background image

  1 0

2.   Open  gas supply tank valve.
3.   Make sure control knob of heater is

in the OFF  position.

4.  Check all joints from equipment

shutoff valve to control valve
(LP  GAS  see  Figure  9.1  NATURAL
GAS  see  Figure  9.2).   Apply
mixture of liquid soap and  water
to  gas  joints.  Bubbles forming
show  a  leak.

5.   Correct all leaks at once.
6.  Light heater (see  Operating

Heater). Check all other internal
joints  for  leaks.

7.  Turn  off  heater (see To Turn Off
      Gas  Appliance).

       

  WARNING:

   Failure  to  position

the  parts  in  accordance  with  these
diagrams  or  failure  to  use  only  parts
specifically  approved  with  this  heater
may  result  in  property  damage  or
personal  injury.

       

  CAUTION:

    After  installation

and  periodically  thereafter,  check  to
ensure  that  no  flame  comes  in
contact   with  any  log.  With  the  heater
set  to  High, check  to  see  if  flames
contact  any  log. If  so, reposition  logs
according  to the log  installation
instructions  in  this  manual. Flames
contacting  logs  will  create  soot.

It is very important to install the logs
exactly as instructed. Do not modify
logs. Only use logs supplied with
heater.

Place  log  set  on  grate  to fit  as
illustrated  in  Figure  10.
Make  sure  log  sits  flat  on  firebox
floor (see Figure 10).

IMPORTANT

: Make  sure  log  does

not cover any burner ports (see Fig-
ure 11).

Also,  see  log  placing  instructions.

Figure  10 -Installing    Log  Set

Figure  11 -Installing  Log  Set (Top  View)

Figure  9.2 -Checking Gas Joints

Test  Pressures  Equal  To  or
Less  Than  1/2  PSIG(3.5 kPa

)

1.   Close  equipment  shutoff  valve

(see Figure  8).

2.   Pressurize  supply  piping  system

by  either  using  compressed  air  or
opening  natural  supply  tank
valve.

3.   Check  all  joints  from  gas  meter  to

equipment  shutoff  valve(see
Figure  9). Apply  mixture  of  liquid
soap  and  water  to  gas  joints.
Bubbles  forming  show  a  leak.

4.   Correct  all  leaks  at  once.

Summary of Contents for QL300RYLA

Page 1: ...of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer servi...

Page 2: ...n warnings 3 Air for conbustion Ventilation 5 Installation 7 Operation Heater 11 Cleaning and Maintenance 13 Specification 15 Troubleshooting 16 Parts Breakdown Parts List 18 Log Placing Instructions 22 Table of Contents ...

Page 3: ...u must operate this heater with the heater screen in place Make sure the heater screen is in place before running heater Keep the appliance area clear and free from combustible materials gasoline and other flammable vapors and liquids 1 This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases 2 Do not place Propane...

Page 4: ...s damaged promptly inform dealer where you bought stove PRODUCT FEATURES SAFETY PILOT This heater has a pilot with an Oxygen Depletion Sensing ODS safety shutoff system The ODS pilot is a required feature for vent free room heaters The ODS pilot shuts off the heater if there is not enough fresh air PRODUCT IDENTIFICATION Figure1 Vent Free LP NG Gas Stove Remote control SYSTEM This fireplace has a ...

Page 5: ...R LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space Space Includes the room in which you will install heater plus any adjoining rooms with doorless passageways or ventilation grills between the rooms 1 Determine the volume of the space length width height Length Width Height cu ft volume of space Example Space...

Page 6: ...nfined Figure 2 Ventilation Air from Inside Building Example Gas water heater 30 000 Btu Hr Vent free heater 26 000 Btu Hr Total 56 000 Btu Hr WARNING If the area in which the heater may be operated is smaller than that defined as an unconfined space or if the building is of unusually tight construction provide adequate combustion and ventilation air by one of the methods described in the National...

Page 7: ...Follow all local codes WARNING Never install the heater in a bedroom or bathroom in a recreational vehicle where curtains furniture clothing or other flammable objects are less than 42 inches from the front top or sides of the heater in high traffic areas in windy or drafty areas WARNING Maintain the minimum clearances If you can provide greater clearances from floor ceiling and adjoining side and...

Page 8: ...re installing heater make sure you have the items listed below piping check local codes sealant resistant to propane LP gas equipment shutoff valve test gauge connection sediment trap tee joint pipe wrench flexible gas hose check local codes A CSA design certified equipment shutoff valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purchase the optional CSA design certifi...

Page 9: ...s not installed or is installed incorrectly heater may not run properly CAUTION Avoid damage to regulator Hold gas regulator with wrench when connecting into gas piping and or fittings WARNING Never use an open flame to check for a leak Apply a mixture of liquid soap and water to all joints Bubbles forming show a leak Correct all leaks at once CAUTION Make sure external regulator has been installe...

Page 10: ...ck to see if flames contact any log If so reposition logs according to the log installation instructions in this manual Flames contacting logs will create soot It is very important to install the logs exactly as instructed Do not modify logs Only use logs supplied with heater Place log set on grate to fit as illustrated in Figure 10 Make sure log sits flat on firebox floor see Figure 10 IMPORTANT ...

Page 11: ...PERATING INSTRUTIONOF REMOTE CONTROLLEDBUNER LIGHTING INSTRUCTIONS 1 STOP Read the safety information page 2 2 Make sure equipment shutoff valve is fully open Figure 12 1 Emergency Button location C Use only your hand to push in control knob Never use tools If the the appli ance could not operate don t try to repair it Call a qualified service technician or gas supplier Forced or at tempted re pai...

Page 12: ... step 2 Point directly the remote transmitter to the burner Press IGN OFF button the electric spark starts igniting the pilot and operation light green on the front will be lit Wait five 5 minutes to clear out any air If you smell gas STOP Please check the gas connection There are three selections AUTO MAN and OFF a auto select of main burner Press BURNER button the flame is on AUTO select Press ø...

Page 13: ...are three selections AUTO MAN and OFF When pushing the FAN button on the AUTO select the fan will be controlled by the thermostat on the fan blower unit On the MAN select the fan will be kept in operation To stop the operation push the FAN button to OFF select See Fig17 CAUTION You must keep c o n t r o l a r e a s b u r n e r a n d circulating air passageways of heater clean Inspect these areas o...

Page 14: ...cuum cleaner nozzle 5 Blow air into the primary air holes on the injector holder 6 In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4 Clean the pilot assembly also A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly see ...

Page 15: ... of input adjustment FLEXILBE HOSE Flexibe gas hose is used for connect ing the heater to gas supply the flex hose must approved by CSA from your local dealer or Parts Central This part is not currently available from PRO COM EQUIPMENT SHUTOFFVALVE Equipment shutoff valve with 1 8 NPT tap Purchase date Usually we will ask you to return the defective part to the factory Warranty card PARTS NOT UNDE...

Page 16: ...n transmitter or battery isn t correctly assembly 1 Check the electric power 2 Place or replace the battery 1 Thermocouple connection loose at control board 2 Pilot flame not touching thermcouple which allows thermo couple to cool causing pilot flame to go out This problem could be caused by one or both of the following A Low gas pressure B Dirty or partially clogged ODS pilot 3 Thermocouple damag...

Page 17: ...gulator defective 1 Problem will stop after a few hours of operation 2 Check burner for dirt and debris If found clean burner see Cleaning and Maintenance page 13 3 Replace gas regulator Dark residue on logs or inside of fireplace 1 Improper log placement 2 Air holes at burner inlet blocked 3 Burner flame holes blocked 1 Properly locate logs see installing logs page 26 2 Clean out air holes at bur...

Page 18: ...1 8 ILLUSTRATED PARTS BREAKDOWN QL300RYLA QN300RYLA QL300RYLA W QN300RYLA W ...

Page 19: ...1 9 PARTS LIST QL300RYLA QN300RYLA QL300RYLA W QN300RYLA W ...

Page 20: ...2 0 ILLUSTRATED PARTS BREAKDOWN QL300RYLA QN300RYLA QL300RYLA W QN300RYLA W ...

Page 21: ...2 1 PARTS LIST QL300RYLA QN300RYLA QL300RYLA W QN300RYLA W ...

Page 22: ...s to put log sets in place to the gas stove indoor vent free NOTICE THE CORRECT POSITION OF THE LOGS SHOULD NOT IM PINGE ON THE FLAME THE LOG S PACKAGE IS LOCATED INSIDE THE UNIT THEN REMOVE SCREEN AND TAKE OUT THE LOG S PACKAGE FIRST REMOVE TWO TOP SCREWS FROM SCREEN BOTTOM PANEL ...

Page 23: ...2 3 Q SERIES LOG SET INSTALLATION INSTRUCTIONS ...

Page 24: ...he log 2 on the right rear angle iron see FIG 3 STEP 3 Install the log 3 on the front angle iron See FIG 4 1 INSTALLATION INSTRUCTIONS FOR LOG SETS 1 All logs FIG 1 FIG 2 STEP 1 Install the log 1 on the left rear angle iron see FIG 2 ...

Page 25: ...in on the left side of log 1 Place the lower part of log 4 on the flat roof at the left side of log 3 See FIG 5 STEP 4 Insert the pinhole on the upper part of log 5 into the pin on the log 2 Place the lower part of log 5 on the flat roof at the left side of log 3 See FIG 6 FIG 6 ...

Reviews: