User Guide
DVS-21
02/2018
• V.1.0 • L. Wolle
81/131
© 2017 ProCom
®
Professional Communication & Service GmbH • Technical changes reserved.
Destination call station
To enter address
The address of the destination is specified directly and not determined via the
Call
station number
.
Call station number
Unique number of the
Destination call station
Special line
The line is switched on if the program is activated. For example, relays can be
switched or keys can be illuminated.
Flag (NAND)
[IN] The program can be turned off by this flag or switching on can be prevented.
Flag (OR)
[IN] The program can be switched on by this flag. It is possible to acquire AF
channels.
Flag (OUT) 1/2
[OUT] The flag is switched on if the program is activated. Further programs can be
activated thereby if adaptation to individual requirements is required.
Busy flag
[OUT] for processing the busy state
Clear flag
[IN] The connection can be broken by means of this flag.
9.6 IC Group
The
IC Group
program established a connection with multiple call stations simultaneously. Calls take
place without further configuration as a "conference" (each to each)
Priority
Handling of priorities (
Codec
Audio compression method by which the codec handles the actual connection.
The options are: µLaw (default), ADPCM (7kHz) and aLaw (
Interval time
By specifying a time <> 0, a group call switches, once a subscriber has
answered, to a selective IC call between the two subscribers. The call remains
selective, as long as someone speaks within the time.
No receiving in idle
state
The call station does not receive any calls of the group. It can, however,
establish a connection to the group. Having said this, by using the
programmed
Interval time
a selective call can be made by a subscriber replying.
Own/Analog
Selects the type of call station (ProCom or analog call stations).
Input/call station
(Setting
Own
)
Address, Port, Line
Address and port of the module to which the station is connected and the line
(key) that is used. (
Input/call station
(Setting
Analog
)
Address AF, Port
Address and port of the module to which the AF line of the call station is
connected. (
Address 24LI, Port, Line
Address and port of the module to which the control line of the call station is
connected. (
Call storage
Time for which the key is illuminated (flashing) after missed calls