PS-4700/4800 Series (Atom N270 / Core 2 Duo P8400 Pre-installed Model) User Manual
129
Deep Discharge Cycles
UPS Connection Cable
The UPS connection cable has two different shapes of 6-pin connectors to help
prevent a cable connector from being inserted in the incorrect connector (UPS
battery unit or Industrial Personal Computer side):
1
6-pin plug connector
2
6-pin socket connector
The following table gives the technical data for the UPS connection cable:
Features
Values
Length
3 m (9.843 ft)
Outer Diameter
8.5 mm ± 0.2 mm (0.33 in.± 0.0078 in.)
Connector Type
6-pin plug connectors, tension clamp connection
6-pin socket connectors, tension clamp connection
Wire Cross Section
Temperature Sensor Wire
Voltage Wire
2 x 0.5 mm
2
(AWG 20)
4 x 2.5 mm
2
(AWG 13)
Line Resistance
0.5 mm
2
2.5 mm
2
Max. 39
/km (63
/mile)
Max .7.98
/km (13
/mile)
Flex Radius
Fixed Installation
Free-moving
5 x wire cross-section
10 x wire cross-section
Temperature Range
Operation
Storage
– 5...+ 80
C (23 ...176
F)
– 30...+ 80
C (– 22 ...176
F)
Weight
Approx. 143 kg/km (230 kg/miles)