TECHNICIAN SETUP MENU

If 

ON

 is selected 

the beep will 

sound. If 

OFF 

is selected, 

there is no sound.

OFF

 configures 

display light to 

come on only with 

the light key, 

which will save 

battery power.

ON

 configures the 

display light to 

come on when any 

key is pressed.

OFF

 configures 

the thermostat 

for non heat 

pump systems

ON

 configures 

the thermostat 

for heat pump 

systems

ON

OFF

ON

OFF

Adjustment Options

Factory Default Settings

The display light 

can be configured 

to come on when 

any key is pressed 

or only when the 

light key is 

pressed. 

When any key 

is pressed an 

audible beep 

will sound. 

You can choose 

ON

 or 

OFF

When turned on 

the thermostat 

will operate a 

heat pump.

1.

 EM.Heat will 

show as an option 

in the system 

switch.

2.

 Y will be first 

stage of heat & 

cool, W/E  will be 

emergency heat 

relay & W2 will 

be auxiliary heat 

relay. 

Allows you to put 

your phone number 

in the display.

You can choose 

ON

 or 

OFF

Tech Setup Steps (Continued from the previous page)

Contractor 

Call Number

Beep

Heat Pump

Display

Light

LCD Will Show

Heat - Off - Cool

You can configure the 

system switch for the 

particular application: 

Heat - Off - Cool,

Heat - Off, 

Cool - Off, 

Heat - Off - Cool-Auto 

Note: EM. Heat 

will 

show if in heat pump 

mode.

System 

Switch

Gas Auxiliary

for Heat Pump

Stages

of Heat

Cooling Fan

Delay

Use the         or 

key until the desired 

application is 

flashing.

OFF

OFF

2 Stages

Use the         or 

key to select the 

desired number and 

the 

FAN 

or 

SYSTEM

 

key to move from 

one character to 

another. See note 

below on operation.

If selected on, you 

will see the input 

screen after pressing 

next step.

Note:

 If Contractor Call Number is selected 

ON, your phone number 

will show in the display if there has been a continuous call for heating 
or cooling for 24 hours or if the light button is held down for 3 seconds.
To remove the phone number from the display, hold the light button 
down for 3 seconds.   

You can configure the 

thermostat to operate 

a 3 stage heat pump 

system.

2H 2C = 2 heat, 2 cool

3H 2C = 3 heat, 2 cool 

The cooling fan delay 

setting will delay the 

fan from coming on in 

cool mode and keep 

running after the 

compressor shuts off 

for a short time to save 

energy in some 

systems. 

You can select the 

Cooling Fan Delay 

from "Off"  "15" "30" 

"60" or "90" seconds.  

If 15 30 60 or 90 is 

selected the fan will 

not turn on for that 

many seconds when 

there is a call for cool 

and will run for that 

many seconds after 

satisfying a call for 

cool.

Use the         or 

key to change between 

2 heat and 3 heat.

2 heat will use Y1 as 

first stage and W2 as 

auxiliary.

3 heat will use Y1 as 

first stage, Y2 as 

second stage and 

W2 as auxiliary.

This option will turn 

the heat pump off 45 

seconds after the 

auxiliary heat relay 

turns on.  

For 2 heat 

applications, the first 

stage will turn off 45 

seconds after the 

auxiliary stage turns 

on.  

For 3 heat 

applications, the first 

and second stage will 

turn off 45 seconds 

after the auxiliary 

stage turns on.

For heat pump 

systems that are 

“dual fuel” (use a 

gas furnace for 

auxiliary stage heat) 

you can turn this 

feature on to turn off 

the heat pump when 

the auxiliary stage of 

heating has been 

called for.

Summary of Contents for Toptech TT-S-855

Page 1: ...mmon Wire with Battery Backup Power Type 1 n o i t p i r c s e D Gas or Oil Heat Electric Furnace Heat Pump No Aux or Emergency Heat Heat Pump with Aux or Emergency Heat Multi stage Systems Heat Only Systems Heat Only Systems Cool Only Systems Millivolt Yes Yes Yes Yes Yes Yes Yes Yes Yes Rev 0950 Una versión española de este manual puede ser descargada en www pro1iaq com U S Registered Trademark ...

Page 2: ... are in direct sunlight With an outside wall behind the thermostat In areas that do not require conditioning Where there are dead spots or drafts in corners or behind doors Where there might be concealed chimneys or pipes Where appliances could radiate heat Pick an installation location that is easy for the user to access The temperature of the location should be representative of the building Wal...

Page 3: ...isplayed when thermostat program is permanently overridden 1 will appear in the display when second stage of heat or cool is on 2 will appear for third stage of heat System operation indicators The COOL HEAT or FAN icon will display when the COOL HEAT or FAN is on NOTE The compressor delay feature is active if these icons are flashing The compressor will not turn on until the 5 minute delay has el...

Page 4: ...oducts are mercury free However if the product you are replacing contains mercury dispose of it properly Your local waste management authority can give you instructions on recycling and proper disposal Horizontal mount Horizontal mount Vertical mount Vertical mount For vertical mount put one screw top and one screw bottom For horizontal mount put one screw left and one screw right C O B W E W2 R G...

Page 5: ...ergized in cooling Fan relay Emergency heat relay First stage of heat cool Second stage of cool second stage of heat Auxiliary heat relay third stage of heat This thermostat is shipped from the factory to operate a conventional heating and cooling system This thermostat will also operate a heat pump system See the heat pump configuration step on page 8 of this manual to configure the thermostat fo...

Page 6: ...s and a larger swing setting will cause fewer cycles Keypad lockout allows you to configure the thermostat so that none or some of the keys do not function The heating swing setting is adjustable from 0 4 F to 2 F For example A swing setting of 0 5 F will turn the heating on at approximately 0 5 F below the setpoint and turn the heating off at approximately 0 5 F above the setpoint Pick PA or FU P...

Page 7: ... or 24 Hour Clock Use the or key to turn on or off ON This feature turns your system on before the WAKE programming time to ensure the enviroment is at the WAKE setpoint when the WAKE time period begins This recovery changes over time based on the previous days experience Morning Recovery Use the or key to select 7d for 7 day 5d for 5 1 1 or 0d for nonprogammable 5d You can configure this thermost...

Page 8: ... one character to another See note below on operation If selected on you will see the input screen after pressing next step Note If Contractor Call Number is selected ON your phone number will show in the display if there has been a continuous call for heating or cooling for 24 hours or if the light button is held down for 3 seconds To remove the phone number from the display hold the light button...

Page 9: ...LLATION Mount Thermostat Align the 4 tabs on the subbase with corresponding slots on the back of the thermostat then push gently until the thermostat snaps in place On the back of the thermostat insert 2 AA Alkaline batteries included ...

Page 10: ...ing Use the or key to select the current day of the week Press NEXT STEP The current hour is flashing Use the or key to select the current hour When using 12 hour time make sure the correct a m or p m choice is selected Press NEXT STEP Minutes are now flashing Use the or key to select current minutes Press DONE when completed 1 2 3 4 5 6 7 8 All programmable Pro1 thermostats are shipped with an en...

Page 11: ...time period Note If you want the fan to run continuously during this time period select ON with the FAN key Press NEXT STEP The setpoint temperature is flashing Use the or key to make your setpoint selection for the weekday WAKE period Press NEXT STEP Repeat steps 4 through 7 for weekday LEAVE time period for weekday RETURN time period and for weekday SLEEP time period Repeat steps 4 through 7 for...

Page 12: ...STEP Repeat steps 4 thru 7 for Monday LEAVE time period for Monday RETURN time period and for Monday SLEEP time period PROGRAMMING THE THERMOSTAT 12 1 2 3 4 5 6 7 8 Monday Repeat steps 4 thru 7 for the remaining days of the week Tuesday Wednesday Thursday Friday Saturday Sunday A Note About Auto Changeover Auto changeover will switch between heating and cooling as needed It is very important to ma...

Page 13: ...s adjustable from 0 4ºF to 2 0ºF Cooling is adjustable from 0 4ºF to 2 0ºF 18 to 30 VAC NEC Class II 50 60 Hz for hardwire common wire Battery power from 2 AA Alkaline Energizer batteries 32ºF to 105ºF 0º to 41ºC 90 non condensing maximum 4 7 W x 4 4 H x 1 1 D 13 SPECIFICATIONS CONTACT INFORMATION Specifications Pro1 IAQ Inc 1111 S Glenstone Suite 2 100 Springfield MO 65804 Toll free 1 888 Pro1iaq...

Reviews: