Select 

F or C 

with the jumper pin

Select 

ELEC or GAS 

with this switch

Select delay 

ON or OFF

with the jumper pin

Reset button

Delay

The compressor delay will not allow the 
compressor to be turned on for 5 minutes 
after the last time the compressor was  
on.  The cooling icon will flash during the 
delay period.  Select 

OFF or ON with the 

jumper pin as desired.  

Summary of Contents for T601-2

Page 1: ...01 2 U S Registered Trademark Patents pending Copyright 2010 Pro1 IAQ Inc All rights reserved Mounting and Battery Installation For assistance with this product please visit http www pro1iaq com or call Pro1 Customer Care toll free at 888 Pro1iaq 776 1427 during normal business hours Mon Fri 9 AM 6 PM Eastern Rev 1043 ...

Page 2: ......

Page 3: ...ermostat becomes inoperable Getting to know your thermostat LCD 1 2 Fan Switch 3 System Switch 4 Easy Change Battery Door 5 Setpoint Buttons 1 2 3 4 5 Low Battery Indicator Replace batteries when indicator is shown 1 will appear in the display when the auxiliary heat is active Indicates the current room temperature Displays the user selectable setpoint temperature System operation indicators ON wi...

Page 4: ...SUBBASE INSTALLATION ...

Page 5: ......

Page 6: ......

Page 7: ... delay ON or OFF with the jumper pin Reset button Delay The compressor delay will not allow the compressor to be turned on for 5 minutes after the last time the compressor was on The cooling icon will flash during the delay period Select OFF or ON with the jumper pin as desired ...

Page 8: ...re swing sometimes called differetial or cycle rate can be customized for this individual application For most applications choose a swing setting that is as long as possible without making the occupants uncomfortable PRO1 Tip 1 2 3 4 1 2 3 4 Select HEAT or COOL with the system switch Hold down the and keys together for 3 seconds Use the or key to adjust the swing The swing is adjustable from 02 F...

Page 9: ...subbase 9 ...

Page 10: ...riday 9 AM 6 PM Eastern 41ºF to 95ºF 5ºC to 35ºC 44ºF to 90ºF 7ºC to 32ºC 1 amp per terminal 1 5 amp maximum all terminals combined 1ºF Heating is adjustable from 0 2ºF to 2 0ºF Cooling is adjustable from 0 2ºF to 2 0ºF 18 to 30 VAC NEC Class II 50 60 Hz for hardwire common wire Battery power from 2 AA Alkaline batteries 32º to 105º 0º to 41ºC 90 non condensing maximum 4 7 W x 4 4 H x 1 1 D ...

Reviews: