Wiring and Connecting the Terminal Block
The table below describes how to connect the power cord to the DC Industrial
Personal Computer:
Step
Action
1
Remove all power from the Industrial Personal Computer and confirm that the
DC power supply has been disconnected from its power source.
2
Remove the terminal block from the power connector and connect the power
cord to the terminal block as shown below:
Use 75 °C (167 °F) wire.
Use wire with cross-section 0.75 to 2.0 mm
2
(AWG 18 to AWG 14).
3
Place the terminal block in the power connector and tighten the screws.
NOTE:
The recommended torque to tighten these screws is 0.5 Nm (4.5 lb-in).