background image

  1

 

*****CM 5000D CURTAIN-MINDER INSTRUCTIONS***** 

 

1

- Unpack your 

CM 5000D

 Curtain-Minder.  Remove the transformer and the winch kit. 

 
2- The transformer mounts on a 7/8" knock out of a junction box, handy box, or breaker panel.  It is 
best to wire the primary wire leads of the transformer to a fan power supply circuit, preferably the 
workhorse fan breaker. 
 
3- Mount the 

CM 5000D

 Curtain-Minder on the wall so the white wires will reach the transformer.  

Connect the white lamp cord from the 24 VAC terminals of the Curtain-Minder to the screw 
terminals on the transformer.  Apply power to the unit and see that the 

AC POWER

 light is on.  

Disconnect the power and continue the installation.  
 
4- You have two reliable choices for installing the Winch Kit(s).  The parts are included for both. 
     
   (A) The 

DIRECT-CONNECT

 method (Page 7, Figure 1A), eliminates the loss of the braided 

cord with the handle hook.  The cord is tied above and to one side of the winch kit so the winch kit 
can swing out of the way of the winch handle.  To operate, the winch kit is closed so the hinge 
meets the blue electro-magnet.  The string loop (with the HANDLE HOOK) is draped over the 
hinge.  Make sure the loop drapes over the knuckle of the hinge and does not make contact with the 
tilt screw.  Now let the winch handle cradle in the handle hook.  You may prefer to crimp the 
handle hook to the winch handle to prevent it from getting lost.   
 
   (B) The 

ORIGINAL

 method (Page 7, Figure 1B) provides good holding power, especially when 

curtain machines are used.  Mount the winch kit on a mounting surface as near the winch handle as 
possible, using the holes in the top of the plate.  The hinge, when open, should point toward the 
winch handle.  Make sure the tilt screw is in enough for the hinge to contact the magnet.  Remove 
the handle hook from the short loop by cutting or untying the cord.  Cut a piece of PVC pipe nearly 
as long as the cord.  Thread the looped end of the cord through the piece of PVC pipe.  Refer to 
Figure 1B.  Drape the looped end of the braided cord over the hinge so that it rests at the knuckle of 
the hinge.  Keeping the cord as short as possible, tie the handle hook on the other end of the cord 
and cradle the winch handle in the handle hook.  Remove the ratchet on the winch!  Now the winch 
kit is carrying the weight of the winch handle.  When you positively do not want to release the 
winch handle, let the hinge hang down and connect the looped end of the cord to the tilt screw. 
  
5- You should use 18-gauge two-conductor lamp cord to make all of your connections.  Other wire 
may not be as satisfactory in the long run.  

 

6- There are six terminal blocks with four screw terminals each on the right side of the front door 
for all of the wiring connections.  The terminal blocks can be unplugged for easy access.  The 
second through the fifth terminal block is used to wire the winch kits.  The fifth terminal block is 
labeled 

Magnet 1

 and the second terminal block is labeled 

Magnet 4

.  There is no particular order 

for numbering the winch kits.   
 
The 

CM 5000D

 will accommodate up to five winches.  There is a small yellow screwdriver 

included for making the connections.  Please leave the screwdriver inside the Curtain-Minder! 

 

Summary of Contents for CM 5000D

Page 1: ...el IN A HURRY Flip to Pages 6 13 for Wiring Diagrams 4 11 PRO TECH INC 1256 N Barkley Rd Statesville NC 28677 Phone 704 872 6227 Fax 980 223 2872 www pro techinc com Email sales pro techinc com Copyright by Pro Tech Inc 2004 All rights reserved ...

Page 2: ...s are used Mount the winch kit on a mounting surface as near the winch handle as possible using the holes in the top of the plate The hinge when open should point toward the winch handle Make sure the tilt screw is in enough for the hinge to contact the magnet Remove the handle hook from the short loop by cutting or untying the cord Cut a piece of PVC pipe nearly as long as the cord Thread the loo...

Page 3: ... safety attach it near the curtain winch Being near the winch can be very hazardous so STAY CLEAR 7 The CM 5000D has a relay with a dry contact that can be tied to your alarm to tell you when the unit has detected low power There are three terminals at the top of the board see Figure 3 for this output The alarm can be wired Normally Open NO or Normally Closed NC 8 Remove the green paper from the d...

Page 4: ...e reed switch wires Connect the other end of the black and white wires to the six screws labeled Reed Switch 1 Reed Switch 2 and Reed Switch 3 Extend the magnet wires with the red and green conductor Connect the green wires to the bottom screws labeled Magnet 1 Magnet 2 and Magnet 3 Connect the red wire of the 1st and 2nd magnet to the top screws labeled Magnet 1 and Magnet 2 Connect the red wire ...

Page 5: ...0D Curtain Minder is only a management tool and NOT an insurance policy It does not replace the attendant or make a poor attendant a good one For MAXIMUM PROTECTION make sure that A The ratchet is removed B The weight of the winch handle is sufficient to flip the hinge completely down C The curtains will fall when the winch handle is released NEED MORE STRENGTH There are two ways 1 The Winch Kit h...

Page 6: ...en Siren will alarm when curtains fall or Power Fail Jumper wire from 12V to Common Connections for a CM 5010D to be used as a stand alone alarm system Normally Open Contacts To Trip Siren Can Monitor High Low Temp Water Pressure or any Normally Open Device 6 16 VDC DD 3E DIGITAL DIALER zones _ 1 2 3 4 R EG T TD RD OPE R OU T T RIP R ET UR N OPE R LED Phone Line connection House Phone 2 Amp Min 12...

Page 7: ...6 ...

Page 8: ...7 ...

Page 9: ...m Connect the alarm contacts labeled COM and either the N C or N O terminal to your alarm system The N C is used for Normally Closed and the N O is used for Normally Open You can make the winch kits stronger by moving J4 to the top 2 pins when no more than 4 Winch Kits are used DIP Switches 8 ...

Page 10: ...9 ...

Page 11: ...10 ...

Page 12: ...11 ...

Page 13: ...12 ...

Page 14: ...e to state 1256 N Barkley Rd Statesville NC 28677 704 872 6227 WARNINGS T O RE DUCET HER ISKOFFIR EORELE CT RIC S HOCK DO NOTEXPOS ETHISPR ODU CTT O RAIN OR MOIS TU R E T O RE DUCET HER ISKOFELE CT RIC S HOCK DO NOT OPEN T HISCOVERWIT HOUTDISCONNECTING POWER WHEN T HISUNITISUS ED IN A LIFES UPP OR T VENT ILAT ION SY S TE M WHE REFAILU RECOULD R ESU L TIN L OS SORINJUR Y T HEUS ERS HALL PR OVIDEADE...