6
We provide the manual control system in the event of power shortage.
Install battery for Manual Ignitor:
1. Unscrew the ignitor cap.
2. Insert a AAA type battery with its anode (“+”) pointing out.
3. Screw the ignitor cap back.
NOTE
:
We recommend that the battery be taken out of the ignitor when the power supply resumes.
LIGHTING INSTRUCTIONS
If power is off, you can operate the fireplace manually.
1. STOP! Read the safety information on page 14.
2. Check that gas supply to heater is on.
3. Open bottom front access panel.
4. Push in gas Control Knob slightly and turn clockwise to the OFF position. If Control Knob is on ELECTRIC
position, press in the Control Knob and turn counterclockwise to OFF position.
NOTE
:
Knob cannot be turned from PILOT/IGN to “OFF” unless knob is pushed in slightly. Do not force.
5. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas,
STOP!
Follow “B” in the safety information on page 14. If you do not smell gas, go to the next step.
6. Push in gas control slightly and turn counterclockwise
to PILOT/IGN and depress for five (5) seconds.
NOTE
:
The first time that the heater is operated after connecting the gas supply, the control knob should be
depressed for about thirty (30) seconds. This will allow air to bleed from the gas system.
LOCKING REMOTE CONTROL (CHILD PROOF)
1.
Key-press locking:
Press + button, a symbol will appear on the LCD.
2.
Key-press unlocking:
Press + button, the symbol will disappear on the LCD.
OPERATING FAN
Press button for desired fan operation.
ON:
Blower will come on several minutes after burner comes on.
OFF:
Blower is off.
MANUAL OPERATING INSTRUCTIONS
Figure 23 - Manual Control
TO TURN OFF GAS TO APPLIANCE
Shut off heater
1. Press the button.
2. Set Switch on OFF position or unplug the electric power to the heater. (See Figure 20)
SETTING TIMER
Auto Off:
With burner operating, press button. Then press or to change to the scheduled time. Press the
button again; the starts timing. Burner will automatically shut off a set time.
SETTING TEMPERATURE
With burner is operation, press button, then press or to change to the desired temperature.
Burner will attomatically shut off when the room temperature is higher than setting temperatrue and burner will auto-
matically turn on when the room temperature is lower the setting temperature.
The show of the battery in low discharge :
When the battery in low discharge , the LCD will be . If you change the new battery , the
will be disappearing in the LCD.