22
MAINTENANCE
Regular maintenance is important for optimal
performance and to reduce wear. Inspect and properly
tighten all parts each time the trainer is used. Replace
any worn parts immediately.
To clean the trainer, use a damp cloth and a small
amount of mild soap. IMPORTANT: To avoid damage
to the console, keep liquids away from the console
and keep the console out of direct sunlight.
CONSOLE TROUBLESHOOTING
If the console does not turn on, make sure that the
power adapter is fully plugged in.
If the console does not display your heart rate when
you hold the handgrip heart rate monitor, or if the dis-
played heart rate appears to be too high or too low, see
step 5 on page 17.
If a replacement power adapter is needed, call the
telephone number on the cover of this manual.
IMPORTANT: To avoid damaging the console, use
only a manufacturer-supplied regulated power
adapter.
HOW TO ADJUST THE REED SWITCH
If the console does not display correct feedback, the
reed switch should be adjusted. To adjust the reed
switch, first unplug the power adapter.
Next, remove the
four indicated
M4 x 16mm Flat
Head Screws
(101) and the
Lower Rear
Shield Cover
(68).
Next, turn the Large Pulley (21) until a Pulley Magnet
(121) is aligned with the Reed Switch (116). Then,
loosen, but do not remove, the M4 x 19mm Screw
(113), slide the Reed Switch slightly closer to or away
from the Pulley Magnet, and retighten the Screw.
Then, plug in the power adapter and turn the Large
Pulley (21) for a moment. Repeat these actions, if
necessary, until the console displays correct feedback.
Then, reattach the lower rear shield cover.
113 116
121
21
MAINTENANCE AND TROUBLESHOOTING
101
101
101
Summary of Contents for CARDIO HIT
Page 26: ...26 NOTES ...
Page 27: ...27 NOTES ...