Summary of Contents for MATRIX88

Page 1: ...INDEX ...

Page 2: ...1 IMPORTANT SAFETY INSTRUCTIONS 8 DESCRIPTION Main functions ...

Page 3: ...9 FRONT PANEL fig 1 1 SOURCE UP SOURCE DOWN 2 SOURCE CHANNEL DISPLAY 3 PAGE BUSY 4 Led MIC1 PRIORITY 5 MIC1 PRIORITY 6 MIC1 7 MUSIC LEVEL 8 MASTER ...

Page 4: ...9 ZONE DISPLAY 10 ZONE SELECT 11 ENTER 12 OUTPUT LEVEL 13 ESC 14 Volume MONITOR 15 BGM ALL Note If the power supply should fail the BGM setting will be kept 16 PAGE ALL 17 ON OFF Switch ...

Page 5: ...with built in fuse Note if connecting with a 117 V AC 50 60 Hz mains remember to move the mains selector to the117 V AC position fig 2 ref 2 2 Mains Selector 230 117 V AC 50 60 Hz 3 ESTENSION LINK fig 3 Note to set any Dip Switch see point 5 in chapter 4 ...

Page 6: ...e adjustments on the zone output D PAGE E ZONE REMOTE CONTROL Input Note Each remote control operates within the audio zone to which it is connected e g if it is connected to ZONE REMOTE CONTROL 4 it will operate only within zone 4 Piedino N Assegnazione ...

Page 7: ...local source be it microphone or line directly connected to the remote control 5 DIP SWITCH Note If you have a system with several MATRIX88s the 8 audio source inputs the MIC1 input and the 2 paging console inputs on the SLAVE units will not be active All the SLAVE units connected to the MASTER unit will use the above mentioned inputs on the MASTER MATRIX unit The inputs for R88 R88L and LOC02 rem...

Page 8: ...d 4 all other zones will keep on working normally Reproduction of the ALERT siren Reproduction of the EVAC siren Reproduction of the BASE siren Note Each contact acts only on its own MATRIX88 If you have an extended system consisting of several daisy chained MATRIX88s contacts can be independently set ...

Page 9: ...recorded evacuation or alert message from a message generator Proel DIGI8 interfaced with the fire alarm control panel If you have an extended system featuring several daisy chained MATRIX88 units parallel connect the message generator to all the EMC IN inputs so that the same message be heard in all the zones 8 LINE1 LINE4 Note This is a mono system therefore any stereo input will be summed to mo...

Page 10: ...e cannot be used If the system includes several daisy chained MATRIX88 units you can only connect 2 BM8X8 paging consoles to the PAGING MIC inputs on the Master unit Those consoles will operate on the whole system 13 GAIN PAGING MIC1 MIC2 14 MICROPHONE 1 input 15 MlC1 Gain 16 MIC1 Input Tone Control Piedino N Assegnazione ...

Page 11: ...11 CONNECTION DIAGRAM FOR AN 8 ZONE SYSTEM fig 5 ...

Page 12: ...12 CONNECTION DIAGRAM FOR A SYSTEM OF UP TO 32 ZONES fig 6 ...

Page 13: ...Detail of four daisy chained MATRIX88 units 13 TIPI DI CONNESSIONE ...

Page 14: ... Impedance Local Input Sensitivity Local Gain MIC1 Impedance Zone Output Zone Output Level Control S N Ratio Channel Crosstalk Distortion T H D Rs485 Communication Protocol Power supply Dimensions W x H x D Weight EN 50082 1 1997 EN 55013 1990 EN 55020 1994 EN 60065 1998 ...

Page 15: ......

Page 16: ......

Page 17: ...www proel com ...