When installing the PS-A in a slanted panel, the panel face should not incline more than 30°.
•
When installing the PS-A in a slanted panel, and the panel face inclines more than 30°, the surrounding air
temperature must not exceed 40°C. You may need to use forced air cooling (fan, A/C) to ensure the
surrounding air temperature is 40°C or below.
•
The PS-A Series unit does not support longitudinal mounting.
Installing the PS-A
(1)
Insert the PS-A into the panel cut, as shown.
(2)
Insert each fastener’s hook into the slot and tighten
it with a screwdriver. Insert the installation
fasteners securely into the insertion slot recess.
There are eight insertion slots.
30° or less
Insertion
Slots