By integrating the charging circuit in the Industrial Personal Computer housing,
installation is reduced to merely attaching the connection cable to the UPS battery
unit mounted next to the Industrial Personal Computer.
Due to the construction of these batteries, you can store and operate the UPS
battery unit in any position.
For mounting the UPS battery unit, use the following figure as the drilling template:
Materials
Cable Shielding
Color
Thermoplastic PVC-based material
Window gray (similar to RAL 7040)
Peak Operating Voltage
12 Vdc
Testing AC Voltage
Wire/wire
1500 V
Operating Voltage
Max. 300 V
Current Load
10 A at + 20
C (10 A at + 68
F)
Features
Values