WARNING

• When connecting a power cable to the GP unit, be sure the cable has been

unplugged from the power outlet, so that you would not get an electric shock.

• High voltage runs in the GP unit, so if you take unit apart, there is a danger of

getting an electric shock.  Do not take the unit apart.

• Do not use power beyond the specified voltage range.  If you do, it may cause a

fire or an electric shock.

• Do not reconstruct the GP unit.  It may cause a fire or an electric shock.
• Do not use the GP in an environment with flammable gas in the surrounding

atmosphere.  It may cause explosion.

• GP use a lithium battery for backing up its internal clock data.  If the battery is

incorrectly replaced, the battery may explode.  To avoid the danger, do not
replace the battery yourself.  When the battery needs a replacement, please
consult with your local GP distributor.

• Do not use touch panel switches in life-related or important disaster prevention

situations.  For safety related switches, such as an emergency switch. use a
separate mechanical switch.

• Please design your system so that the machine will not malfunction by a commu-

nication fault between the GP and its host controller.  If not, there could be a
danger of injuring a person or damaging materials.

To Prevent From Damage:

• Do not hit the touch panel with a hard or heavy object, or press the touch panel

with too much force, for it may cause irreparable damage.

• Do not use GP in an environment where the surrounding temperature exceeds

the specification range, for it may damage the unit.

• Please ensure that liquids or metal do not enter the GP unit, for it may cause

malfunction or a short.

• Please avoid using the unit in areas where sudden, large changes in tempera-

ture may occur.  These changes can cause condensation to form inside the
unit, possibly causing an accident.

• To prevent from heat building up inside the GP, please do not install GP where its

ventilation holes may be blocked, or where heat cannot escape.  Also, please
avoid using or storing the GP in an extremely hot place.

• Do not operate the GP in areas with temperatures and humidity in express of

those levels specified to prevent the GP’s touch panel from becoming warped or
bent.

• Please avoid using or storing the GP under direct sunlight or in a dusty environ-

ment.

• This unit is a delicate equipment, so please avoid using or storing the GP unit in

an environment where it can receive strong impact or vibration.

• Please avoid using or storing GP where vaporized chemicals or chemicals can

stick to it.

• Do not use paint thinner or organic solvents to clean the GP unit or display.
• Because unforeseen circumstances may befall your GP unit, be sure to back

up your screen data.

• After turning this unit OFF, be sure to wait a few seconds before turning ON

again. If the unit is started within a few seconds, it may not start up correctly.

Summary of Contents for GP-477R Series

Page 1: ... or press the touch panel with too much force for it may cause irreparable damage Do not use GP in an environment where the surrounding temperature exceeds the specification range for it may damage the unit Please ensure that liquids or metal do not enter the GP unit for it may cause malfunction or a short Please avoid using the unit in areas where sudden large changes in tempera ture may occur Th...

Page 2: ...g damaged or missing please contact your local GP distributor immediately Package Contents Manual GP477R 577R Series User s Manual Extra Cost Options Cables Adapters Screen editor software are optionally available For more information see Digital s cata logues GP unit GP477R EG11 Handling guide 1 sheet this sheet Installation fasteners 4 pcs Handling Guide Digital GP477R 577R Series User s Manual ...

Page 3: ...d terminals for AC power cable E Auxiliary Input Output AUX Operates the Touch Switch System Alarm Buzzer Run outputs and Remote Reset inputs F Serial Interface RS 232C RS 422 Serial interface Connect to the Host G Printer Interface Connect the printer here H Tool Connector Connect the Downloading Cable or a Bar Code Reader here D F E G H A B C unit mm Front View 274 216 Top View 258 56 5 200 7 5 ...

Page 4: ...re to connect this unit s SG GND SignalGround terminal to the other unit sSignalGroundterminal Pin Signal Name Condition Pin Signal Name Condition 1 FG Frame ground 14 VCC 5V 5 output 0 25A 2 SD Send data RS 232C 15 SDB Send data B RS 422 3 RD Receive data RS 232C 16 RDB Receive data B RS 422 4 RS Request send RS 232C 17 NC No connection 5 CS Clear send RS 232C 18 CSB Clear send B RS 422 6 NC No c...

Page 5: ...B1 4 PDB2 5 PDB3 6 PDB4 7 PDB5 8 PDB6 9 PDB7 10 1 INIT 11 BUSY 12 NC 13 NC 14 GND When making a cable please be aware of the following For RS 422 Connection The following pairs of pin s must be connected to each other 18 CSB 19 ERB 21 CSA 22 ERA When connecting the RS 422 cable and the 9 TRMX and 10 RDA points a termination resistance of 100Ω is added between RDA and RDB When the GP is set as a Me...

Page 6: ...pin Cover XM2S 1511 made by OMRON Corp Jack Screw XM2Z 0071 made by OMRON Corp Use rough metric type M2 6 x 0 45p threads used to hold the cable s set fastening screws in place 5 AUX Interface Input Output Pin Connection Pin Signal Name Contents 1 TSW0 2 TSW1 3 TSW2 4 TSW3 5 TSW4 6 TSW5 7 TSW6 8 TSW7 Touch Switch Output 8 bit 9 RUN Output On in RUN mode Off in standby mode or when the power is off...

Page 7: ...orque necessary for waterproofing is 0 5 0 6N m Panel GP unit 1 0 1 0 Before installing the GP into a cabinet or panel check that the Installa tion gasket is securely attached to the unit Confirm the Installation Gasket s Seating It is strongly recommended that you use the gasket Place the GP on a level surface with the display panel facing downward Check that the GP s installation gasket is seate...

Page 8: ...connected to the GP chassis 1 Ring Terminal to use V2 MS3 made by JST To avoid a short among the ring terminals when the screws get loosen please use ring terminals with a sleeve Rear side N L FG L N FG Ring Terminals 1 7 Wiring To avoid electric shock be sure the Power Cable is unplugged from the power outlet when connecting the cable to the GP unit GP477R EG11 can only take AC100V input If you s...

Page 9: ...t If the supply voltage exceeds the GP unit range connect a voltage trans former For between the line and ground select a power supply that is low in noise If there is an excess amount of noise connect a noise reducing trans former When supplying power to the GP unit please separate the input output and operation unit lines To increase the noise quality simply twist the power cable before connect ...

Page 10: ...ithin ground resistance of 100 W 9 Precaution for Grounding 10 Precautions for Input Output Signal Lines Input and Output signal lines must be separated from the power control cables for operational circuits If this is not possible use a shielded cable and the shield should be grounded ...