5 Err 16 Date or Time is illegal, please input right time and date.
6 Err 09 This truck No does not exist.
7 Err 10 The truck No. stored exceeds 1000.
8 Err 28 printing date is smaller than stored weighing record’s date. Please
delete the larger date record or revise current date and let it not smaller than stored
weighing record’s date.
III. Wrong connection information indicating
1 Err P It means the printer has trouble or wrongly connected. Press any key to
quit. Reconnect the printer or change the printer.
2 Err 01 It means the load cell signal line is wrongly connected, or its signal is
negative or exceeds the range our indicator’s input signal.
(
1
)
If this scale is in working (previous working good), then can judge that the
wire connection is malfunction or load cell is damaged.
(
2
)
If this scale hasn’t been calibrated, the user should check the load cell’s
connection wires is correctly connected or load is working properly.
3. Err 02 It means the load cell’s wires are wrongly connected, or the signal value
exceeds the A/D converting range.
(
1
)
If this scale is in working (previous working good), then can judge that the
wire connection is malfunction or load cell is damaged.
(
2
)
If this scale hasn’t been calibrated, please check as following:
a)
Check the load cell’s connection wires is right or not carefully.
b)
Check if load cell is suitable or not: It should satisfy the following terms:
The load cell’s empty scale loading c scale’s capacity
<
load cell’s
capacity.
4. Err 05 : AD works in false.
1)
If 4-pin shielded cable is applied, please check if you had
short-connected the +E and +S, -E and -S.
2)
Please check if the connection of load cell is correct.
IV. Error of components and solving method
1 Err 18 Key board has problems, It will indicates for ten seconds, then
indicator enters weighing mode. Change the keypad.
2 Err 20 The data is partly lost in RAM. Operator should switch the calibration on
and restart the indicator to self-check. If there is no Err 20, then switch the calibration off.
3 Err 21 Calibrating data have been lost in RAM and EPROM, Operator must plug