USING THE HYDROTHERAPY SPA

The hydrotherapy spa is designed to seat five adults.
The ten thera-jets can be regulated to provide a relax-
ing massage to sooth away stress, and the strength
of the water massage can be adjusted by the air con-
trol. The hydrotherapy spa holds 200 gallons of water
and offers an automatic, programmable heating (41°F
to 104°F) and filtration system. 

The guidelines below explain how to properly use the
hydrotherapy spa. Follow these guidelines to maintain
the hydrotherapy spa for your long-term enjoyment.

PLUGGING IN THE HYDROTHERAPY SPA

Once the hydrotherapy spa is filled with water and
you have made sure that the cut-off valves to the
pump are open
, the power cord can be plugged in
and the spa can be turned on. Note: The first time the
power cord is plugged in, the spa will turn on auto-
matically.

When connecting the power cord, plug the power cord
directly into a grounded circuit capable of carrying 15
or more amps. No other appliance should be on the
same circuit. Replace the power cord immediately if it
becomes damaged.

The power cord is equipped with a Ground Fault
Circuit Interrupter (GFCI), located at the end of the
power cord. You should always test the GFCI before
using the hydrotherapy spa.  

First, turn on the hydrotherapy spa by pressing the
power button on the console. Once the unit is run-
ning, press the GFCI “test” button. The hydrotherapy
spa should shut off. Press the “reset” button. The
hydrotherapy spa should resume normal operation. If
the hydrotherapy spa continues to run after the “test”
button is pressed, then the GFCI is damaged. Do not
use the hydrotherapy spa until the GFCI has been
repaired or replaced by a qualified electrician.

TESTING AND TREATING THE WATER

The hydrotherapy spa comes with a starter chemical
pack for maintaining the water in the spa. Disregard
the directions on the individual packages of “QUICK
pHix It DOWN” and “QUICK pHix It UP.” However, the
directions on the bottle of “Non-chlorine Shox” and
“Bromine Base” are correct. Always keep the chemi-
cals away from children and pets.

The first time you use the spa, you should test and
treat the water. You must also treat the water each
time you refill the spa. 
Once you have verified that
the spa is functioning properly, and the water has cir-
culated for a while, remove the spa cover and add 1/3
of the “Bromine Base” bottle, and 1/3 of the “Non-
chlorine Shox” bottle to the water. Allow the water to
circulate for five minutes. You should now test the pH
of the water. You will need a pH test kit (not included),
which can be obtained at a pool and spa supply store.
The pH reading should be between 7.2 and 7.8. 

If the level is too low, add half of one of the “QUICK
pHix It UP” packets to the water. Let the water circu-
late through the spa for five minutes. Test the pH level
again. Repeat until the pH level is correct.

If the level is too high, add half of one of the “QUICK
pHix It DOWN” packets to the water. Let the water cir-
culate through the spa for five minutes. Test the pH
level again. Repeat until the pH level is correct.

See WATER CHEMISTRY on page 17 for information
concerning proper water maintenance.

STARTING THE HYDROTHERAPY SPA

Once you have tested the GFCI, you should verify the
water flow from the pumping unit. Set the air control
on the console to the lowest setting (see USING THE
CONSOLE on page 13). The pumping unit will heat
the water as it pumps. Cover the hydrotherapy spa
with the spa cover. The spa cover must be tight.
(See SECURING THE SPA COVER on page 14.) The
water will heat at about 2.0°F an hour with the cover
on. If you are using the spa indoors, and the room
temperature is maintained at 70°F, it will take approxi-
mately 24 to 26 hours for the water to reach the set
temperature.

The temperature and water flow can be set or
changed by the controls on the console (see USING
THE CONSOLE on page 13).

Test and Reset

Buttons

Grounded circuit

capable of carrying

15 or more amps

GFCI

Summary of Contents for 831.100420

Page 1: ...manual for future reference SEARS CANADA INC TORONTO ONTARIO M5B 2B8 QUESTIONS PLEASE CALL DIRECT TO OUR TOLL FREE CUSTOMER HOT LINE The trained technicians on our customer hot line will provide immediate assistance free of charge to you CUSTOMER HOT LINE 1 888 936 4266 Mon Thu 8 00 am 6 30 pm Fri 8 00 am 6 00 pm EST Hydrotherapy Spa Model No 831 100420 Serial No Write the serial number in the spa...

Page 2: ...tment damage to the spa shell resulting from exposure to extreme temperatures or damage to the spa shell resulting from exposure to direct sun light and ultraviolet rays while the spa is empty damage to the pump motor plumbing and components due to improper maintenance chemical treatment or exposure damage resulting from failure to proper ly follow user s manual installation operating or maintenan...

Page 3: ...PORTANT SAFETY INSTRUCTIONS 4 BEFORE YOU BEGIN 7 CHOOSING A LOCATION FOR THE HYDROTHERAPY SPA 8 SET UP AND ASSEMBLY 9 USING THE HYDROTHERAPY SPA 11 MAINTENANCE 16 TROUBLE SHOOTING 20 PART LIST 22 EXPLODED DRAWING 23 CUSTOMER RECORD 25 ORDERING REPLACEMENT PARTS 26 ...

Page 4: ...is empty The surface of the spa shell can reach temperatures as high as 150 F in a matter of minutes if exposed to the sun while it is empty These high temperatures can cause significant damage such as blistering of the shell surface and warping of the spa shell Any damage caused by sun exposure is not covered under warranty 9 Do not bring any object into the hydrothera py spa that could damage th...

Page 5: ... hydrotherapy spa by children Children must always be super vised 28 DANGER To reduce the risk of drowning Never use the hydrotherapy spa alone Children should not use the hydrotherapy spa unless they are supervised by an adult Keep pets away from the hydrotherapy spa at all times Always replace and lock the spa cover when the hydrotherapy spa is not in use 29 WARNING To reduce the risk of injury ...

Page 6: ...ysician 37 WARNING To reduce the risk of injury It is especially important for persons over the age of 35 or persons with pre existing health problems such as obesity heart disease high or low blood pressure circulatory prob lems or diabetes to consult their physician before using this product 38 The included warning sign must be posted where all users of the spa can see and read it see POSTING TH...

Page 7: ...ORA TION 510 hydrotherapy spa gives you the specialized treatment you need to feel your best For your safety and benefit read this manual care fully before using the PROFORM RESTORATION 510 If you have additional questions please call our Customer Service Department toll free at 1 888 936 4266 Monday Thursday 8 00 am 6 30 pm Friday 8 00 am 6 00 pm EST excluding holidays To help us assist you pleas...

Page 8: ...eck system that is built flush with the top of the spa provided you leave access to the motor for ser vice 9 Be sure to note any other considerations such as aesthetics or privacy concerns which may affect the safety or enjoyment of using the hydrotherapy spa If you set up the hydrotherapy spa outside 1 You should check your local building codes con cerning the use of outdoor spas 2 The location m...

Page 9: ... from the access cover Remove the access cover from the Spa Unit 15 by sliding the access cover down and pulling the bottom of access cover away from the Spa Unit Be careful not to damage the spa shell Remove the Power Cord with the GFCI 36 from inside the Spa Unit 15 2 Locate and check the position of the cut off valves Occasionally the valves will be closed at the factory during manufacturing Th...

Page 10: ...Be sure that the Spa Cover is properly centered Snap a Buckle 2 onto each of the four latches on the Spa Cover 18 See the inset drawing Position one of the Buckles 2 on the wood panels on the Spa Unit 15 Hold the Buckle in place so the strap on the Spa Cover 18 is tight Note It may be easier to position the Buckle if a second person holds the strap on the opposite side of the Spa Cover tight The S...

Page 11: ...ackages of QUICK pHix It DOWN and QUICK pHix It UP However the directions on the bottle of Non chlorine Shox and Bromine Base are correct Always keep the chemi cals away from children and pets The first time you use the spa you should test and treat the water You must also treat the water each time you refill the spa Once you have verified that the spa is functioning properly and the water has cir...

Page 12: ...ge on your lower or middle back The remaining jet located on the other bench seat focus es the water massage on your upper or lower back The filter C can be removed for replacement and cleaning see page 16 The suction vents D located near the floor of the spa bring the water into the pump in order to operate the system The suction covers should always be in place over the suction vents Never opera...

Page 13: ...rn off and the display will return to the actual water temperature The water heats at about 2 0 F an hour with the cover on Filter On This LED indicator is lit when the spa is running the filter cycle The length and number of filter cycles can be adjusted see page 14 Heat On This LED indicator is lit when the spa is run ning the heating cycle Note To keep the heat and filter cycles from run ning t...

Page 14: ...ill appear in the temperature display Use the up and down buttons to select the desired cycle length The pump or the light may turn on while you are adjusting the filter cycle If this happens you can turn the pump or light off once you have finished the adjustment procedure SECURING THE SPA COVER The spa cover can be secured by snapping the latches on the spa cover into the buckles on the side pan...

Page 15: ...ARNING SIGN The Warning Sign shown below must be posted on a wall or fence where all users of the hydrotherapy spa will be able to see it Whenever the spa is moved the sign must also be moved and reposted near the spa ...

Page 16: ...in your climate CLEANING THE SPA SHELL The spa shell should be cleaned with a mild soap solution Do not use solvents The spa should always be clean and dry before being moved or stored MAINTAINING THE SPA COVER The spa cover should be cleaned monthly To clean the spa cover use water and a non abrasive cleaner on the entire cover Rinse the cover with a garden hose to remove any cleaner residue Dry ...

Page 17: ...lems can occur when the pH balance is not maintained within this range If the pH level exceeds 7 8 dissolved minerals can build up and clog the plumbing in the spa jet unit If the pH level falls below 7 2 the acid level in the water will begin to cor rode the metal parts in the spa jet unit Also the sani tation agents in the water will not be effective if the pH level is not properly maintained Da...

Page 18: ...drained if the spa will be stored for more than thirty days or if it may be exposed to freezing temperatures To drain the pump remove the access cover from the spa unit see ATTACHING AND REMOVING THE ACCESS COVER on page 17 Locate the pump inside the spa unit Remove the drain plug from the pump Tip the spa jet unit slightly until all the water has drained from the pump Replace the drain plug OPENI...

Page 19: ...ned to operate with either a 120v or 240v power source For your conve nience it is shipped ready to be plugged directly into a 120v 15 amp home outlet However you can greatly improve the performance of the spa by converting the spa s power supply to receive power from a 240v power source If the spa is converted it must be wired directly into a 240v GFCI in your home by a qualified electrician You ...

Page 20: ...may also con tact a local spa and pool service provider 6 SYMPTOM THE WATER DOES NOT HEAT a Make sure that the hydrotherapy spa is fully covered with the spa cover The spa cover must be tight for the water to heat Set the air control to low Set the temperature to the desired setting The water will heat at a rate of 2 0 F an hour If you are using the spa indoors and the room temperature is maintain...

Page 21: ...ump compart ment for excess water and watch the pump unit while it is operating to see if water drips from any of the plumbing If you can identify the location of the leak inside the spa jet unit tight en the clamp or replace the damaged seal 10 SYMPTOM THE SPA CONTINUES TO RUN AFTER IT HAS BEEN SHUT OFF a To turn the spa jets on press the Pump button once To turn the spa jets off press the contro...

Page 22: ...ontrol Knob 18 1 Spa Cover 19 1 Rubber Gasket 20 2 6 Lock Washer 21 1 Sensor Fitting Assembly 22 1 Heater Switch 23 1 Hose Washer 24 1 Drain Plug Key No Qty Description 25 1 1 2 O ring 26 3 Rubber Washer 27 1 Suction Cover 28 1 Cover Screw 29 1 Console Bracket 30 2 Wing Nut 31 1 Wire Harness 32 4 Small Star Washer 33 1 Red Lens 34 4 Heater Control Screw 35 3 Multidirectional Jet 36 1 Power Cord w ...

Page 23: ...1 2 2 10 15 16 17 18 36 27 28 35 35 7 8 19 35 26 14 32 34 34 32 32 22 11 23 6 33 9 21 3 4 5 12 13 25 24 31 30 29 38 3 37 37 39 20 20 EXPLODED DRAWING Model No 831 100420 R0398B 23 ...

Page 24: ...NOTES 24 ...

Page 25: ...25 CUSTOMER RECORD Model No Serial No Retailer Name Purchase Date Retailer Address ICON of Canada Inc 900 de l Industrie St Jérôme Québec Canada J7Y 4B8 PLACE STAMP HERE ...

Page 26: ... magazines do you read regularly Sports Fitness Motoring Business Computer General 12 Do you wish to be sent further bulletins about ICON products Yes No THANK YOU FOR YOUR TIME o f d u C a n a d a I n c PRODUCT WARRANTY REGISTRATION 1998 ICON of Canada Inc Printed in USA Model No 831 100420 QUESTIONS As a manufacturer we are commit ted to providing complete cus tomer satisfaction If you have ques...

Reviews: