User Guide
DVS-21
02/2018
• V.1.0 • L. Wolle
30/131
© 2017 ProCom
®
Professional Communication & Service GmbH • Technical changes reserved.
6.3 Module rack
Overview of all modules in a system. A new module is created or an existing one is configured here.
Modules that are used by existing programs are shown in gray. Modules without any
function/programming are shaded.
The first two positions are occupied by the
SV01
system power supply and the
CPU1
processor. If a
redundant standby CPU is provided, then positions 1-4 are occupied (2xSV01, 2xCPU1).
Select module rack
The type of
Module rack
that is in use can be selected on the right next to the module area.
Type
Wiring
corresponds to the familiar usage and is suitable for older systems as well as special
configurations.
It is essential to note that the item number may differ from the address in this type!
The address must be specified separately.
Type
BPxxx
must correspond to the rack in use in each case. The item numbers correspond to the
address.
The type can only be changed if no module is assigned!