DAILY MAINTENANCE

 

 

 

1.  Flush the entire system, including floor tool, 

hand tool, etc., with 1 to 3 gallons of clean, hot 
water. 

2.  Vacuum out the solution tank. 
3.  Rinse tank with fresh water. Periodically inspect 

the recovery tank and decontaminate if 
necessary, using a Hospital Grade Virucide or a 
1-10 bleach to water solution. Wastewater 
should be disposed of properly. 

4.  Occasionally check filter screen at the bottom of 

the solution tank and rinse clean with hot water if 
necessary. 

5.  Inspect hoses for wear.  Frayed or cracked 

hoses should be replaced to avoid vacuum or 
solution pressure loss. 

6.  Inspect power cord for wear or damage.  This 

cable will lie on wet carpet.  To prevent electrical 
shock replace cords that are frayed or have 
cracked insulation immediately. 

7.  Clean all dirt and obstructions from drain valve 

and gaskets to prevent possible leakage and 
premature wear. 

8.  Run clean water through solution pump when 

work is complete. 

9.  Empty both tanks and rinse, run vacuum (s) for 

at least one minute to dry motor(s). 

10.  Store with access covers removed to allow tanks 

to dry. 

 
PERIODIC MAINTENANCE

 

1. 

Twice a month, flush a white vinegar solution 
(one quart vinegar to two gallons water) or anti-
browning solution (mixed as directed) through 
the extractor. This will prevent build-up of 
alkaline residue in the system.

 

2. 

If spray jet becomes clogged, remove the spray 
tip, wash it thoroughly, and blow dry. 

NOTE

D

NOT USE PINS

WIRE

ETC

TO CLEAN NOZZLE AS 

THIS COULD DESTROY THE SPRAY PATTERN

3. 

Apply silicone lubricant to solution nipple.

 

4. 

Periodically inspect all hoses, electrical cable 
and connections on your machine. Frayed or 
cracked hoses should be repaired or replaced to 
eliminate vacuum or solution pressure loss. If 
the cable insulation on the power cord is broken 
or frayed, repair or replace immediately. Don’t 
take chances with electrical fire or shock.

 

5. 

Clean outside of all tanks and check for 
damage.

 

 

MONTHLY MAINTENANCE 

 

1.  Check all bearings for noise and wear. 
2.  Check all gaskets for wear and leakage. 
3.  Check pump pressure; observe spray pattern 

and check gauge if necessary. 

4.  Check overall performance of machine. 

 
SEMI-ANNUALLY 
 

1.  Check vacuum motor brushes

 

LUBRICATION 

 

For hose fitting lubrication, use a light silicone 
lubricant which will not damage o-rings. 

 

STORAGE 

 

Thoroughly clean machine if it is to be stored. 
Protect this machine from freezing while in storage. 

 

Summary of Contents for Comanche 10075270

Page 1: ...MODELS CM1 10075270 CM2 10075290 CM2H 10075310 Operating Instructions 86038890 06 09 09 PRV NO 98929 R PORTABLE EXTRACTOR Read these instructions before using the machine...

Page 2: ...___________________________________________________________ Phone Number _________________________________________________________________________________________ MODEL _______________________________...

Page 3: ...and Storage 3 4 MAINTENANCE Daily Maintenance 4 1 Periodic Maintenance 4 1 Monthly Maintenance 4 1 Semi annually 4 1 Lubrication 4 1 Storage 4 1 Solution Pump Replacement 4 2 Vacuum Motor Replacement...

Page 4: ...PARTS LIST section contains assembled parts illustrations and corresponding parts list The parts lists include a number of columns of information REF column refers to the reference number on the part...

Page 5: ...st or vapors This machine is suitable for commercial use for example in hotels schools hospitals factories shops and offices for more than normal housekeeping purposes Maintenance and repairs must be...

Page 6: ...afe operation of equipment Report machine damage or faulty operation immediately Do not use the machine if it is not in proper operating condition Following is information that signals some potentiall...

Page 7: ...let that is properly installed and grounded in accordance with all local codes and ordinances This appliance is for use on a nominal 120 volt circuit and has a grounded plug that looks like the plug i...

Page 8: ...Electrical 115V 60HZ Electric Vacuum Motor DUAL 2 STAGE Solution Pump 100PSI Solution Capacity 10 gal 38L Recovery Capacity 10 gal 38L Dimensions Weight Empty 81 lbs 37kgs Dimensions Length 31 in 78 7...

Page 9: ...86038890 03 20 07 3 2 Vacuum Inlet Solution Outlet Solution Tank Vacuum 2 Vacuum 1 Vacuum Tank Water Pump Heater Optional Accessory 10073510 PRV NO CM2H standard option Base Assembly Dump Valve Soluti...

Page 10: ...NING EMPTYING TANKS Always use defoamer if foaming occurs Foam will suspend large particles which may damage vacuum as well as allow liquid into the vacuum motor without activating the float shutoff 1...

Page 11: ...by the cleaning chemicals NOTE Dispose of waste in a proper manner which would not violate any Local State or Federal law 3 Run a small amount of clean water through pump if chemicals were used This w...

Page 12: ...s covers removed to allow tanks to dry PERIODIC MAINTENANCE 1 Twice a month flush a white vinegar solution one quart vinegar to two gallons water or anti browning solution mixed as directed through th...

Page 13: ...tor is grooved extremely pitted or not concentric the motor will need to be replaced or sent to a qualified service center Important These brushes wear quicker as the length shortens due to increased...

Page 14: ...with Superlube 6 Reassemble regulator 7 With pump ON re adjust pressure regulator for normal operation LUBRICATE U CUP WITH SUPERLUBE MONTHLY P IS T O N S P R IN G R E T A IN E R P L A T E S P R IN G...

Page 15: ...open valve on cleaning wand to relieve air Pump runs no solution Internal or external solution line damaged and leaking Replace Internal pump components wearing out Replace see pump kit components Pg...