Industrial Personal Computer Connections
98
Wiring and Connecting the Terminal Block
The table below describes how to connect the power cord to the AC Industrial
Personal Computer:
Step
Action
1
Confirm that the power cord is unplugged from the power supply.
2
Remove the AC terminal block from the power connector and connect the power
cord to the AC terminal block as shown below:
Use wire with:
cross-section 0.75 mm
2
to 2.5 mm
2
(AWG 18 to AWG 12)
maximum operating temperature not less than 75
C (167
F).
Attach the wire ends with screws. Use a slot screwdriver (size 0.6 x 3.5) to tighten
the connector screws. Required torque is: 0.5...0.6 N·m (4.5...5.3 lb-in).
3
Place the terminal block in the power connector at the rear side of the Industrial
Personal Computer and tighten the screws:
NOTE:
The recommended torque to tighten these screws is 0.5 N•m (4.5 lb-in).
Summary of Contents for PS-4700 Series