background image

10

ENGLISH LANGUAGE
SAFETY AND PRECAUTIONS

• 

 

CAUTION:

 before using this product read carefully the following safety instruc  ons. Take a look of this manual en  rely and preserve it for 

future reference.
  When using any electric product, basic precau  ons should always be taken, including the following:
–  To reduce the risk, close supervision is necessary when the product is used near children.
–  Protect the apparatus from atmospheric agents and keep it away from water, rain and high humidity places.
–  This product should be site away from heat sources such as radiators, lamps and any other device that generate heat. 
–  Care should be taken so that objects and liquids do not go inside the product.
–  The product should be connected to a power supply mains line only of the type described on the opera  ng instruc  ons or as marked on the 
product. Connect the apparatus to a power supply using only power cord included making always sure it is in good condi  ons.
– 

 

WARNING:

 The mains plug is used as disconnect device, the disconnect device shall remain readily operable.

–  Power supply cord should be unplugged from the outlet during strong thunderstorm or when le   unused for a long period of   me.
–  Do not place objects on the product’s power cord or place it in a posi  on where anyone could trip over, walk on or roll anything over it. Do not 
allow the product to rest on or to be installed over power cords of any type. Improper installa  ons of this type create the possibility of 

fi

 re hazard 

and/or personal injury.

IN CASE OF FAULT

•  In case of fault or maintenance this product should be inspected only by quali

fi

 ed service personnel when:

–  There is a 

fl

 aw either in the connec  ons or in the supplied connec  ng cables.

–  Liquids have spilled inside the product.
–  The product has fallen and been damaged.
–  The product does not appear to operate normally or exhibits a marked change in performance.
–  The product has been lost liquids or gases or the enclosure is damaged.
•  Do not operate on the product, it has no user-serviceable parts inside, refer servicing to an authorized maintenance centre.

CE CONFORMITY

•  Proel products comply with direc  ve 2004/108/EC (EMC), as stated in EN 55013 standard and with direc  ve 2006/95/CE (LVD), as stated in EN 
60065 standard.
•  Under the EM disturbance, the ra  o of signal-noise will be changed above 10dB.

PACKAGING, SHIPPING AND COMPLAINT

•  This unit package has been submi  ed to ISTA 1A integrity tests. We suggest you control the unit condi  ons immediately a  er unpacking it.
•  If any damage is found, immediately advise the dealer. Keep all unit packaging parts to allow inspec  on.
•  Proel is not responsible for any damage that occurs during shipment.
•  Products are sold “delivered ex warehouse” and shipment is at charge and risk of the buyer.
•  Possible damages to unit should be immediately no  

fi

 ed to forwarder. Each complaint for package tampered with should be done within eight 

days from product receipt.

WARRANTY AND PRODUCTS RETURN

•  Proel products have opera  ng warranty and comply their speci

fi

 ca  ons, as stated by manufacturer.

•  Proel warrants all materials, workmanship and proper opera  on of this product for a period of two years from the original date of purchase. If 
any defects are found in the materials or workmanship or if the product fails to func  on properly during the applicable warranty period, the owner 
should inform about these defects the dealer or the distributor, providing receipt or invoice of date of purchase and defect detailed descrip  on. 
This warranty does not extend to damage resul  ng from improper installa  on, misuse, neglect or abuse. Proel S.p.A. will verify damage on returned 
units, and when the unit has been properly used and warranty is s  ll valid, then the unit will be replaced or repaired. Proel S.p.A. is not responsible 
for any "direct damage" or "indirect damage" caused by product defec  veness.

INSTALLATION AND DISCLAIMER

•  Proel products have been expressly designed for audio applica  on, with signals in audio range (20Hz to 20kHz). Proel has no liability for damages 
caused in case of lack of maintenance, modi

fi

 ca  ons, improper use or improper installa  on non-applying safety instruc  ons.

•  Proel S.p.A. reserves the right to change these speci

fi

 ca  ons at any   me without no  ce.

•  Proel S.p.A. declines any liability for damages to objects or persons caused by lacks of maintenance, improper use, installa  on not performed 
with safety precau  ons and at the state of the art.

POWER SUPPLY AND MAINTENANCE

•  Clean only with dry cloth.
• Before connec  ng the product to the mains outlet make certain that the mains line voltage matches that shown on the rear of the product, a 
tolerance of up to ±10% is acceptable.

Summary of Contents for MI16

Page 1: ...Mi16 16 CH 2 BUS MIXER WITH FX USER MANUAL MANUALE D USO ...

Page 2: ...may be of sufficient magnitude to cons tute a risk of electric shock to persons The exclama on point within an equilateral triangle is intended to alert the user to the presence of important opera ng and maintenance servicing instruc ons in the literature accompanying the appliance The informa on contained in this publica on has been carefully prepared and checked However no responsibility will be t...

Page 3: ...10 POWER SUPPLY AND MAINTENANCE 10 GENERAL INFORMATION 11 OPERATING INSTRUCTIONS FIG 1 2 3 4 11 INDICE SPECIFICHE TECNICHE 4 DIMENSIONI MECCANICHE 5 LAY OUT 6 PANNELLO DI CONTROLLO FIG 2 7 PANNELLO POSTERIORE FIG 3 8 CONNESSIONI FIG 4 8 ESEMPIO CONFIGURAZIONE 9 LINGUA ITALIANA 16 AVVERTENZE PER LA SICUREZZA 16 IN CASO DI GUASTO 16 CONFORMITÀ CE 16 IMBALLAGGIO TRASPORTO E RECLAMI 16 GARANZIE E RESI...

Page 4: ... AUX 0 dBu Jack Sbilanciato 2 TRK nom out level 0 dBu Unbalanced Rca Livello nom 2 TRK OUT 0 dBu Rca Sbilanciato 2 TRK nom in level 0 dBu Unbalanced Rca Livello nom 2 TRK IN 0 dBu Rca Sbilanciato PHONES min impedance 32 ohm Stereo Jack Impedenza min PHONES 32 ohm Jack Stereo PHONES max out level 2x 193 mW Livello max PHONES 2x 193 mW DIGITAL EFFECT PROCESSOR PROFEX DIGITAL EFFECT PROCESSOR PROFEX ...

Page 5: ...5 MECHANICAL DIMENSIONS DIMENSIONI MECCANICHE 36 8 cm 14 5 42 0 cm 16 5 8 7 cm 3 43 ...

Page 6: ...6 LAYOUT LAY OUT ...

Page 7: ...7 CONTROL PANEL FIG 2 PANNELLO DI CONTROLLO FIG 2 15 9 1 2 3 4 5 6 7 8 10 11 12 13 14 23 24 22 21 25 26 27 18 16 17 20 19 31 41 39 40 28 43 44 45 46 47 34 35 36 37 42 32 51 33 29 30 38 48 49 50 52 53 54 ...

Page 8: ...XLR bilanciato maschio MIC INPUT Balanced male XLR ground hot cold Ɵp leŌ ring right sleeve ground 2TRK IN OUT Jack sbilanciato 2TRK IN OUT Jack unbalanced ground hot cold nota conneƩere insieme cold e ground per cavi da bilanciato a sbilanciato note connect both cold and ground to make cable from balanced to unbalanced LINE IN OUT vari Jack sbilanciato LINE IN various OUT Jack unbalanced ground Ɵ...

Page 9: ...VD PLAYER HEADPHONES FLASH5A desktop monitors or other AUDIO SYSTEM PERSONAL COMPUTER WITH AUDIO IN OUT CAPABILITY DRUM MACHINE KEYBOARD WEDGE MONITOR or other AUDIO SYSTEM FLASH12HDA acƟve processed speaker or other AUDIO SYSTEM SAX MIC GUITAR MIC DRUMKIT MIC BASS DIRECT OUT ...

Page 10: ...60065 standard Under the EM disturbance the ra o of signal noise will be changed above 10dB PACKAGING SHIPPING AND COMPLAINT This unit package has been submi ed to ISTA 1A integrity tests We suggest you control the unit condi ons immediately a er unpacking it If any damage is found immediately advise the dealer Keep all unit packaging parts to allow inspec on Proel is not responsible for any damag...

Page 11: ... and can be driven by almost any device Specialty Y cables developed just for these jacks are widely available on shops Proel suggested type is CHLP210 See also connec on chapter on this manual 4 GAIN Control The gain control adjusts the input sensi vity of the mic and line inputs This allows the signal from mics and instruments to be adjusted to op mal internal levels If the signals are plugged i...

Page 12: ...the input sensi vity of the line inputs This allows the signal from instruments to be adjusted to op mal internal levels If the switch is up 4 dBu the input stage is set to accept high level line signals if the switch is down the input stage is set to accept low level line signals 19 EQ sec on HIGH control This control gives you up to 15dB boost or cut at 12KHz with a SHELVING curve shape Use it t...

Page 13: ...signal NOTE the preset and the varia on selected in the PROFEX effect are kept in the memory even if you turn off the mixer PRESET DESCRIPTION p 1 BRIGHT HALL This type of reverb simulates the ambience of a grand concert hall Dense smooth reverb with long pre delay and a lot of high frequency reflec ons Works well with vocals electric and acous c guitars strings The VARIATIONS vary the decay me and ...

Page 14: ...y 36 MUTE bu on Engage this switch if you want to mute the signal from the internal effect when the MUTE is engaged the PEAK LED lights ON permanently 37 FX LEVEL control It adjusts the level of the internal effect signal sent to the MAIN MIX outputs 38 FX TO AUX1 It adjusts the level of the internal effect signal sent to the AUX 1 output 39 MAIN MIX L R xlr output balanced These XLR connectors provi...

Page 15: ...vel meters are made of two columns of of eight LEDs with three colours to indicate different ranges of signal level green shows the normal opera ve level of the signal from 30 to 6 dBu yellow shows the nominal opera ve level of the signal from 0 to 6 dBu red shows a high signal level near 20 dBu CLIP level 53 48V phantom switch and LED This switch ac vates LED on and deac vates LED Off the phantom p...

Page 16: ...ard EN 55013 ed alla dire va 2006 95 CE LVD secondo lo standard EN 60065 Se so oposto a disturbi EM il rapporto segnale rumore può essere superiore a 10dB IMBALLAGGIO TRASPORTO E RECLAMI L imballo è stato so oposto a test di integrità secondo la procedura ISTA 1A Si raccomanda di controllare il prodo o subito dopo l apertura dell imballo Se vengono riscontra danni informare immediatamente il riven...

Page 17: ...10k ohms e può essere collegato ad ogni po di disposi vo con livello linea Speciali cavi Y realizza appositamente per questa uscita jack sono disponibili presso i negozi Proel suggerisce il po CHLP210 Consultare anche il capitolo delle connessioni in questo manuale 4 GAIN controllo guadagno Il controllo GAIN regola la sensibilità di ingresso dell ingresso MIC o LINE Questo perme e di regolare il s...

Page 18: ... ingresso linea destro È un conne ore po jack in grado di acce are un segnale a livello linea bilanciato o sbilanciato da ogni po di sorgente È usato solo in presenza del jack LINE LEFT per usare il canale in modalità STEREO 18 4 10 GAIN sele ore guadagno Il tasto gain regola la sensibilità dell ingresso di linea Questo perme e ai segnali degli strumen di essere regola al livello interno o male Se...

Page 19: ...ndi la manopola finché il display sme e di lampeggiare per confermare la variazione e tornare alla selezione dei preset inviare il segnale all effe o usando il controllo AUX 3 11 23 del canale a cui si vuole aggiungere l effe o regolare il controllo FX LEVEL 37 fino ad udire l effe o aggiustare i controlli AUX 3 11 23 prima della saturazione del segnale indicata dal LED di picco 35 regolare nuovament...

Page 20: ...one da 0 5Hz a 5Hz 1 16 34 TAP pulsante per impostare il tempo Quando l effe o TAP DELAY è selezionato p 9 10 15 premendo almeno due volte questo pulsante è possibile impostare il tempo di ripe zione desiderato secondo il ritmo musicale 35 PEAK rilevatore di picco Questo LED di picco lampeggia quando il segnale di ingresso dell effe o è prossimo a saturare il conver tore A D del processore PROFEX IM...

Page 21: ...L 50 C ROOM PHONES LEVEL livello uscita cuffia e c room Regola il livello delle uscite jack CONTROL ROOM e PHONES NOTA Il segnale di queste due uscite è lo stesso 51 PFL ACTIVE LED indicatore PFL a vo Questo LED segnala che uno o più tas PFL sono premu il segnale del bus PFL può essere ascoltato mediante le uscite C ROOM PHONES e visualizzato sul LED LEVEL meter 52 L R LEVEL METERS indicatori di liv...

Page 22: ...presa va inserito il cavo di alimentazione di rete del mixer Si raccomanda di u lizzare esclusivamente il cavo di alimentazione in dotazione al mixer Accertatevi che il mixer sia spento prima di inserire il cavo di alimentazione nella presa di corrente ...

Page 23: ...23 ...

Page 24: ...REV 40 14 CODE 96MAN0103 PROEL S p A World Headquarter Via alla Ruenia 37 43 64027 Sant Omero TE ITALY Tel 39 0861 81241 Fax 39 0861 887862 www proel com ...

Reviews: