Maintenance and care
29 / 34
V4
GB
7
Maintenance and care
7.1
Maintenance
To ensure the correct function, safety and service life of the device the following points must be executed in
the maintenance interval.
Used
only original spare parts
, otherwise the warranty expires.
All operations
may only be made in unpressurised, electro less and closed state of the device!
The device must be installed and maintained by qualified personnel such as mechanics and electricians only.
After each repair or maintenance job check the safety equipment as described in the "Safety" chapter.
MECHNICAL
SERVICE INTERVAL
Maintenance work
First inspection after
25 operating hours
•
Control and tighten all screws and connections.
(The implementation is only allowed by an expert).
After 50 operating hours
•
Tighten all screws and connections (take care that the tightening torques according
to the property class of the screws are observed).
•
Check all joints, bolts, guidance’s and gears for correct function, if necessary adjust or
replace it.
Minimum 1x per year
(at rough conditions shorten the
interval)
•
Check of all the suspension parts, bolts and straps. Check for corrosion and safety by
an expert.
7.1.1
Electrics
Service interval
Maintenance work
After 25 operating hours
•
Control all electrical connections and/or retighten (the implementation is only
allowed by an expert)
All 50 operating hours
•
Check all fuses (if existing)
•
Check the electric cabling for breaks and abrasion, if necessary replace it (only
qualified personal)