background image

8 English

13. NOTES ON DISPOSAL

Electro devices of our company, labeled with the symbol of the crossed trash bin, 

are not permitted to be disposed in your household garbage. We are registered at 

the German registration department EAR under the 

WEEE-No. DE79535656.

 This 

symbol means, that you’re not allowed to treat this product as a regular household 

waste item – it has to be disposed at a recycling collection point of electrical de

-

vices. This is the best way to save and protect our earth.

THANK YOU FOR YOUR SUPPORT! 

In connection with the sale of batteries or with the delivery of equipment containing 

rechargeable battery packs, the seller is obliged to draw your attention to the following:

You are obliged to return used batteries as an end-user. You can return batteries af-

ter use to the seller or to the designated collection facilities, which are free of charge 

(eg: municipal collection points or in stores). You can return the batteries for disposal 

at no charge to the seller.

14. EU DECLARATION OF CONFORMITY

The undersigned, Amur S.à r.l., 36, Rue de la Gare, L-5540 Remich, certifies that the product 

named overleaf, namely „OASIS 200-3“ OR „OASIS 500-3“ OR „OSLO 900“ OR „OXYGEN-3“

as placed on the market, complies with the relevant provisions listed below, the relevant EU 

 

harmonised directives and the EU standard for safety. This declaration of conformity applies 

insofar as no modifications are made to the product. The sole responsibility for issuing this 

 

declaration of conformity lies with the manufacturer.

The sole authorised person to keep the technical documents:

Amur S.à r.l. - 36, Rue de la Gare - L-5540 Remich

EC Electromagnetic compatibility directive (2014/30/EU) 

The following harmonized standards:

EN 55014-1:2017; EN 55014-2:2015; ROHS: 2011/65/EU; BS EN 55014-1:2017 / DIN BS EN 

55014-1; BS EN 55014-2:2015 / DIN BS EN 55014-2

Signed for and on behalf of:

Amur S.à r.l.

Remich, 14.12.2022

i.V. Dipl. Phys. Peter Neumüller

Technical Manager

 

   

Summary of Contents for OASIS 200-3 LI+LED

Page 1: ... our products can be found online Technische Änderungen Druckfehler und Irrtümer vorbehalten Aktuelle Informationen zu unseren Produkten finden Sie auf http www profi pumpe de OPERATING INSTRUCTIONS BEDIENUNGSANLEITUNG OASIS 200 3 Li LED SP01121 3 OASIS 500 3 Li LED SP01123 3 OXYGEN 3 SP01120 3 Oslo 900 SP01135 de ORIGINAL ...

Page 2: ...oor use The perfect eye catcher in your garden or seed tray Through the use of high quality solar technology is the Solar Pond Pump Kits mains independent and any where to use immediately 2 1 It s recommended NOT to conduct yourself technical modifications First it is not cer tain whether these changes are technically correct and secondly because no guarantee can be granted 2 2 Transport damages a...

Page 3: ...nel angle to maximise the amount of solar energy collected Summer 0 30 Spring Autumn 30 60 3 2 Connect the pump panel and the LED Light on the battery see illustration Check whether the flow is fully open or else promoted little or no water IMPORTANT Slightly twist the connectors when pushing Solar pond pump Oasis 500 3 Li LED Solar pond pump Oasis 200 3 Li LED Solar Oxygenator OXYGEN 3 Solar pond...

Page 4: ...protect battery don t manually turn on the pump frequently Note The indicator light is solid when charging battery Model Oasis 200 3 Li LED The model can be loaded with a 5V charger Model Oasis 500 3 Li LED The model can be loaded with a 9V charger The solar set is operating in solar powered mode until you turn on the pump by pressing the Battery mode button In Battery mode the LED light automatic...

Page 5: ...ational influences batte ries can age prematurely strong The batteries are therefore subject to a consumable and wearing part of a shortened warranty of 6 months If you find that the battery will be less efficient the battery needs to be fully charged These allow the unit for 2 to 3 days pump should not be connected standing in the sun in order to allow a maximum charge the battery or use a suitab...

Page 6: ...the specified voltage is pro vided Operate the pump to an external battery Pump runs but no water is en couraged Pump impeller and filter hou sing polluted Disassemble and clean in accordance with point 5 the pump and the housing by means of water and a soft brush The flow regulator on the pump is closed Open the flow regulator on the pump Coarsining or fountain noz zles dirty Disassemble and clea...

Page 7: ...on THE MANUFACTURER EXPLAINS l To take over no responsibility in the case of accidents or damages on the basis of careless ness or disregard to the instructions in this manual l To reject every responsibility for the damages which originate from the improper use of the device 12 GUARANTEE REGULATIONS For all manufacturing and material defects the statutory warranty applies In these cases we take t...

Page 8: ...ge eg municipal collection points or in stores You can return the batteries for disposal at no charge to the seller 14 EU DECLARATION OF CONFORMITY The undersigned Amur S à r l 36 Rue de la Gare L 5540 Remich certifies that the product named overleaf namely OASIS 200 3 OR OASIS 500 3 OR OSLO 900 OR OXYGEN 3 as placed on the market complies with the relevant provisions listed below the relevant EU ...

Page 9: ...ren Bitte bewahren Sie die Bedienungsanleitung mit den Anweisungen und Sicherheitshin weisen sorgfältig auf um jederzeit darauf zurückgreifen zu können Bitte laden Sie stets die neueste Ausführung der Bedienungsanleitung von www profi pumpe de unter download herunter Diese ist stets maßgebend SICHERHEITSHINWEISE UND WARNUNGEN Bitte lesen Sie vor Inbetriebnahme der Pumpe die Bedienungsanleitung All...

Page 10: ...rpanel so dass es direktes Sonnenlicht erhält Die Pumpe Be lüfter kann nicht funktionieren wenn die Solarzelle beschattet wird Passen Sie den Winkel des Solarpanels an Sommer 0 30 Frühjahr Herbst 30 60 3 2 Schließen Sie die Pumpe Belüfter und das Solarpaneel an siehe Abbildung Kontrollieren Sie ob der Durchflussregler an Pumpe Belüfter komplett geöffnet ist sonst wird kein oder nur wenig Wasser ge...

Page 11: ... 2 6 Std Rot Batterie muß geladen werden Pumpe arbeitet weniger als 1 Std Hinweis Um die Batterie zu schützen die Pumpe nicht zu häufig manuell starten Hinweis Die Anzeige leuchtet stetig wenn der Akku aufgeladen wird Modell Oasis 200 3 Li LED Das Modell kann mit einem 5V Ladegerät geladen werden Modell Oasis 500 3 Li LED Das Modell kann mit einem 9V Ladegerät geladen werden Das Solarset arbeitet ...

Page 12: ... stark altern Die Akkus unterliegen daher als Verbrauchs und Verschleißteile einer verkürzten Gewährleistung von 6 Monaten Wenn Sie feststellen dass der Akku weniger effizient erscheint muss der Akku neu voll aufgeladen werden Dazu lassen Sie das Gerät für mindestens 8 Stunden Pumpe muß angeschlossen sein in der Sonne stehen um eine maximale Ladung der Batterie zu ermöglichen oder Sie benutzen ein...

Page 13: ... bei einem Akku Flüssigkeit austritt und mit Ihrem Auge in Berührung kommt nicht das Auge reiben gut mit Wasser spülen und sofort einen Arzt aufsuchen Wenn das Auge nicht so fort behandelt wird kann die Batterie flüssigkeit zu schweren Verletzungen des Auges führen 10 ERKENNEN UND BEHEBEN VON FEHLERN Problem Mögliche Ursache Lösung Pumpe schaltet sich nicht ein Keine Sonneneinstrahlung Solarpanel ...

Page 14: ...ntwortung im Fall von Unfällen oder Schäden aufgrund von Fahrlässigkeit oder Missachtung der Anweisungen in dieser Anleitung zu übernehmen l jede Verantwortung für Schäden die durch die unsachgemäße Verwendung der Pumpe ent stehen abzulehnen 12 GARANTIEBESTIMMUNGEN Für alle Fabrikations und Materialfehler gewähren wir die gesetzliche Gewährleistung neue und ungebrauchte Ware In solchen Fällen über...

Page 15: ...losen Entsorgung an den Verkäufer zurücksenden 15 EU KONFORMITÄTSERKLÄRUNG Der Unterzeichner Amur S à r l 36 Rue de la Gare L 5540 Remich bestätigt dass das umseitig benannte Produkt nämlich OASIS 200 3 ODER OASIS 500 3 ODER OSLO 900 ODER OXYGEN 3 in der in den Verkehr gebrachten Ausführung den unten aufgeführten einschlägigen Bestimmungen den entsprechenden EU harmonisierten Richtlinien und dem E...

Page 16: ...P68 Battery Type Batterie Typ Lithium 3 7V 2000mAh Lithium 7 4V 2000mAh Cable length Kabellänge 5 m 5 m Ambient temperature Umgebungstemperatur 0 C 45 C 0 C 45 C Oslo 900 SP01135 OXYGEN 3 SP01120 3 Pump Max pump capacity Max Fördermenge 800 l h 200 l h Max pump height Max Förderhöhe 140 cm 40 cm Max water temperature Max Wassertemperatur 40 C 40 C Solar module Rated voltage Nennspannung 9 V 5 V Am...

Page 17: ...are Part Pump 8 für Oasis 200 3 For technical information see section 16 Spare Part Pump 8 für Oasis 200 3 Technische Informationen siehe Punkt 16 A7329 SP031011 Spare Part Pump 8 für Oasis 500 3 For technical information see section 16 Spare Part Pump 8 für Oasis 500 3 Technische Informationen siehe Punkt 16 A7330 SP031010 LED light ring 5 LED Licht Ring 5 A7333 SPZ03147 Ground Spike 3 Bodenspitz...

Page 18: ...18 Notes Notizen ...

Page 19: ...Notes Notizen 19 ...

Page 20: ...Imprint Impressum Amur S à r l www amur lu Email info amur lu Tel 49 0611 9 45 87 77 0 Fax 49 0611 9 45 87 77 11 de ORIGINAL ...