A-2
PS-400G Series User Manual
1 Specifications
1.1 Electrical
1.2 Environmental
*1 If the PS-G’s operating temperature exceeds 40ºC for an extended period of time, the display
quality, such as the contrast, etc., may degrade. If, however, the operating temperature is
reduced to 40
0
C or less, the display quality will return to normal.
Ambient Operating Temperature
(Panel interior and Panel face)
0
°
C to 50
°
C*1
Storage Temperature
-20
°
C to +60
°
C
Ambient Humidity
10%RH to 90%RH
(non-condensing, dry bulb temperature : 39°C or less)
Dust
0.1mg/m
3
or less
(Non-conductive particles)
Atmosphere
Free of corrosive gases
Air-pressure Resistance
(Operating altitude)
800 hPa to 1114 hPa
(2000 meters or lower)
Vibration Resistance
IEC61131-2 (JIS B 3501) compliant
When vibration is NOT continuous
10Hz to 57Hz 0.075 mm, 57Hz to 150Hz 9.8m/s
2
When vibration is continuous
10Hz to 57Hz 0.035 mm, 57Hz to 150Hz 4.9m/s
2
X,Y,Z directions for 10 times (80min.)
Noise Immunity
(via noise simulator)
Noise Voltage: 1500 Vp-p
Pulse Duration: 1x10
-6
sec.
Rise Time: 1ns
Electrostatic Discharge
Immunity
Contact Discharge
6kV (IEC 61000-4-2 Level 3)
Input Voltage
DC24V
Rated Voltage
DC19.2V to DC28.8V
Allowable Voltage Drop
10 ms or less
Power Consumption
28W or less
In-rush Current
30A or less
Voltage Endurance
Voltage Endurance
AC1000V, 20mA for up to 1 minute
(between charging and FG terminals)
Insulation Resistance
Insulation Resistance
10M
.
or more at DC500V
(between charging and FG terminals)