background image

MACHINE OPERATIONS 

 COMANCHE  86038890  03/20/07 

    3-4 

 
SHUT DOWN AND STORAGE 

1. 

Turn Switch OFF. Empty recovery tank 
completely and rinse several times to remove 
any dirt or debris that may be left behind.

 

2. 

Drain any unused cleaning solution from solution 
tank and rinse with clean water to remove any 
suds left behind by the cleaning chemicals. 

NOTE:

 

Dispose of waste in a proper manner 

which would not violate any Local, State or 
Federal law
 

3. 

Run a small amount of clean water through 
pump if chemicals were used. This will help 
insure the life of your pump.

 

4. 

Check the spray jet on the cleaning tool for full 
spray pattern and inspect vac head for any 
obstructions. 

 

5. 

Remove as much moisture from system before 
storing in cold climates. Excess water may 
freeze during storage and crack internal 
components, causing damage to the unit.

 

 

Summary of Contents for Comanche 10075270

Page 1: ...MODELS CM1 10075270 CM2 10075290 CM2H 10075310 Operating Instructions 86038890 06 09 09 PRV NO 98929 R PORTABLE EXTRACTOR Read these instructions before using the machine...

Page 2: ...___________________________________________________________ Phone Number _________________________________________________________________________________________ MODEL _______________________________...

Page 3: ...and Storage 3 4 MAINTENANCE Daily Maintenance 4 1 Periodic Maintenance 4 1 Monthly Maintenance 4 1 Semi annually 4 1 Lubrication 4 1 Storage 4 1 Solution Pump Replacement 4 2 Vacuum Motor Replacement...

Page 4: ...PARTS LIST section contains assembled parts illustrations and corresponding parts list The parts lists include a number of columns of information REF column refers to the reference number on the part...

Page 5: ...st or vapors This machine is suitable for commercial use for example in hotels schools hospitals factories shops and offices for more than normal housekeeping purposes Maintenance and repairs must be...

Page 6: ...afe operation of equipment Report machine damage or faulty operation immediately Do not use the machine if it is not in proper operating condition Following is information that signals some potentiall...

Page 7: ...let that is properly installed and grounded in accordance with all local codes and ordinances This appliance is for use on a nominal 120 volt circuit and has a grounded plug that looks like the plug i...

Page 8: ...Electrical 115V 60HZ Electric Vacuum Motor DUAL 2 STAGE Solution Pump 100PSI Solution Capacity 10 gal 38L Recovery Capacity 10 gal 38L Dimensions Weight Empty 81 lbs 37kgs Dimensions Length 31 in 78 7...

Page 9: ...86038890 03 20 07 3 2 Vacuum Inlet Solution Outlet Solution Tank Vacuum 2 Vacuum 1 Vacuum Tank Water Pump Heater Optional Accessory 10073510 PRV NO CM2H standard option Base Assembly Dump Valve Soluti...

Page 10: ...NING EMPTYING TANKS Always use defoamer if foaming occurs Foam will suspend large particles which may damage vacuum as well as allow liquid into the vacuum motor without activating the float shutoff 1...

Page 11: ...by the cleaning chemicals NOTE Dispose of waste in a proper manner which would not violate any Local State or Federal law 3 Run a small amount of clean water through pump if chemicals were used This w...

Page 12: ...s covers removed to allow tanks to dry PERIODIC MAINTENANCE 1 Twice a month flush a white vinegar solution one quart vinegar to two gallons water or anti browning solution mixed as directed through th...

Page 13: ...tor is grooved extremely pitted or not concentric the motor will need to be replaced or sent to a qualified service center Important These brushes wear quicker as the length shortens due to increased...

Page 14: ...with Superlube 6 Reassemble regulator 7 With pump ON re adjust pressure regulator for normal operation LUBRICATE U CUP WITH SUPERLUBE MONTHLY P IS T O N S P R IN G R E T A IN E R P L A T E S P R IN G...

Page 15: ...open valve on cleaning wand to relieve air Pump runs no solution Internal or external solution line damaged and leaking Replace Internal pump components wearing out Replace see pump kit components Pg...