please note that there are precautions and restrictions as described below When a RS 422 485 device is connected via the COM1 port it will be connected via the COM2 port of GP 4401...
Page 38: ...4401WW with a COM Port Conversion Adapter CA3 ADPCOM 01 added in the following cases In all other cases the operation is not guaranteed and it s recommended to prepare a new connection cable To check...
Page 39: ...1 After conversion of the project file data at GP Pro EX Error Check if the message The project contains features that require a SD card However the selected display does not support SD cards so these...
Page 40: ...ormation Destination Folder ii Uncheck Enable SD Card and check Enable USB Storage iii Click the Browse button and specify a destination folder iv Click OK to confirm the setting v Click Project Save...
Page 41: ...X Reference Manual 2 Check and change the destination folder setting following the steps below i Click Project Information Destination Folder ii The current setting is displayed iii After changing it...