background image

2 English

English 3

2. in General

The pumps are high-quality pump systems for outdoor or indoor use. 

2.1 It‘s recommended NOT to conduct yourself technical modifi cations. First, it is not certain 

whether these changes are technically correct and, secondly, because no guarantee can be 

granted.
2.2 Transport damages are immediately to be reported to the package distributor and to us in 

written form. Failure to give timely notice to the shipping company, and are therefore rejected 

your claims from the transport company, so we can not accept these claims as well. In your 

legal obligation to cooperate to minimize damage, we point out expressly herewith.

1. introduction

We would like to congratulate you on the purchase of our pump. We appreciate your trust. 

That‘s why functional security and operational safety stands on fi rst place for us.

 

 to prevent damage to persons or property, you should read this user manual care-

fully. please observe all safety precautions and instructions for proper use of the 

pump. failure to follow the instructions and safety precautions can result in inju-

ry or property damage. please keep this manual with the instructions and safety 

instructions carefully in order to at any time you can restore them.

3. aSSemblinG

l

   Unpack all components carefully. You should have received the following parts:

1 pc Adapter with 2m cable; 1pc Pump with 5m cable; 1pc LED light with 1.5 cable

l

   To protect the product, place all parts on a soft surface before assembly.

The pump now can be adjusted with the 

regulator, this is found on the inlet of the 

pump. We recommend starling with the 

fl ow regulator fully open and then adju-

sting dawn if required.

Regulator

Anti clock wise:

FULL FLOW

Clock wise:

REDUCED FLOW

note:  if outdoors the electrical outlets muSt be waterproof to 

ip44 standard.

note:  we recommend the use of a residual current device (Gfi) 

Ground fault interrupter (available from al good d.i.y. stores), 

when connecting the adapter to the electric supply.

Safety inStruction and warninGS

Please read the user manual 

before using the device

Pull power plug

Warning sign

Warning of electrical voltage

contents

  1.  Introduction  .........................................................................................................................  2

  2.  In general  ............................................................................................................................  2

  3.  Assembling  .........................................................................................................................  2

  4.  Maintenance ........................................................................................................................  3

  5.  Security tips  ........................................................................................................................  3

  6.  Guarantee regulations  .........................................................................................................  4

  7.  Problem Shooting ..................................................................................................................... 5

  8.  Notes on Product Liability  ...................................................................................................  5

  9.  Notes on Disposal  ...............................................................................................................  5

10.  EU Declaration of Conformity  .............................................................................................  5

11.  Technical Data  ..................................................................................................................  12

12.  Available accessories and spare parts  .............................................................................. 12

4.2 FROST

Frost can cause damage to the fountain. In freezing the pump and pipes must 

be emptied, rinsed with clean water and stored dry.

4. maintenance

4.1 If you fi nd the pump start losing 

power or stop working, please clean the 

pump fi lter and impeller with clean water.

1. Front case

2.  Impeller 

cover

3. Impeller

4. Pump

3.1 Connect the two ends of the LED 

lighting wires together and screw over 

the plastic collar. Push the cable with two 

pins into the adapter and screw over the 

plastic collar.

3.2 Put the pump in water, make sure the 

pump is fully submerged in water. The 

connector the plug from adapter into 

proper electrical outlets.

5. Security tipS

 

l

 Obey absolutely valid regulations on the electrical security 

 

l

 Never run pump dry

 

l

 Pumping infl ammable, as well as all other aggressive liquids is prohibited

 

l

 Pay attention to the medium temperature max. 35°C

 

l

  The mains plug must be disconnected before carrying out any work on the pump

 

l

 Never pull the pump on the electrical cable or hose

 

l

 Avoid cross section narrowing

 

l

 Pay attention to the particle size 

 

l

  During longer unused times, clean the pump, wash it out with clear water, dry and store 

it at room temperature

 

l

 Test wells for enough fl owing water (dry run danger)

Summary of Contents for JR-800LV

Page 1: ...echnical changes misprints and mistakes reserved Newest information about our products can be found online Technische Änderungen Druckfehler und Irrtümer vorbehalten Aktuelle Informationen zu unseren Produkten finden Sie auf http www profi pumpe de tauchpumpe für SprinGbrunnen und teich SPZ03126 ...

Page 2: ...LOW note if outdoors the electrical outlets muSt be waterproof to ip44 standard note we recommend the use of a residual current device Gfi Ground fault interrupter available from al good d i y stores when connecting the adapter to the electric supply Safety inStruction and warninGS Please read the user manual before using the device Pull power plug Warning sign Warning of electrical voltage conten...

Page 3: ...responsibility for the damages which originate from the improper use of the device 6 Guarantee regulations For all manufacturing and material defects the statutory warranty applies In these cases we take the replacement or repair of the device Shipping costs shall be borne by our company except as 7 Problem Shooting l Check all cable connections l Check water level make sure the pump is fully subm...

Page 4: ... Packen Sie alle Komponenten sorgfältig aus Sie sollten die folgenden Teile erhalten haben 1x Adapter mit 2m Kabel 1x Pumpe mit 5m Kabel 1x LED Leuchte mit 1 5m Kabel l Um das Produkt zu schützen legen Sie alle Teile vor der Montage auf eine weiche Unterlage Die Pumpe kann nun mit dem Regler eingestellt werden dieser befindet sich am Eingang der Pumpe Wir empfehlen den Volumenstromregler zunächst ...

Page 5: ...chtigung durchgeführt werden Der Hersteller erklärt l keine Verantwortung im Fall von Unfällen oder Schäden aufgrund von Fahrlässigkeit oder Missachtung der Anweisungen in dieser Anleitung zu übernehmen l jede Verantwortung für Schäden die durch die unsachgemäße Verwendung der Pumpe ent stehen abzulehnen 6 Garantiebestimmungen Für alle Fabrikations und Materialfehler gilt die gesetzliche Gewährlei...

Page 6: ...tische Verträglichkeit 2014 30 EG Folgende harmonisierte Normen EN 55032 2015 EN 55032 2012 EN 55020 2007 A12 2016 EN 55015 2013 A1 2015 EN 55015 2013 EN 61547 2009 EN 55014 1 2006 A2 2011 EN 55014 2 2015 EN 55014 2 1997 A2 2008 EN 61000 3 2 2014 EN 61000 3 3 2013 Wiesbaden den 12 11 2017 ppa Peter Neumüller Notes Notizen 11 ...

Page 7: ...ion grade Schutzklasse IPX8 Length of cable Kabellänge 5m Adapter Input Einspeisung 230V 50Hz Output Ausgangsleistung 12V 1800mA 21 6VA Protection grade Schutzklasse IP67 Length of cable Kabellänge 2m LED Quantity Anzahl 1x4 LEDs Colour Farbe white weiß Protection grade Schutzklasse IP68 Length of cable Kabellänge 1 5m 12 AVAILABLE ACCESSORIES AND SPARE PARTS Further accessories and spare parts fo...

Reviews: