COMPONENTS
EVEREST 980086 02/18/03
3-6
14. SOLUTION TEMPERATURE CONTROL
VALVE
This valve enables additional heat exchangers
to contribute more heat to the system if
necessary. By rotating the lever to the right it
adds more heat, by rotating to the left it removes
heat.
15. OIL CUP
The oil cup allows lubricant spray to reach the
vacuum blower.
16. VACUUM INLETS
The vacuum inlets serve as connecting point for
vacuum hoses.
17. SOLUTION OUTLETS
The solution outlets are the connecting point for
the high pressure cleaning hoses. These
outlets are quick disconnects that allow hoses to
be plugged into the unit.
18. SOLUTION SCREEN
The solution screen is located on the front of the
machine. The function of this screen is to trap
foreign particles from exiting the machine and
plugging the orifices of the cleaning tools. This
screen is part of the machine maintenance
cleaning.
19. CHEMICAL CHECK VALVE
The chemical check valve allows chemicals to
enter the system and travel in a singular
direction to the wand. The chemical check
valve prevents chemicals from traveling up-
stream into the solution system of the unit.
20. HIGH PRESSURE SOLUTION OUTLET
The control valve sets the pressure of the
solution system. This spring loaded valve can
be adjusted up or down setting the pressure of
the unit by turning the valve clockwise. The
pressure is increased or reduced by turning the
valve counter clockwise.
21. HIGH PRESSURE REGULATOR
The regulating valve controls the amount of
pressure in the pressure washing circuit by
turning the handle clockwise, It has the effect of
increasing the pressure. Turning it clockwise
has the effect of lowering the pressure.
22. WASTE OUTLET
This valve allows the waste tank to be emptied.
Turning clockwise opens the valve.
NOTE: This valve must be open during
operation.
23. WASTE PUMPOUT
This auxiliary pump serves to empty the waste
collection tank automatically. A float located
inside the tank automatically turns off and on
when the solution level reaches certain points.
24. WARM WATER OUTLET
The warm water outlet allows the cleaning
technician to drain hot water from the water box
for mixing chemical.
Water from this valve is hot.
25. WATER INLET
This quick connect allows the water supply hose
to be connected to the unit.
26. SOLUTION PRESSURE
This selector valve allows the technician to
switch from high pressure to low pressure by
moving the handle to the up position. The high
pressure circuit is activated allowing the unit to
be used as a pressure washer by positioning
the valve handle to the down position. The low
pressure circuit is activated allowing the unit to
be used for carpet cleaning.
Summary of Contents for EVEREST HP
Page 28: ...NOTES EVEREST 980086 02 18 03 3 19 THIS PAGE LEFT BLANK INTENTIONALLY...
Page 53: ...CHEMICAL CONTROL PANEL EVEREST 980086 02 18 03 5 9 11 1 2 4 5 6 7 8 9 10 1 2 3 7 7 12 13 14...
Page 59: ...ENGINE EVEREST 980086 02 18 03 5 15 7 5 6 7 8 4 3 1 2 9 12 5 6 7 SUPPLIED WITH ENGINE 13...
Page 63: ...ENGINE GOVERNOR EVEREST 980086 02 18 03 5 19 4 5 3 2 1 9 6 4 5 7 10 11 12 11 13 14 15 16...
Page 77: ...SOLUTION TEMPERATURE CONTROL VALVE EVEREST 980086 12 16 03 5 33 2 3 4 6 5 7 4 1...
Page 95: ...BATTERY FLOOR MOUNT EVEREST 980086 06 07 03 5 51 3 1 2 4 8 6 5 7 10 2 2 9...