PS-4700/4800 Series (Atom N270 / Core 2 Duo P8400 Pre-installed Model) User Manual
125
1
Battery / Load mode
2
Temperature
3
UPS battery unit
4
Industrial Personal Computer with integrated UPS module
5
Supply v24 Vdc
Integrated UPS Module Description
The following table gives the technical data of the UPS module integrated in the
Industrial Personal Computer with the UPS option:
Features
Values
Switching Threshold Mains / Battery
Operation
15 / 13 V
Mains Failure Bridge-over Time
Max. 20 min at 150 W load
Charging Current
Max. 0.5 A
Deep Discharge Protection
At 10 V on the battery unit
Short Circuit Protection
No
Power Requirements
Max. 7.5 W
Status Indicators
Via the system monitor
(see page 144)
Configuration
Via the system monitor settings
(see page 148)