25
Installation
En
g
lish
Installation procedure
Step
Procedure Details
1
Cut an opening in the panel to match the standard mount or flat
mount panel cut dimensions, and then weld four M4 x 10L stud
bolts perpendicular to the rear surface of the panel in order to fix
the GP unit in place.
Note :
• Before you start this work, carefully read "3. Panel Cut Dimensions" (see
page 20).
• Prepare four stud bolts and four nuts within your quality assurance range.
• The stud bolt height is 10 mm (0.39 in).
• We recommend that you use M4 nuts (ISO4032, JIS B 1181).
10
0.39
mm
in.
Installation diagram (profile)
8.1
3.2
0.13
0.32
7
0.28
mm
in.