Operating Instructions
Operating
25 / 34
V4
GB
5.2.2
Releasing the load:
•
Lower the load to a safe and clear, level surface, to
ensure that the load cannot slip or tip over.
•
Shift the bushing on the slide valve (A) back. The load is
released.
5.2.3
Lifting wet loads
•
The lifting device is not intended for picking up wet stone slabs. When picking up wet stone slabs, please observe
the following:
•
Remove water from the suction surface.
•
Carry out the following points after working with damp parts:
•
Lift up the lifting device. Make sure that the area around the suction plate is clear and that no items or water can be
drawn in.
•
Let the pump idle to run dry for at least 5 minutes.
•
Then switch off the device.
•
Open the condensate drain screw on the bottom of the storage container. Drain the water completely and tighten
the drain screw securely.