Important Information
22
Ensure that the product is properly rated for the location. If the intended location
does not presently have a Class, Division and Group rating, then users should
consult the appropriate authorities having jurisdiction in order to determine the
correct rating for that hazardous location.
In accordance with Federal, State/Provincial, and Local regulations, all hazardous
location installations should be inspected prior to use by the appropriate authority
having jurisdiction. Only technically qualified personnel should install, service, and
inspect these systems.
DANGER
EXPLOSION HAZARD
Always confirm the ANSI/ISA 12.12.01 and CSA C22.2 N
213 hazardous
location rating of your device before installing or using it in a hazardous location.
To power on or power off a Industrial Personal Computer installed in a Class I,
Division 2 hazardous location, you must either:
Use a switch located outside the hazardous environment, or
Use a switch certified for Class I, Division 1 operation inside the hazardous
area.
Do not disconnect equipment unless power has been switched off or the area
is known to be non-hazardous. This applies to all connections including power,
ground, serial, parallel, and network connections.
Never use unshielded / ungrounded cables in hazardous locations.
Use only non-incendive USB configuration.
When enclosed, keep enclosure doors and openings closed at all times to avoid
the accumulation of foreign matter inside the workstation.
Failure to follow these instructions will result in death or serious injury.
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH
Remove all power from the device before removing any covers or elements of
the system, and prior to installing or removing any accessories, hardware, or
cables.
Unplug the power cable from both the Industrial Personal Computer and the
power supply.
Always use a properly rated voltage sensing device to confirm power is off.
Replace and secure all covers or elements of the system before applying power
to the unit.
Use only the specified voltage when operating the Industrial Personal
Computer. The AC unit is designed to use 100...240 Vac input. The DC unit is
designed to use 24 Vdc. Always check whether your device is AC or DC
powered before applying power.
Failure to follow these instructions will result in death or serious injury.
Summary of Contents for PS-4700 Series
Page 1: ...PS 4700 4800 Series User Manual Atom N270 Core 2 Duo P8400 Pre installed Model...
Page 14: ...General Overview 14...
Page 62: ...Characteristics 62...
Page 86: ...Implementation 86...
Page 120: ...Configuration of the BIOS 120...
Page 138: ...Installation 138...
Page 160: ...Appendices 160...
Page 164: ...After sales service 164...