4.1 Monitor
The
Monitor
is an optimal aid for checking the system functions and logical program sequences. All
telegram traffic between CPU1, the modules and the peripherals is displayed here. The telegram traffic
can be stored.
Real time protocol
activates / deactivates telegram recording.
Stop display
stops the updating of the display position
Clear display
clears the content of the display
Marking off
resets all marking of entries that have been marked by selecting this checkbox in the
left-hand column.
(In the case of the checkbox being selected, the lines are displayed in color.)
Save display
stores the display in a file.
Redirect file
For recording over an extended period of time. Data are written directly to a file.
Note!
The number of entries in the list and per file can be specified under
ICS Settings
For performance
reasons, an excessively high value should not be selected for the list! The data of a recording are
additionally stored in a temporary file (ICS\temp\montemp.icsm).