background image

 

 
 
 
5.Programming the Unit 

The system must be checked and tested when connections are completed. 
5.1) Check the chain support if it is halfway to make sure the movement is problem free in 

both opening and closing. 
Make sure that all the standards relative to the automatic gates and doors category 
have been observed. 

5.2) Now carry out a test of the door disconnected the motor, and open and close the door to 

verify that the mechanical parts are all in good working order and the door not bound in 
its tracks. 

5.3) Check that all the safety devices on the unit are working properly (emergency stop, photo 

beam, etc.). This is one of the most important checks and must be done with great care; in 
fact, the active safety of the automatic door depends on the correct functioning of the 
safety devices. The reversing sensitivity device is of great help in minimizing damage but 
only the correct installation of the safety devices will make it possible to stop the door 
before it can cause any damage or injury to person and/or property. 

5.4) It is now time to set the opening and closed position. 

 
 
6. Setting Open and Close Positions 

6.1) Press and hold SET until the LED displays the letter 

1. 

It turns into opening state. 

6.2) Now press UP again and hold, the door will travel to the open position, release the button 

when the door has reached the desired position. 

6.3) If the door has overrun its position, press DOWN to move the door downwards. Adjust 

the position by pressing UP and DOWN. 

6.4) Press SET to set the open position, the LED will display the letter 

2. 

Now it is the time to 

set the closed position. 

6.5) Press and hold DOWN, the door will travel to the close position, release DOWN when 

the door has reached the closed position. 

6.6) If the door has overrun its position, press the UP to move the door upwards. Adjust the 

position by pressing DOWN and UP. 

6.7) Press the SET to confirm. 
The door will now open and close automatically to map the opening and closing sensitively 
driven by force. 

WARNING: 

Keep all persons and property away from the door during the installation process. 

6.8) Now the door is set in normal operational mode. 

IMPORTANT NOTE: Safety systems must be checked regularly to ensure that maximum safety is 
maintained at all times.

 

-8-

 

Reviews: