Operating Instructions
Installation
20 / 34
V4
GB
4.6
Refueling the engine
•
Gasoline is highly flammable. Always keep the fuel tank closed.
•
Do not smoke or allow flames when using gasoline. Do not inhale the fumes.
•
To refuel the engine, switch off the device and engine.
•
Only refuel the engine when it is switched off and cooled down.
•
After refueling, tightly close the tank.
•
Do not fill the fuel tank completely; fill up to approx. 4cm under the brim of the fill neck, so the fuel has
room to expand.
•
Starting the engine
•
Stopping the engine
4.7
Use of the spreader bar with 2 (3) suction plates
When using the spreader bar/travers with 2 suction plates only suction plates of the same design (carrying capacity/WLL,
dimensions and form) may be used!
The suction plates must always have the
same
distance (A) to the vertical centre axis of the spreader bar/traverse (see
figure 1).
Unequal positioning of the suction plates is not permitted (see figure 2)!
Take care that the load (stone slab) hangs always
horizontal
.
For special spreader bars/traverses where 3 suction plates are permitted, they must be positioned in the same way (see
Fig. 3).
A
A
Figure 1
B
A
Figure 2
Spreader bar
Vacuum-
device
Suction plate