background image

8347015 

24 IN. DIGITAL LEVEL 

V1.0 

For technical questions call 1-800-665-8685 

 

SPECIFICATIONS 

Material 

Aluminum and ABS 

Length 

24 in. 

Measuring Range 

0 to 360° (0 to 90 Quadrants) 

Digital 

Accuracy 

Level and Plumb 

±0.1°  

Between 1° to 89°  ±0.2° 

Bubble Levels 

(Vials) 

Number 

2 (0° and 90°) 

Accuracy 

0.57° (1.0 in./ft) 

Shock Resistance (Drop) 

Up to 3 feet (1 m) on concrete 

Water Resistance 

Water Resistant 

Operating Temperature 

32 to 104 °F (0 to 40 °C)  

Storage Temperature 

50 to 176 °F (10

 to 

80 °C)  

Batteries 

Type 

3V DC AAA, 2 pc 

Charge Duration 

Approx. 20 Hours with 

Backlight. 

INTRODUCTION 

Measures level, plumb and any angle from 0° through 90°. Easy 

read backlit LCD screen. Ergonomic rubber grip handles. Shock 

absorbing rubber endcaps. 

SAFETY 

WARNING! Read and understand all instructions before using 

this tool. The operator must follow basic precautions to reduce 

the risk of personal injury and/or damage to the equipment. 

 

 

24 IN. DIGITAL LEVEL 

 

Summary of Contents for 8347015

Page 1: ...V1 0 8347015 Please read and understand all instructions before use Retain this manual for future reference USER MANUAL 24 IN DIGITAL LEVEL ...

Page 2: ...Resistance Water Resistant Operating Temperature 32 to 104 F 0 to 40 C Storage Temperature 50 to 176 F 10 to 80 C Batteries Type 3V DC AAA 2 pc Charge Duration Approx 20 Hours with Backlight INTRODUCTION Measures level plumb and any angle from 0 through 90 Easy read backlit LCD screen Ergonomic rubber grip handles Shock absorbing rubber endcaps SAFETY WARNING Read and understand all instructions b...

Page 3: ...ractice that could result in severe personal injury or death if the proper precautions are not taken CAUTION This notice indicates a potentially hazardous situation that may result in minor or moderate injury if proper practices are not taken NOTICE This notice indicates that a specific hazard or unsafe practice will result in equipment or property damage but not personal injury WORK AREA 1 Operat...

Page 4: ... better control in unexpected situations SPECIFIC SAFETY PRECAUTIONS WARNING DO NOT let comfort or familiarity with product gained from repeated use replace strict adherence to the tool safety rules If you use this tool unsafely or incorrectly you can suffer serious personal injury 1 Use the correct tool for the job This tool was designed for a specific function Do not modify or alter this tool or...

Page 5: ...ist are included Contents Digital Level IDENTIFICATION KEY A End Cap B Hanging Hole C Vertical Bubble D Ergonomic Handle E Calibration Button F Reference Button G Measurement Button H LCD I Power Button J Hold Button K Buzzer Backlight Button L Horizontal Bubble OPERATION Letter references in parenthesis A refer to the included Identification Key KEY FUNCTIONS Power Press the button I and hold to ...

Page 6: ...l is in Reference mode Calibrate Recalibrate the level if it is dropped suffered an impact or you suspect it is inaccurate Place the level on a flat surface Press and hold the Calibrate button E until CAL 1 appears Press Calibrate again and the 1 will flash When the number 1 changes to a 2 flip the level upside down and place on the same surface Press Calibrate again The number 2 will flash and tu...

Page 7: ...ewer problems WARNING Only qualified service personnel should repair the tool An improperly repaired tool may present a hazard to the user and or others CLEANING Dirt or moisture may collect on the display during use outdoors Remove any moisture or dirt with a soft dry cloth DISPOSAL Recycle a tool damaged beyond repair at the appropriate facility Contact your local municipality for a list of disp...

Page 8: ...8347015 24 IN DIGITAL LEVEL V1 0 8 For technical questions call 1 800 665 8685 ...

Page 9: ...V 1 0 8347015 Vous devez lire et comprendre toutes les instructions avant d utiliser l appareil Conservez ce manuel afin de pouvoir le consulter plus tard MANUEL D UTILISATEUR NIVEAU NUMÉRIQUE DE 24 PO ...

Page 10: ... 0 po pi Résistance aux impacts lors d une chute Jusqu à 1 m 3 pi sur le béton Résistance à l eau Résistant à l eau Température de fonctionnement 32 à 104 F 0 à 40 C Température d entreposage 50 à 176 F 10 à 80 C Piles Type 3 V c c AAA 2 pièces Durée de la charge Environ 20 heures avec rétroéclairage INTRODUCTION Mesure le niveau l aplomb et tout angle de 0 à 90 Écran ACL rétroéclairé facile à lir...

Page 11: ...e respecte pas certaines instructions DANGER Cet avis indique un risque immédiat et particulier qui entraînera des blessures corporelles graves ou même la mort si on omet de prendre les précautions nécessaires AVERTISSEMENT Cet avis indique un risque particulier ou une pratique non sécuritaire qui pourrait entraîner des blessures corporelles graves ou même la mort si on omet de prendre les précaut...

Page 12: ...e protection des yeux devrait être conforme à la norme CSA Z94 3 07 ou ANSI Z87 1 fonction du type de travail effectué 2 Portez des gants qui protègent en fonction des matériaux de travail et pour réduire les effets des vibrations de l outil PRÉCAUTIONS PERSONNELLES Gardez le contrôle de l outil de vos mouvements et de l environnement de travail pour éviter les blessures ou le bris de l outil 1 N ...

Page 13: ...s températures élevées Le boîtier et certaines pièces internes sont fabriqués de plastique et pourraient se déformer à des températures élevées 4 NE RANGEZ PAS le niveau dans un environnement froid L humidité peut apparaître sur les pièces intérieures lors du réchauffement Cette humidité pourrait entraîner la corrosion des cartes de circuits imprimés internes 5 Retirez les piles lorsque vous range...

Page 14: ...dentification comprise FONCTIONS CLÉS Mise en marche Appuyez sur le bouton I et maintenez le enfoncé pour placer le niveau sous tension et hors tension Maintenir Appuyez sur le bouton J pour conserver la lecture actuelle La lettre H clignote lorsque la lecture est maintenue Appuyez de nouveau sur le bouton de maintien pour annuler la fonction Avertisseur sonore rétroéclairage Appuyez sur le bouton...

Page 15: ...L 1 apparaisse Appuyez de nouveau sur le bouton de calibrage et le 1 clignotera Lorsque le chiffre 1 est remplacé par un 2 retournez le niveau et placez le sur la même surface Appuyez de nouveau sur le bouton de calibrage Le chiffre 2 clignotera et sera remplacé par un angle actif Ainsi se termine l étalonnage Température Appuyez brièvement sur le bouton de calibrage pour afficher la température d...

Page 16: ...ter un risque pour l utilisateur et ou pour les autres NETTOYAGE La saleté ou l humidité peut s accumuler sur l affichage lorsqu on utilise le niveau à l extérieur Éliminez toute trace d humidité ou de saleté au moyen d un chiffon propre et sec MISE AU REBUT Recyclez votre outil endommagé dans une installation prévue à cet effet s il est impossible de le réparer Communiquez avec votre municipalité...