Dimensions/Assembly
50
Panel Cut Dimensions
For cabinet installation, you need to cut the correct sized opening in the installation
panel.
The dimensions of the opening for installing the Industrial Personal Computer are
shown below:
Standard Models
1
Installation panel
A
301.5 +1/0 mm (11.87 +0.04/0 in.)
B
227.5 +1/0 mm (8.96 +0.04/0 in.)
C
1.6...9 mm (0.06...0.35 in.)
Rear Mount Models
137.5
(+0.5/0)
132.5
(+0.5/0)
5.41
(+0.02/0)
1.5
0.06
Center of
the display
Center of
the cut-out
5.22
(+0.02/0)
123
(±0.1)
9.7
12.3
123
(±0.1)
4.84
(±0.004)
0.38
1.3
0.05
0.48
102.7
(+0.5/0)
4.04
(+0.02/0)
103.3
(+0.5/0)
4.07
(+0.02/0)
4.84
(±0.004)
mm
in.
146
(±0.1)
5.75
(±0.004)
141.5
ø5 (2x)
ø6 (4x)
5.57
146
(±0.1)
5.75
(±0.004)