45
PC-EWB1007_IM
23.05.16
•
Turn the residual water drain valve anti-clockwise to
drain off the rest of the water.
• Close the residual water drain valve after the resid-
ual water has been drained.
Storage
• We recommend that you keep the appliance in the
original packaging if you do not intend using it for
long periods.
• Always keep the appliance out of the reach of chil-
dren in a dry, well-ventilated place.
Troubleshooting
Problem
Possible Cause
Solution
No function.
No power supply.
Use the on / off switch (4) to turn the appliance
on.
Test the socket with another appliance.
Plug in the mains plug correctly.
Check the main circuit breaker.
The appliance is faulty.
Contact our service center or a specialist.
Compressor noisy.
Mains power supply too low.
Turn the appliance off and check the mains
power supply.
Indicator lamp
flashes.
Water refill.
Refill water “
Making Ice Cubes
”.
The ice cubes are
too small.
Surrounding temperature is too high.
Place the appliance in a cooler location.
Make sure there is adequate air circulation
around the appliance.
The water temperature is too high.
Stop the ice production. Drain some water and
refill cold water (max. 20 °C).
Smaller ice cubes are normal during the first production cycles.
Ice cubes are too
large and stick
together.
Water temperature or ambient temper-
ature too low.
Stop ice cube production.
Drain off some water and refill with lukewarm
water (max. 35 °C).
The
symbol
flashes.
The water tray is blocked by oversized
ice cubes.
Use the on / off switch (4) to turn off the appli
-
ance. Wait until the ice cubes are loosened.
Switch the appliance on again. Use
ON
to
restart.
Technical Data
Model:..................................................... PC-EWB 1007
Voltage supply: ................................
220 - 240 V~, 50 Hz
Power input: ......................................................... 0.68 A
Ice cube production: ...........................
10 - 15 kg / 24 Std.
Water tank volume: ............................
approx. 1.8 Liters
Refrigerant: .................................................
R600a / 23 g
Propellant: .............................................................C
5
H
10
Protection class: ............................................................
Climate class: ...............................................................
T
Net weight: ..........................................
approx. 10.85 kg
The right to make technical and design modifications
in the course of continuous product development
remains reserved.
This device has been tested according to all relevant
current CE guidelines, such as electromagnetic
compatibility and low voltage directives, and has
been constructed in accordance with the latest safety
regulations.
Summary of Contents for PC-EWB 1007
Page 83: ......
Page 84: ......
Page 85: ......
Page 86: ...PC EWB 1007 Stand 05 2016 PC EWB1007_IM 23 05 16 Internet www proficook de ...