background image

English

Customer Hotline 1-800-445-1805

3

SAFETY AND OPERATION RULES

WARNING indicates a 

potentially hazardous situation

which, if not avoided, could

result in death or serious injury.  

CAUTION indicates a potentially

hazardous situation which, if not

avoided, may result in minor or 

moderate personal injury, or 

property damage. 

WARNING - Failure to follow these instructions
and warnings may result in death, personal
injury, or property damage.

1. Read carefully and understand operator manual 

prior to operation of this product.  Follow all 
warnings and instructions.

2. Know your equipment.  Consider the applications, 

limitations, and the potential hazards specific to 
your unit.

3. Equipment must be placed on a firm, supporting 

surface.

4. Load must be kept within rating stated on 

generator nameplate.  Overloading will damage 
the unit or shorten its life.

5. Engine must not be run at excessive speeds. 

Operating an engine at excessive speeds increases 
the hazard of personal injury.

Do not tamper with parts which may increase 
or decrease the governed speed.

6. To prevent accidental starting, always remove the 

spark plug or cable from the spark plug before 
maintaining the generator or engine.

7. Units with broken or missing parts, or without 

protective housing or covers, should never be 
operated.  Contact your service center for 
replacement parts.

8. Units should not be operated or stored in wet or 

damp conditions or on highly conductive 
locations such as metal decking and steel work.

9.  Keep the generator clean and free of oil, mud and 

other foreign matter.

10.Extension cords, power cords, and all electrical 

equipment must be in good condition. Never 
operate electrical equipment with damaged or 
defective cords.

11. Store the generator in a well ventilated area with 

the fuel tank empty. Fuel should not be stored near 
the generator.

12.Your generator should never be operated under 

these conditions:
a. Uncontrolled change in engine speed. 
b. Electrical output loss.
c. Overheating in connected equipment.
d. Sparking.
e. Damaged receptacles.
f. Engine misfire.
g. Excessive vibration.
h. Flame or smoke.
i. Enclosed compartment.
j. Rain or inclement weather.  Do not let the unit 

get wet when operating.

13.Check the fuel system periodically for leaks or 

signs of deterioration such as chafed or spongy 
hose, loose or missing clamps, or damaged tank or 
cap. All defects should be corrected before 
operation.

14.The generator should be operated, serviced, and 

refueled only under the following conditions:

a. Start and run the generator outdoors.  Do 

not run the generator in an enclosed area, 
even if doors or windows are open; avoid 
areas where vapors may be trapped, such as 
pits, garages, cellars, excavations and boat 
bilges.  DANGER - CARBON MONOXIDE 
HAZARD: The engine exhaust contains 
carbon monoxide, a poisonous, odorless, 
invisible gas which, if breathed, may cause 
death or serious personal injury.  If you start 
to feel sick, dizzy or weak while using the 
generator, shut it off and get to fresh air 
right away; you may have carbon monoxide 
poisoning.

b. Good ventilation for cooling.  Air flow and 

temperatures are important for air cooled 
units.  Temperatures should not exceed 104º F
ambient (40º C).

c. Refuel the generator in a well lighted area. 

Avoid fuel spills and never refuel while the 
generator is running.  Allow engine to cool for 
two minutes prior to refueling.

DANGER indicates a potentially

hazardous situation which, if not
avoided, WILL result in death or

serious injury.  

Summary of Contents for Proforce PM0103000

Page 1: ...nual Manuel de l op rateur Manual del operador Record the serial numbers as indicated on your Generator s nameplate Serial No ____________________________ Enregistrer le num ro de s rie figurant sur l...

Page 2: ...riodique 21 Entretien 21 La bougie d allumage 21 Le type d huile 21 Remplacement d huile 21 Nettoyage du filtre air 21 Nettoyage du filtre du robinet essence 21 Nettoyage de la cr pine du r servoir c...

Page 3: ...n good condition Never operate electrical equipment with damaged or defective cords 11 Store the generator in a well ventilated area with the fuel tank empty Fuel should not be stored near the generat...

Page 4: ...D WITH A SPARK ARRESTING MUFFLER If the product will be used around flammable materials such as agricultural crops forests brush grass or other similar items then an approved spark arrester should be...

Page 5: ...bustible Engines 3 Agricultural Wiring handbook of Farm Standby Electric Power 5 English Customer Hotline 1 800 445 1805 OPERATING VOLTAGE CAUTION Operating voltage and frequency requirement of all el...

Page 6: ...ening of the oil fill LOW OIL SENSOR The unit is equipped with a low oil sensor If the oil level becomes lower than required the sensor will activate a warning device or stop the engine If generator s...

Page 7: ...e the cause of the problem before attempting to use the generator again If overloading causes the circuit breaker to trip reduce the load NOTE Continuous tripping of the circuit breaker may cause dama...

Page 8: ...0 bolt item 160 Thread a M8 nut item 162 to the bolt to secure the assembly Caution Do not over tighten so that the foot material collapses 2 Repeat above instructions for the remaining foot HANDLE IN...

Page 9: ...ped 5 Close the fuel shut off valve if the engine is to be put in storage or transported 6 If a cover is used do not install until unit has cooled STARTING THE UNIT Gasoline is very dangerous Serious...

Page 10: ...and gently squeeze out any excess oil 4 Replace the filter element and air filter cover 5 Be sure the filter cover seals properly all around FUEL VALVE FILTER CLEANING 1 Remove the cup at the bottom...

Page 11: ...en 5 Check all generator parts for integrity 6 Clean the Carburetor INFREQUENT SERVICE If the unit is used infrequently difficult starting may result to eliminate hard starting run the generator at le...

Page 12: ...P 3600 rpm Starting System Recoil electronic ignition Driving System Direct coupling tapered crank Oil Capacity 20 oz Spark Plug Champion RN14YC or equivalent Governor Mechanical adjustable Cooling Sy...

Page 13: ...ne Damages caused by abuse or accident and the effects of corrosion erosion and normal wear and tear Warranty is voided if the customer fails to install maintain and operate the product in accordance...

Page 14: ...eil lectrique doivent tre en bon tat Ne jamais faire fonctionner un appareil lectrique dont le cordon d alimentation est ab m ou d fectueux 11 Rangez le nettoyeur haute pression dans un endroit bien v...

Page 15: ...21 Avant de transporter la g n ratrice dans un v hicule le vider de tout carburant afin d emp cher les fuites 22 Pour transporter l appareil d un site l autre utilisez les bonnes techniques de levage...

Page 16: ...isation des moteurs fixes combustible 3 Manuel de c blage du r seau d alimentation de secours des appareils agricoles 16 Fran ais V RIFIER LA TENSION ATTENTION V rifier la tension et la fr quence requ...

Page 17: ...au limite le d tecteur activera un appareil qui avertit ou arr te le moteur Si le groupe lectrog ne s arr te mais qu il y a suffisamment d huile v rifier s il se trouve sur un plan inclin entra nant l...

Page 18: ...u probl me avant d essayer de le r utiliser Si le disjoncteur saute en raison d une surcharge r duire la charge REMARQUE Le groupe lectrog ne ou les appareils branch s dessus peuvent se trouver ab m s...

Page 19: ...boulon un crou M8 article 162 Attention ne pas trop serrer pour ne pas craser le mat riau du pied 2 Proc der de la m me fa on pour l autre pied POSE DE LA POIGNEE 1 Mettre la poign e article 156 sur l...

Page 20: ...phonique 1 800 445 1805 L essence est un produit tr s dangereux Un incendie r sultant du contact de l essence avec des surfaces chaudes peut causer de graves blessures ou entra ner la mort 1 Ne pas me...

Page 21: ...t et le couvercle du filtre air en place 5 S assurer de la parfaite tanch it du pourtour du couvercle du filtre NETTOYAGE DU FILTRE DU ROBINET ESSENCE 1 Retirer la coupelle du bas du robinet essence a...

Page 22: ...t essence soit ouvert 5 V rifier les pi ces du groupe lectrog ne afin de vous assurer de leur int grit 6 Nettoyer le carburateur USAGE PEU FR QUENT Si la g n ratrice est rarement utilis e il est possi...

Page 23: ...st me de propulsion Accouplement direct bilegrequin effil Capacit d huile 20 oz Bougie Champion RN14YC ou l quivalent R gulation M canique ajustable Syst me de refroidissement Refroidissement air forc...

Page 24: ...osion de l rosion ainsi que de l usure normale La garantie est annul e si le client n arrive pas installer garder et faire fonctionner le produit conform ment aux directives et aux recommandations de...

Page 25: ...generador 12 Su generador no deber operarse jam s si ocurre do lo siguiente a Cambio fuera de control en la velocidad del motor b P rdida de carga el ctrica c Sobrecalentamiento del equipo conectado d...

Page 26: ...se lesiones personales 23 Para evitar quemaduras no toque el silenciador del motor u otras superficies del generador que se hayan calentado durante la operaci n PUEDE SER QUE SU PRODUCTO NO ESTE EQUIP...

Page 27: ...ci n auxiliar para granjas 27 Espa ol PRECAUCION El requerimiento de voltaje y frecuencia operativa de todos los equipos electr nicos debe comprobarse antes de enchufarlos a este generador Pueden ocur...

Page 28: ...r que el requerido el sensor activar un artefacto de la advertencia o parar el motor Si se apaga el generador y el nivel de aceite se encuentra dentro de las especificaciones verifique que el generado...

Page 29: ...e de determinar la causa del problema antes de usar el generador nuevamente Si la sobrecarga causa que salte el cortacircuitos reduzca la carga NOTA Si salta continuamente el cortacircuitos se podr a...

Page 30: ...art culo 162 al perno para asegurar el ensamble Precauci n No apriete demasiado para que el material de la pie no colapse 2 Repita el procedimiento anterior para la otra pie INSTALACI N DE LA MANIJA 1...

Page 31: ...l ctrico 4 No abandone el generador hasta que se haya detenido por completo L nea Directa 1 800 445 1805 ARRANQUE DEL UNIDAD La gasolina es muy peligrosa Si la gasolina hace contacto con superficies c...

Page 32: ...ltro y la cubierta del filtro de aire 5 Aseg rese de que la cubierta del filtro selle adecuadamente en todas partes C MO LIMPIAR EL FILTRO DE LA V LVULA DE COMBUSTIBLE 1 Retire la copa en la parte inf...

Page 33: ...vula de combustible 5 Verifique la integridad de todas las piezas del generador 6 Limpie el carburador SERVICIO POCO FRECUENTE Si la unidad no se utiliza frecuentemente podr an ocurrir dificultades al...

Page 34: ...ema de conducci n Conexi n directa manivela ahusada Capacidad de aceite 0 6 litros 20 oz Buj a Champion RN14YC o equivalente Gobernador Mec nico adjustable Sistema de enfriamiento Enfriamiento forzado...

Page 35: ...el desgaste y el uso normales La garant a no ser v lida si el consumidor no instala da mantenimiento y hace funcionar el producto de acuerdo con las instrucciones y recomendaciones de la Compa a desc...

Page 36: ...36 Customer Hotline 1 800 445 1805 PARTS DRAWING SCHEMA DES PI CES DIAGRAMA DE PIEZAS...

Page 37: ...ge Varilla 1 137 0063100 Spring carburetor Ressort Resorte 1 138 0064795 Bolt M6 x 12 Boulon M6 x 12 Perno M6 x 12 4 139 Note A Fuel tank R servoir de carburant Tanque de metal de combustible 1 140 00...

Page 38: ...028 031 pouces 0 7 0 8 mm AVERTISSEMENT Pour viter toute blessure personnelle ou dommage l quipement l installation et tout entretien devralent tre effectu s par un lectricien qualifi ou un pr pos au...

Page 39: ...be identical in all material respects to the part as described in the engine manufacturer s application for certification The ECS Warranty only pertains to emissions related parts on your engine as f...

Page 40: ...mate Corporation All rights reserved Powermate is a registered trademark of Powermate Corporation 2006 Powermate Corporation Tous droits r serv s Powermate est une marque d pos e de Powermate Corporat...

Reviews: