CAUTIONS

Installation

Be sure to securely connect all cable connectors to the GP.  A loose connection may cause incorrect
input or output.

Wiring

Ground the GP's FG line separately from other units’ FG lines. Putting these FG lines too close
may cause an electric shock or unit malfunction. Be sure to use a grounding resistance of 100

 or

less and a 2mm

2

 or thicker wire, or your country’s applicable standard.

Correctly wire the GP, be sure that the rated voltage and terminal layout are within the designated
range. If the voltage supplied differs from the rated voltage, or incorrect wiring or grounding is
performed, it may cause a fire or unit malfunction.

Use only the designated torque to tighten the GP's terminal block screws. If these screws are not
tightened firmly, it may cause a short-circuit, fire, or GP malfunction.

Be careful that metal filings and wiring debris do not fall inside the GP, since they can cause a fire,
GP malfunction, or incorrect operation.

Maintenance

The liquid crystal panel contains a powerful irritant and if for any reason the panel is damaged and
this liquid contacts any part of your body, be sure to wash that area with running water for 15
minutes. If any of this liquid enters your eye, flush your eye for 15 minutes with running water and
contact a physician.

Prior to inserting or removing a CF Card, be sure to turn the GP’s CF Card ACCESS switch OFF
and to confirm that the ACCESS lamp is not lit.  If you do not, CF Card internal data may be
damaged or lost.

While a CF Card is being accessed, NEVER turn OFF or reset the GP, or insert or remove the CF
Card. Prior to performing these operations, create and use a special GP application screen that will
prevent access to the CF Card.

Unit Disposal

When this unit is disposed of, it should be done so according to your country's regulations for
similar types of industrial waste.

General Safety Precautions

Do not strike the touch panel with a hard or pointed object, or press on the touch panel with too
much force, since it may damage the touch panel or the display.

Do not install the GP where the ambient temperature can exceed the allowed range. Doing so may
cause the GP to  malfunction or shorten its operation life.

Do not restrict or limit the GP’s naturally occurring rear-face ventilation, or storing or using the GP
in an environment that is too hot.

Do not use this unit in areas where large, sudden temperature changes can occur. These changes
can cause condensation to form inside the unit, possibly causing the unit to malfunction.

Do not allow water, liquids, metal or charged particles to enter inside the GP’s case, since they can
cause either a GP malfunction or an electrical shock. The allowable pollution degree is 2.

Do not use or store the GP in direct sunlight, or in excessively dusty or dirty environments.

Do not store or use the unit where strong jolting or excessive vibration can occur.

Do not store or use the GP where chemicals (such as organic solvents, etc.) and acids can evapo-
rate, or where chemicals and acids are present in the air.
Corrosive chemicals:

Acids, alkalines, liquids containing salt

Flammable chemicals:

Organic Solvents

Do not use paint thinner or organic solvents to clean the GP.

Do not store or operate the LCD display in areas receiving direct sunlight, since the sun's UV rays
may cause the LCD display’s quality to deteriorate.

Storing this unit in areas at a temperature lower than is recommended in this manual’s specifica-
tions may cause the LCD display’s liquid to congeal, which may damage the panel. Conversely, if
the storage area’s temperature becomes higher than the allowed level, the LCD’s liquid will be-
come isotropic, causing irreversible damage to the LCD. Therefore, be sure to store the panel only
in areas where temperatures are within those specified in this manual.

After turning the GP OFF, be sure to wait a few seconds before turning it ON again. If the GP
started too soon, it may not start up correctly.

Due to the possibility of unexpected accidents, be sure to back up the GP’s screen data regularly.

Summary of Contents for GP2500-TC41-24V

Page 1: ...chanical interlocks After the GP s backlight burns out unlike the GP s Standby Mode the touch panel is still active If the operator fails to notice that the backlight is burned out and touches the pan...

Page 2: ...h a hard or pointed object or press on the touch panel with too much force since it may damage the touch panel or the display Do not install the GP where the ambient temperature can exceed the allowed...

Page 3: ...ecome higher than that allowed by UL stan dard requirements UL1604 Conditions of Acceptability and Handling Cautions 1 Power input and output I O wiring must all be in accordance with Class I Division...

Page 4: ...s unit has been carefully packed with special attention to quality However should you find anything damaged or missing please contact your local GP distribu tor immediately Package Contents GP Unit 1...

Page 5: ...I F 25 pin L Serial Interface SUB SIO 9 pin M Printer Interface Half Pitch 20 pin N Ethernet Interface O Screw Lock Terminal Block P Tool Connector Connects a Data Transfer Cable or bar code reader D...

Page 6: ...te 1 This Dip switch setting controls the startup from a CF Card Startup from CF Card is enabled Startup from CF Card is disabled CF Card with startup data required 2 Reserved 3 Reserved 4 This settin...

Page 7: ...Interfaces Recommended Connector Dsub 25 pin plug XM2A 2501 made by OMRON Corp Recommended Cover Dsub 25 pin Cover XM2S 2511 made by OMRON Corp Jack Screw XM2Z 0071 made by OMRON Corp Recommended Cabl...

Page 8: ...V 5 0 25A Recommended Connector Dsub 9 pin plug XM2D 0901 made by OMRON Corp Recommended Cover Dsub 9 pin cover XM2S 0913 made by OMRON Corp Jack Screw XM2Z 0073 made by OMRON Corp Since Pin 9 RI VCC...

Page 9: ...aight sections of the groove Inserting it into a corner may lead to its eventually tearing A gasket which has been used for a long period of time may have scratches or dirt on it and could have lost m...

Page 10: ...nstallation fastener Create a Panel Cut and insert the GP into the panel from the front Attach the Installation Fasteners from Inside the Panel The following figures show the four 4 fastener insertion...

Page 11: ...al Block Rear of GP Ring Terminals 1 1 Suggested Ring Terminal V2 MS3 made by JST Connecting the GP Power Cord When connecting the power cord be sure to follow the procedures given below 1 Confirm tha...

Page 12: ...ion to the following instructions when connecting the power cord terminals to the GP unit If the power supply voltage exceeds the GP s specified range connect a voltage transformer Between the line an...

Reviews: