background image

Contents

  1. Introduction  ..........................................................................................................................  2

  2. In general .............................................................................................................................  2

  3. Operation  .............................................................................................................................  3

  4. Installation  ...........................................................................................................................   3  

  5. Cut in pressure adjustment ..................................................................................................  3

  6. Functional parts  ...................................................................................................................  4

  7. Commisioning  ......................................................................................................................  4

  8. Protection against dry running  .............................................................................................  4

  9. Automatic reset  ....................................................................................................................  4

10. Security tips ..........................................................................................................................  4

11. Servicing  ..............................................................................................................................  5

12.  Guarantee regulations  ........................................................................................................  5

13.  Recognising and repairing of mistakes  ...............................................................................  6

14.  Notes on Product Liability  ..................................................................................................  6

15.  Notes on Disposal  ..............................................................................................................  6

16.  EU Declaration of Conformity  ............................................................................................  6

17.  Technical Data  .................................................................................................................  12

18.  Electrical Installation  ........................................................................................................  12

4. InstallatIon

The installation must be performed by a qualified professional.

 

l

  The device is installed at any point between the outlet of the pump and the first collector, so that 

the direction of the arrow on the side between the two 1 „connections with the flow direction of the 

fluid in the pipeline matches. Make sure that the hydraulic connections are completely sealed. If a 

pump with maximum pressure used above 10 bar, a pressure reducer at the entrance of the de-

vice must be installed. The pump controller is to be used only for pumps that produce a minimum 

pressure of 2.5 bar at the device installation point.

l

  The electrical connection of the unwired version is after the electrical diagram (see paragraph. 18) 

produce. If a consumer is used with a power more than 1.1 kW and the ambient temperature is 

higher than 25 °C, must be used for the wiring is not less than 99 °C cable with heat resistance. 

For wiring, only use this specific pliers. When ready to plug in wired version, it is sufficient to 

connect the power cord of the pump with the outlet of 5.2 and shut the power plug of 5.2 to an 

electrical outlet the power grid on.

 

l

  The pressure at which the device starts is set to 1.5 bar, this pressure is optimal for most applica-

tions. It can be changed by an expert by means of setting screw.

l

 The height of the water column above the 5.2 should not exceed 10m.

Warning: no additional check valve should be installed between the pump and  

the 5.2, as it sometimes causes problems.

2 English

English 3

safety InstruCtIon and WarnIngs

Please read the user manual 

before using the device

Pull power plug

Warning sign

Warning of electrical voltage 

1. IntroduCtIon

We would like to congratulate you on the purchase of our flow switch. We appreciate your trust. 

That‘s why funtional security and operational safety stands by us on first place.

to prevent damage to persons or property, you should read this user manual 

carefully. Please observe all safety precautions and instructions for proper use 

of the 5.2. failure to follow the instructions and safety precautions can result in 

injury or property damage.

Please keep this manual with the instructions and safety instructions carefully in 

order to at any time you can restore them. Please always download the latest ver-

sion of the user manual of www.profi-pumpe.de under „downloads“. This shall 

always prevail.

2. In general

The 5.2 is a circuit device that an electrical load (pump) automatically switches on and off. The 

device monitors the pressure and the flow in the pressure line. Depending upon the pressure or 

the flow rate, the AC switches one or more electrical consumers (MAX 10A) on and off.

The manometer indicates the pressure in the system. It helps to monitor the proper pump func-

tion and to detect leaks in the system.

The device can continue to restart the pump automatically by means of a timer to check if water 

is available again (only for versions with automatic reset).

3. oPeratIon

The appliance activates the pump for about 15 seconds when it is powered. The pump starts eve-

ry time it senses a pressure drop within the system, for example when a tap is opened.

Unlike traditional water system equipped with pressure switch and pressure tank, it is the mi-

nimum flow that determines when the pump should stop, rather than the cut-out pressure. The 

device delays the pump from stopping for a further 7 – 15 seconds, thus reducing pump cycling in 

low flow conditions.

5. Cut-In  Pressure adJustMent

CautIon: turning the adjustment screw WIll not alter the maximum pressure 

delivered by the pump!

The pressure is factory pre-set at 1.5 bar, which is optimal for most applications. Different working 

pressures may be obtained by adjusting the screw on the inner flange, which is marked by the 

s and -.

You may need to change the factory-adjusted pressure settings:

l

  If the tap situated at the highest point is more than 15 metres above the 5.2 (Hmax: 30 mt)

l

  For increased load, i.e. when the load pressure is added to the pump pressure (max. 10 bar).

 

  CautIon: It is important that the MaXIMuM Pressure of the PuMP is at least  

0,6 Bar HIgHer tHan the cut-in pressure set  on tHe 5.2 device.

l

    The 5.2 is to be used exclusively for non abrasive clear water without debris and other dirt. In 

the opposite case, an effective pre-filter with a mesh size should be installed no coarser than 

0.2 mm in front of the device.

l

    It is not recommended to install the unit in wells or in dense enclosures, as strong condensa-

tion may occur. If there is a risk of ice forming due to low ambient temperatures, it is recom-

mended to protect 5.2 and the pump accordingly.

Make sure after unpacking that the data given on the nameplate agree with the foreseen opera-

ting conditions. When in doubt, the operation is prohibited.

Transport damages are reported immediately to the transport company and to us in writing.

Summary of Contents for PSM01122V

Page 1: ... BedIenungsanleItung de Technical changes misprints and mistakes reserved Newest information about our products can be found online Technische Änderungen Druckfehler und Irrtümer vorbehalten Aktuelle Informationen zu unseren Produkten finden Sie auf http www profi pumpe de 2 DURCHFLUSSWÄCHTER 5 2 AUTOMATIC CONTROLLER UNVERKABELT PSM01121U ...

Page 2: ...perty damage Please keep this manual with the instructions and safety instructions carefully in order to at any time you can restore them Please always download the latest ver sion of the user manual of www profi pumpe de under downloads This shall always prevail 2 In General The 5 2 is a circuit device that an electrical load pump automatically switches on and off The device monitors the pressure...

Page 3: ... water source When Flow guard is used for swimming pools ponds and fountains if is necessary to use an automatic RCD with IDn 3OmA protection 7 COMMISSIONING CAUTION If the water level happens to be below the level at which the pump is installed negative head it is imperative to use a suction hose complete with foot valve to prevent water from draining back into the well Before switching on make s...

Page 4: ... beglückwünschen Wir wissen Ihr Vertrauen zu schätzen Aus diesem Grund stehen bei uns Funktions und Be triebssicherheit an erster Stelle Um Personen und Sachschäden zu vermeiden lesen Sie die vorliegende Bedie nungsanleitung bitte aufmerksam durch Bitte beachten Sie alle Sicherheitshin weise und Anweisungen zum sachgemäßen Gebrauch des 5 2 Eine Nichtbeach tung der Anweisungen und Sicherheitshinwei...

Page 5: ...edrigem Fluss weniger häufig eingreift 5 EINSTELLUNG DES STARTDRUCKS Der Einschaltdruck ist auf 1 5 bar voreingestellt ein optimaler Wert für die meisten Anwendungen Mit der Schraube auf dem Innenflansch mit den Symbolen und können andere Einschaltdrücke eingestellt werden Es kann nötig sein den Einschaltdruck zu regulieren l wenn der Wasserhahn mit dem höchsten Verbraucher mehr als 15 Meter über ...

Page 6: ...unzuläs sig und führt stets zum Verlust der ggf bestehenden Garantieansprüche Darüber hinaus können erhebliche Gefahren beim Betrieb einer taktenden Pumpe entstehen so dass die Pumpe unter keinen Umständen weiter betrieben werden darf Bis zum Geräteaustausch ist die Pumpe außer Betrieb zu setzen Bei abrasiven Materialien wie Sand verkürzt sich die Wartungsdauer und die Gerätelebensdauer Folgende K...

Page 7: ...yellow grün gelb Erde 6 Power Netz n blue blau Null The device is normally connected as shown in figure Pumps can be operated on the device with higher performance with a current consumption over 10A and even three phase pumps In this case the connection means of a suitable circuit protection is provided more information can be found on our Internet site Das Gerät wird im Normalfall gemäß Abbildun...

Reviews: