background image

5

20. Keep all electrical appliances such as radios,

telephones, televisions, and lights at least
five feet (1.52 meters) away from the water.

21. A wire connector is provided on the pump

motor of this unit to connect a minimum No.
8 AWG (804 mm

2

) solid copper conductor

between this unit and any metal equipment,
electrical enclosure made of metal, metal
water pipes, or conduit within five feet
(1.52m) of the unit.

22. DANGER—Risk of electric shock: Do not set

up the RESTORATION 600 within five feet of
any metal objects or surfaces. As an alterna-
tive, you may use the spa within five feet of
metal objects if each metal object is perma-
nently connected to the wire connector on
the pump motor of this unit by a minimum
No. 8 AWG (804 mm

2

) solid copper conductor

(see instruction 21). 

23. DANGER—Risk of drowning: Exercise

extreme caution to prevent unauthorized and
unsupervised use of the RESTORATION 600
by children. Children must always be super-
vised.

24. DANGER—To reduce the risk of drowning:

• Never use the spa alone;
• Children should not use the spa unless

they are supervised by an adult;

• Keep pets away from the spa at all times;
• Always replace and lock the spa cover

when the spa is not in use. 

25. WARNING—To reduce the risk of injury: The

water temperature should never exceed
104°F (40°C). Temperatures between 100°F
(38°C) and 104°F (40°C) are considered to be
safe for healthy adults. However, if you plan
to remain in the RESTORATION 600 for more
than 10 to 15 minutes, a lower temperature is
recommended. Lower temperatures are also
recommended for children. 

26. WARNING—To reduce the risk of injury:

Always use an accurate thermometer to
determine the water temperature before
using the RESTORATION 600.

27. WARNING—To reduce the risk of injury:

Pregnant women should consult with their
physician before using the RESTORATION
600. Pregnant women should not use the spa
if the water temperature is above 100°F (38°C);
the unborn child could be seriously harmed. 

28. DANGER—To reduce the risk of drowning:

Prolonged immersion in the RESTORATION
600 may cause hyperthermia, a dangerous
condition which occurs when the internal
body temperature rises several degrees
above the normal body temperature of 98.6°F.
The symptoms of hyperthermia are nausea,
dizziness, drowsiness, and fainting. Effects
include: a lack of awareness, inability to per-
ceive heat or danger, and a greater risk of
drowning due to a loss of consciousness.
Special note: Individuals suffering from
hyperthermia may be unable to realize that
they must exit the spa, and they also may be
physically unable to do so.

29. WARNING—To reduce the risk of drowning:

Heat from the water, in conjunction with alco-
hol or drugs can cause unconsciousness. Do
not use the RESTORATION 600 if you are
under the influence of drugs or alcohol.

30. WARNING—To reduce the risk of injury or

drowning: Consult your physician about pos-
sible side-effects of any medications you may
be taking before using the RESTORATION
600. Heat from the water, in conjunction with
some medications may cause drowsiness
and increase the risk of drowning. Others
can effect blood pressure, heart rate, and cir-
culation.

31. WARNING—To reduce the risk of injury: It is

especially important for persons over the age
of 35 or persons with pre-existing health
problems, such as obesity, heart disease,
high or low blood pressure, circulatory prob-
lems, or diabetes to consult your physician
before using this product. 

32.  If you feel pain or dizziness at any time while

using the RESTORATION 600, discontinue
use and contact a physician.

WARNING: Read all instructions before using the RESTORATION 600. ICON assumes no responsibil-
ity for personal injury or property damage sustained by or through the use of this product. 

SAVE THESE INSTRUCTIONS

Summary of Contents for 831.100400

Page 1: ...OUR TOLL FREE CUSTOMER HOT LINE The trained techni cians on our customer hot line will provide immediate assis tance free of charge to you CUSTOMER HOT LINE 1 888 936 4266 Mon Thu 8 00 am 6 30 pm Fri 8 00 am 6 00 pm EST Model No 831 100400 Serial No Write the serial number in the space above for reference Patent Pending CAUTION Read all precautions and instruc tions in this manual before using thi...

Page 2: ...the spa shell resulting from exposure to extreme temperatures or damage to the spa shell resulting from exposure to direct sun light and ultraviolet rays while the spa is empty damage to the pump motor plumbing and components due to improper maintenance chemical treatment or exposure damage resulting from failure to proper ly follow user s manual installation operating or maintenance instructions ...

Page 3: ...ING A LOCATION FOR THE RESTORATION 600 8 ASSEMBLY 9 USING THE RESTORATION 600 11 MAINTENANCE 14 TROUBLE SHOOTING 15 CUSTOMER RECORD 19 ORDERING REPLACEMENT PARTS Back Cover Note A PART LIST and an EXPLODED DRAWING are attached to the center of this manual Remove the PART LIST and EXPLODED DRAWING before beginning assembly 3 ...

Page 4: ...e any water which may collect on the spa cover 12 Keep children and pets away from the RESTORATION 600 when it is not in use 13 Keep all chemicals away from children and pets 14 The pH and chemical balance of the water must be maintained as explained in this man ual see page 11 Failure to do so may cause injury to users or damage to the spa jet unit and will void the warranty 15 The water pump in ...

Page 5: ...h their physician before using the RESTORATION 600 Pregnant women should not use the spa if the water temperature is above 100 F 38 C the unborn child could be seriously harmed 28 DANGER To reduce the risk of drowning Prolonged immersion in the RESTORATION 600 may cause hyperthermia a dangerous condition which occurs when the internal body temperature rises several degrees above the normal body te...

Page 6: ... 600 Locate the labels and familiar ize yourself with this information The label on the side of the spa jet unit is an adhesive decal If this decal is missing or if it is not legible please call our Customer Service Department toll free at 1 888 936 4266 Monday Thursday 8 00 am 6 30 pm Friday 8 00 am 6 00 pm EST excluding holidays to order a replacement decal Apply the decal in the location shown ...

Page 7: ...RATION 600 If you have additional questions please call our Customer Service Department toll free at 1 888 936 4266 Monday Thursday 8 00 am 6 30 pm Friday 8 00 am 6 00 pm EST excluding holidays To help us assist you please note the product model number and serial number before calling The model number is 830 100400 The serial number can be found on a decal attached to spa jet unit see the front co...

Page 8: ...t there is room around the RESTORA TION 600 to permit servicing of the unit The diameter of the tub is 69 You should allow for this size plus the size of the spa jet unit when choosing the location 8 Be sure to note any other considerations such as aesthetics or privacy concerns that may affect the safety or enjoyment of using the RESTORATION 600 If you set up the RESTORATION 600 outside 1 You sho...

Page 9: ...ith the hole in the Fabric Spa Surround Flip the flap on the Fabric Spa Surround 8 over the low section of the Inflatable Spa Liner 9 Be sure that all six cover buckles are fully inserted through the loops in the Fabric Spa Surround 8 3 Remove the power cord from the Spa Jet Unit 13 With the help of a second person place the Spa Jet Unit 13 over the Fabric Spa Surround 8 and the section of the Inf...

Page 10: ...derside of the Spa Cover 11 See inset drawing A Insert the inflation tube into the hole in the Support Ball 4 Inflate the Support Ball See inset drawing B When the Support Ball 4 is inflated remove the inflation tube from the Support Ball and insert the ball plug through the mesh into the Support Ball The head of the ball plug will hold the Support Ball in place Note The Support Ball 4 is not a to...

Page 11: ...he GFCI before using the RESTORATION 600 First turn on the RESTORATION 600 by pressing the power button on the console Once the unit is run ning press the GFCI test button The RESTORA TION 600 should shut off Press the reset button The RESTORATION 600 should resume normal oper ation If the RESTORATION 600 continues to run after the test button is pressed then the GFCI is dam aged Do not use the RE...

Page 12: ...h of children USING THE CONSOLE Refer to the console diagram above The function of each console control is explained below Primer This opening allows you to prime the spa jet unit before operation see PRIMING THE SPA JET UNIT on page 10 Thermostat Controls the temperature of the water The water heats at about 1 7 F an hour with the cover on The thermostat can be set to heat the water from 70 F to ...

Page 13: ...e pump will begin circulat ing the water for twenty minutes to filter any impuri ties Also if the water temperature falls below 40 F the pump will begin circulating and heating the water to prevent the water from freezing DRAINING THE RESTORATION 600 To drain the RESTORATION 600 you must use a garden hose to siphon the water Place one end of the hose in the spa and hold it in front of a hydro ther...

Page 14: ...mounts follow the directions on the label closely 5 Keep all containers closed tightly when not in use 6 Never add water to the chemicals always add the chemicals to the water as directed 7 Always store chemicals in a cool dry place MAINTAINING THE PROPER PH BALANCE The pH factor is a measure of relative acidity or alka linity in the water It is measured on a scale of 1 to 14 Pure water has a valu...

Page 15: ... the room temperature is maintained at 70 F it will take approximately 20 to 28 hours for the water to reach the set temperature b If you are using the RESTORATION 600 out doors it may take longer for the water to heat See the chart below for the approximate heat ing time Air Temperature Heating Time 70 F 20 to 28 hours 50 F 70 F 1 to 2 days 30 F 50 F 2 to 3 days b If the water still has not heate...

Page 16: ... outdoors in cold weather you must allow the spa to maintain a safe temperature by running in automatic mode Allowing the spa jet unit to freeze will damage the unit If you do not want to use the spa during the winter store it in a warm dry location see WINTER USE AND CARE on page 13 11 SYMPTOM THE WATER LEVEL DROPS a Some water loss due to evaporation is normal If rapid water loss occurs or if yo...

Page 17: ...17 NOTES ...

Page 18: ...NOTES 18 ...

Page 19: ...19 CUSTOMER RECORD Model No Serial No Retailer Name Purchase Date Retailer Address ICON of Canada Inc 900 de l Industrie St Jérôme Québec Canada J7Y 4B8 PLACE STAMP HERE ...

Page 20: ...many times a week do you exercise Less than 3 times 3 times or more 5 Have you ever purchased an ICON product before Yes No 6 Where did you first see or hear about ICON products Magazine Friend relative Newspaper Ad Store Other 7 What was the primary reason for purchasing this ICON product Store Employee Television Ads Colour Electronic Features Magazine Ads Price Product Design Product Innovation...

Page 21: ...81 REMOVE THIS EXPLODED DRAWING FROM THE MANUAL ...

Page 22: ... Electronic Control 26 1 Motor Endcap 27 1 Headrest w Fasteners 28 4 Nut 29 1 Heat Control Nut 30 4 Rubber Insulator Key No Qty Description 31 4 Washer 32 1 Primer O ring 33 1 Rubber Damper 34 1 Wire Harness 35 1 Air Control Knob 36 1 On Off Switch Assembly 37 1 Thermostat Knob 38 1 Primer Cap 39 16 Housing Screw 40 1 Console Overlay 41 1 Micro Switch Wire 42 2 Control Mounting Screw 43 2 Control ...

Page 23: ... 27 26 33 28 30 31 7 10 1 49 48 38 32 36 35 37 29 17 18 19 42 43 41 44 45 46 50 40 47 15 39 39 12 5 5 6 6 14 21 8 23 24 3 34 48 2 4 51 11 EXPLODED DRAWING Model No 831 100400 R0398A SCHÉMA DÉTAILLÉ No du Modéle 831 100400 ...

Reviews: