PS-4700/4800 Series (Atom N270 / Core 2 Duo P8400 Pre-installed Model) User Manual
95
Wiring and Connecting the Terminal Block
The table below describes how to connect the power cord to the DC Industrial
Personal Computer:
Marine Certification Connections
If the product is used in an environment requiring marine certification, a power line
filter must be in the power line.
For the Noise Filter for Marine Certification, please refer to "Accessories"
(
page. 161
).
Step
Action
1
Remove all power from the Industrial Personal Computer and confirm that the
DC power supply has been disconnected from its power source.
2
Remove the terminal block from the power connector and connect the power
cord to the terminal block as shown below:
Use wire with:
cross-section 0.75 mm
2
to 2.0 mm
2
(AWG 18 to AWG 14)
maximum operating temperature not less than 75
C (167
F).
3
Place the terminal block in the power connector and tighten the screws.
NOTE:
The recommended torque to tighten these screws is 0.5 N•m (4.5 lb-
in).
Summary of Contents for PS-4700 Series
Page 1: ...PS 4700 4800 Series User Manual Atom N270 Core 2 Duo P8400 Pre installed Model...
Page 14: ...General Overview 14...
Page 62: ...Characteristics 62...
Page 86: ...Implementation 86...
Page 120: ...Configuration of the BIOS 120...
Page 138: ...Installation 138...
Page 160: ...Appendices 160...
Page 164: ...After sales service 164...