background image

2

 

 

 

These symbols are intended to alert the user to the presence of 

important operating and maintenance instructions in the manual 

accompanying the appliance.

RETAIN THIS MANUAL FOR FUTURE REFERENCE

NOTICE

Using  any  part  other  than  genuine  Star  factory  supplied  parts  relieves  the 

manufacturer of all liability.
Star  reserves  the  right  to  change  specifi cations  and  product  design  without 

notice.    Such  revisions  do  not  entitle  the  buyer  to  corresponding  changes, 

improvements,  additions  or  replacements  for  previously  purchased 

equipment.
Due  to  periodic  changes  in  designs,  methods,  procedures,  policies  and 

regulations, the specifi cations contained in this sheet are subject  to change 

without notice.  While Star Manufacturing exercises good faith efforts to provide 

information  that  is  accurate,  we  are  not  responsible  for  errors  or  omissions 

in  information  provided  or  conclusions  reached  as  a  result  of  using  the 

specifi cations.  By using the information provided, the user assumes all risks in 

connection with such use.

MAINTENANCE AND REPAIRS

Contact your local dealer for service or required maintenance.  Please record the model number, serial 

number, voltage and purchase date in the area below and have it ready when you call to ensure a faster 

service. 

 

SAFETY SYMBOL

Model No.

Serial No.

Voltage

Purchase Date

FOR SERVICE CONTACT:

Servequip

Telephone:

 

0-44-08686-8855

Summary of Contents for GR10T4K-CE

Page 1: ... TABLE TOP TWO SIDED TOASTER MODEL GR10T4K UK GR10T4K CE Installation and Operation Instructions 2M Z9364 Rev A 1 31 2011 ...

Page 2: ...dures policies and regulations the specifications contained in this sheet are subject to change without notice While Star Manufacturing exercises good faith efforts to provide information that is accurate we are not responsible for errors or omissions in information provided or conclusions reached as a result of using the specifications By using the information provided the user assumes all risks in...

Page 3: ... internal packaging materials for inspection The carrier will make an inspection and will supply necessary claim forms VENTILATION AND CLEARANCES The installation of any components such as a vent hood grease extractors and or fire extinguishing systems must conform to their applicable nationally recognized installation standards and or local building codes ELECTRICAL CONNECTION CAUTION Before maki...

Page 4: ...3 200 F 93 C 4 250 F 121 C 5 300 F 148 C 6 350 F 176 C 7 400 F 204 C 8 450 F 232 C 9 500 F 260 C 10 550 F 287 C PROGRAMMING THE TIMER The timer may be factory pre set If changes are required follow these steps 1 Press and hold the PGM button located on the left side of the display 2 Press and hold one of the buttons 1 through 4 that needs to be programmed After approximately 1 second the display w...

Page 5: ...tton 1 through 4 used to start the countdown NOTE If one wants to end a countdown the same button 1 through 4 can be pressed at any time in the countdown cycle The display will return to the programmed time for that button 7 Raise the lid to the open position and remove the product s 8 For best performance keep the lid closed when products are not being cooked OPERATING HINTS AND SAFETY Disconnect...

Page 6: ...ildupoccurs useacarbonremovalagentaccordingtotheinstructionsprovided with the cleaner When this process is complete you must re season the grill according to your company corporate guidelines or the seasoning instructions in this manual CAUTION DO NOT IMMERSE OR LET THE UNIT STAND IN WATER DO NOT HOSE DOWN THE UNIT OR THE TABLE COUNTER ON WHICH THE UNIT IS LOCATED KEEP AWAY FROM RUNNING WATER CAUT...

Page 7: ...rrect position 4 Check that the thermostat is set to the proper temperature B The top platen is not heating 1 Check that the switch is in the correct position C The counter balance roller is not rolling 1 Clean the rollers If the unit still does not operate contact the factory one of its authorized representatives or a local service company for service or required maintenance ...

Page 8: ...ve cleaners This warranty does not apply to the non stick properties of such materials This warranty is not valid on Conveyor Ovens unless a start up check out has been performed by a Factory Authorized Technician In order to make a claim under this warranty a warranty report must be filed with Star Manufacturing International Inc in St Louis Missouri U S A by the dealer distibutor through which pr...

Page 9: ...TRANSFORMER TERMINAL BLOCK FOR REFERENCE WIRING DIAGRAM IS SHOWN AS UNIT IS ASSEMBLED WITH THE BOTTOM PLATE REMOVED ITEMS ARE IN GENERAL LOCATION BUT MAY BE RELOCATED OR SCALED FOR CLARITY 8 8 1 1 11 12 12 11 5 2 5 2 4 4 10 10 9 9 13 3 3 7 6 7 INDICATOR LIGHT POWER ON TIMER BOARD SWITCH THERMOSTAT BOTTOM ELEMENT 20 19 18 G UNITS WITH IEC CONNECTOR POWER INLET CONNECTOR IEC 320 C 20 POWER INLET ON ...

Page 10: ...TOCA R CALI ENTE PR EC AU CIO N Maint engas e lejos de ma ng ue ra No roc ia con o dejar que la base este estan cada sobre agua Favo rde no sume rgir Do not hose down Do not imme rse or let CA UT IO N base stand in wate r 11 13 10 9 12 1 43 5 40 7 2 4 8 18 19 39 20 21 22 44 23 24 25 26 37 49 33 27 27 29 30 31 3 6 17 52 51 46 45 50 47 48 NAMEPLATE 55 54 53 STAR MANUFACTURING INTERNATIONAL INC CERTA...

Page 11: ...0V 6VA 21 2R Z2907 1 COUNTER BALANCE 10 IRON 22 D9 Z2774 1 BOTTOM INSULATION RETAINING PLATE 10 23 D9 Z2908 1 INSULATION 10 24 D9 Z2773 1 BOTTOM ELEMENT RETAINING PLATE 10 25 2N Z2020 1 ELEMENT HEATING 1000W 240V BOTTOM 230V 26 2F Z1929 1 CASTING SMOOTH BOTTOM 10 ALUMINUM 27 D9 Z2772 1 TOP ELEMENT INSULATED PLATE 10 28 D9 GR0084 1 TOP RETAINING PLATE ASSEMBLY 10 29 B9 04 WB 0046 1 CLAMP WIRE SUPPO...

Page 12: ...STAR INTERNATIONAL HOLDINGS INC COMPANY Star Holman Lang Wells Bloomfield Toastmaster 10 Sunnen Drive St Louis MO 63143 U S A 314 781 2777 www star mfg com ...

Reviews: