background image

4 English

7. PERFORMANCE OF THE PUMP

The performance of the pump depends on the orientation of the solar panels towards the sun and their intensity. The 

max. Performance is achieved under optimum conditions. A function in the shade or under cloudy skies can not be 

guaranteed. The solar pond kits are designed primarily for use in the summer months. However, the solar panel power 

should be enough even on days in spring and autumn with excellent sunlight to operate. However, this can not be gua

-

ranteed. For models with battery operation the function of the solar pond sets the charge state of the battery depends.

Depending on the pump version allows you to customize the delivery. If a controller is available at the pump, as in the 

horizontal position is the max. achieved delivery. In a vertical position only little or no water is pumped. This model sets 

the flow rate at the control panel of the battery case.

8. BATTERY INFORMATION

 

After 12 to 18 months, you should replace the battery. For this purpose unscrew the battery cover and replace the 

 

battery with a new (replacement batteries available on request). Please note the limited implied warranty of 6 months.

Tools needed:

 

Medium sized Philips head screwdriver.

1. Remove the srews from battery box

 

2. Remove the lid and control panel from the battery box slightly.

 

3.  Disconnect the old battery from the control panel and remove it from the  

housing. Insert the new battery.

4. Carry out the assembly in reverse order.

IMPORTANT! It must be ensured that the battery cover is properly  

tightened and watertight.

With repeated charge and discharge cycles Lead-Acid and NiMh battery 

 

packs are less efficient (memory effect). This effect is much less pronounced, 

 

but still present in small mass in the Li-ion batteries used.

Through very short and frequent loading operations and many 

 

other operational influences batteries can age prematurely strong. 

 

The batteries are therefore subject to a consumable and wearing  

part of a shortened warranty of 6 months.

If you find that the battery will be less efficient, the battery needs 

 

to be fully charged. These allow the unit for 2 to 3 days (pump should 

 

not be connected) standing in the sun in order to  

allow a maximum charge the battery or use a suitable external  

charger. We recommend to occasionally repeat this procedure to extend the battery life.

If after this recharging the battery still does not meet expectations, you should replace the batteries.

NOTE: The battery is supplied charged. If the state of charge, contrary to expectations, not be sufficient to 

charge the batteries for at least 8 hours to allow sufficient charging of the battery (so damage the battery to 

avoid overcharging, the pump must be connected).

6.2 Operation from remote control

 IMPORTANT!

 

You have to press the POWER button in battery

 

box to switch on battery system first, then you

 

can select function by pressing button on the

 

remote control.

l

  (ON):

 

The Pump will be constantly on until battery runs out of all power.

l

  (2):

 

The pump will stay on for 2 hours an then switch off for 22 hours and will repeat this timing set every day at the 

same time. For example: if you want to turn on every day at 5pm, you need to turn on the pump to 2 hours timer at 

5pm. Pump will turn on every day at 5pm and turns off at 7pm.

l

  (3):

 

The pump will stay on for 3 hours an then switch off for 21 hours and will repeat this timing set every day at the 

same time. For example: if you want to turn on every day at 5pm, you need to turn on the pump to 3 hours timer at 

5pm. Pump will turn on every day at 5pm and turns off at 8pm.

l

  (4):

 

The pump will stay on for 4 hours an then switch off for 20 hours and will repeat this timing set every day at the 

same time. For example: if you want to turn on every day at 5pm, you need to turn on the pump to 3 hours timer at 

5pm. Pump will turn on every day at 5pm and turns off at 9pm.

Lid

Battery

connector (black)

Battery

Control panel

Battery box

Screws /4pc)

Battery

connector (red)

Summary of Contents for 5 001 001 008

Page 1: ...ound online Technische Änderungen Druckfehler und Irrtümer vorbehalten Aktuelle Informationen zu unseren Produkten finden Sie auf http www profi pumpe de OPERATING INSTRUCTIONS BEDIENUNGSANLEITUNG OASIS 501R 1 5 001 001 008 OASIS 801R 1 5 001 001 009 OASIS 1601R 1 5 001 001 010 OASIS 2002 1 5 001 001 011 1 OSLO 300 LIGHT 2 SP01122 2 de ORIGINAL ...

Page 2: ...ON We would like to congratulate you on the purchase of our pump We appreciate your trust That s why functional security and operational safety stands on first place for us To prevent damage to persons or property you should read this user manual carefully Please observe all safety precautions and instructions for proper use of the pump Failure to follow the instructions and safety precautions can...

Page 3: ... water tank must be emp tied rinsed with clean water and stored dry 5 ASSEMBLY INSTRUCTION 5 1 Join the bracket tubes and ground spike together and then attach the solar panel to the bracket Slide the bracket into the bracket slot in the backside of the solar panel The holding bracket holds the weight of the solar panel The direction towards the sunlight can be adjusted with the wingnut 5 2 Place ...

Page 4: ...aturely strong The batteries are therefore subject to a consumable and wearing part of a shortened warranty of 6 months If you find that the battery will be less efficient the battery needs to be fully charged These allow the unit for 2 to 3 days pump should not be connected standing in the sun in order to allow a maximum charge the battery or use a suitable external charger We recommend to occasi...

Page 5: ... and the battery to each other with any meta object such as wire l Do not disassemble or modify the battery The battery contains safety and protection devices which may cause the battery to generate heat explode or ignite if damaged l Do not place the battery in or near fire on stoves or other high temperature locations Do not place the battery iiin direct sunlight or use store the battery inside ...

Page 6: ... 2 Signed for and on behalf of Amur S à r l Remich 08 12 2022 i V Dipl Phys Peter Neumüller Technical Manager 13 GUARANTEE REGULATIONS For all manufacturer defects and material defects we grant the legal guarantee time new and unused product In such cases we take over the exchange or the repair of the pump Forwarding expenses are not carried by us The guarantee is not valid with l Material wear se...

Page 7: ...chadensminimierung weisen wir Sie hiermit ausdrücklich hin 3 INBETRIEBNAHME l Entnehmen sie alle Teile vorsichtig und kontrollieren Sie diese auf Vollständigkeit Folgende Teile müssen vorhanden sein 1x Pumpe mit 5m Kabel 1x LED Lichtring mit 5m Kabel 1x Batteriegehäuse 1x Fernbedienung enthalten bei OASIS 501R 1 OASIS 801R 1 OASIS 1601R 1 1x Solarpanel mit 2m Kabel 2x Solarpanel bei Oasis 2002 1 O...

Page 8: ...t HINWEIS Eine höhere Durchflussmenge kostet mehr Leistung und reduziert die Lebensdauer der Batterie 5 1 Verbinden Sie die Halterung die Rohre und die Bodenspit ze und befestigen Sie dann das Solarpanel an der Halte rung Schieben Sie die Halterung in den Klammerschlitz auf der Rückseite des Solarpanels Die Halteklammer hält das Gewicht des Solarpanels Die Richtung zum Sonnen licht kann mit der Fl...

Page 9: ...er als Verbrauchs und Verschleißteile einer verkürzten Gewährleistung von 6 Monaten Wenn Sie feststellen dass der Akku weniger effizient erscheint muss der Akku neu voll aufgeladen werden Dazu lassen Sie das Gerät für mindestens 8 Stunden Pumpe muß angeschlossen sein in der Sonne stehen um eine maximale Ladung der Batterie zu ermöglichen oder Sie benutzen ein geeignetes externes Lade gerät Wir emp...

Page 10: ...ithium Ionen Zellen und Akkus können heiß werden explodieren oder sich entzünden und schwe re Verletzungen verursachen wenn sie nicht bestimmungsgemäß eingesetzt werden Bitte beachten Sie unbedingt die unten aufgeführten Sicherheitshinweise l Achten Sie beim Einsetzen der Akkus unbedingt auf die richtige Polarität l Vermeiden Sie daß die positiven und oder negativen Anschlüsse und oder die Pole de...

Page 11: ...Veränderungen an den Geräten vorgenommen wurden Falls Reparaturen durch eine von uns autorisierte Servicewerkstätte vorgenommen werden haften wir nur insofern wenn Original Ersatzteile und Zubehör verwendet wurden 15 ENTSORGUNGSHINWEISE Elektro Geräte mit dem Symbol der durchgestrichenen Mülltonne dürfen nicht über den Hausmüll entsorgt werden sondern sind an einer Annahmestelle für Recycling von ...

Page 12: ...ead acid 12V 4Ah Lead acid 12V 4Ah Lead acid 12V 5Ah Cable length Kabellänge 5 m 5 m 5 m Ambient temperature Umgebungstemperatur 0 C 45 C 0 C 45 C 0 C 45 C English Deutsch OASIS 2002 1 5 001 001 011 1 OSLO 300 LIGHT 2 SP01122 2 Pump Max pump capacity Max Fördermenge 1500 l h 300 l h Max pump height Max Förderhöhe 300 cm 120 cm Max fountain height Max Höhe der Fontäne 160 cm 65 cm Max water tempera...

Page 13: ...for OASIS 501 801 Pumpe 2 für OASIS 501 801 A135 SP03101 Solar panel for OASIS 501R 1 Solarpanel für OASIS 501R 1 A3373 SP02211 Solar panel for OASIS 801R 1 Solarpanel für OASIS 801R 1 A6778 SPZ03142 Solar panel for OASIS 1601 Solarpanel für OASIS 1601 A6781 Solar panel for OASIS 2002 Solarpanel für OASIS 2002 A136 SP03101 LED light ring 4 5x1 7 4V LED Licht Ring 4 5x1 7 4V A6721 SPZ03129 For tech...

Page 14: ...14 Notes Notizen ...

Page 15: ...Notes Notizen 15 ...

Page 16: ...Imprint Impressum Amur S à r l www amur lu Email info amur lu Tel 49 0611 9 45 87 77 0 Fax 49 0611 9 45 87 77 11 de ORIGINAL ...

Reviews: