background image

5. secuRity tips

 

l

 Obey absolutely valid regulations on the electrical security 

 

l

 Never run pump dry

 

l

 Pumping inflammable, as well as all other aggressive liquids is prohibited

 

l

 Pay attention to the medium temperature max. 35°C

 

l

 Never pull the pump on the electrical cable or pressure hose

 

l

 Avoid cross section narrowing

 

l

 Pay attention to the given particle size 

 

l

  During longer unused times, clean the pump, wash it out with clear water, dry and store 

it at room temperature

 

l

 Test wells for enough flowing water (dry run danger)

 

l

  The pump is to be secured through a RCD circuit  breaker with a release current  

of 30 mA.

 

l

  The electrical connections are always to be carried out by an authorised professional

 

l

  Operation can not be performed by children and young people under 16 and  

people with intellectual disabilities

 

l

  The pump may be used by children aged 8 years and above as well as persons with 

reduced physical, sensory or mental abilities or those who lack skills, experience and 

knowledge only if they are supervised. These aforementioned persons should only use 

the appliance while adhering to safe instructions and resulting dangers.

 

l

  Cleaning and maintenance must not be carried out by children without supervision.

 

l

  The pump must not be used or operated under any circumstances when there are  

people in the same water.

 

l

  Under certain cirumstances, it is possible that that contamination of water is caused  

by leakage.

the ManufactuReR explains:

l

  To take over no responsibility in the case of accidents or damages on the basis of careless-

ness or disregard to the instructions in this book.

l

  To reject every responsibility for the damages which originate from the improper use of the 

pump.

6. seRvicing

 

 Under normal pumping conditions the pump requires no servicing. From an operating 

period (with clear water) of approx. 2000 hours the mechanical components should be 

checked: impeller wheels, chambers, sealing rings etc. on wear and if necessary be 

changed. After 3000 pumping hours the oil in the chamber should also be changed, if 

necessary (only with oil-dipped engine types!). Please, only fill it up to 80% and check 

the sealing rings always for density.

 

With abrasive materials like sand the servicing duration can become shorter.

 

The following controls should be carried out regularly:

 

l

 Intactness of the electric cable

 

l

 That the connection hoses are not bent or broken

 

l

 Cleanness of the pump medium 

 

 Moreover, the pump should be emptied with risk of frost, be washed out with clear water 

and stored dry.

7. guaRantee Regulations

For all manufacturing and material defects, the statutory warranty applies. In these cases we 

take the replacement or repair of the pump. Shipping costs shall be borne by our company, 

except as required by law. Please report the warranty on our service platform http://www.profi-

pumpe.de/service.php. We will inform you how to proceed with case-related. Returns please 

sufficient postage. Unfortunately not prepaid returns can not be accepted because they are 

filtered out before delivery. Our service we provide in Germany.

The warranty does not cover:

l

 Material wear (sealing rings, impeller wheels, impeller chambers)

l

 Unjustified interventions or changes in the pump

l

 Damages by selffault

l

 Improper servicing and improper use

l

 DRY RUNNIG (Also partially!) of the pump

Moreover, we give no damage compensation for secondary damages!

8. Recognising and RepaiRing of Mistakes

problem

possible cause

solution

Pump runs, no water 

is being pumped

Air in the suction line

Check suction line and connec-

tions for vacuum tightness

Air in the system (cannot escape)

Air in the system must be let out

Impeller wheel is blocked

Impeller wheel must be cleaned

Pump does not start 

or switches itself off

Engine guard has switched the 

pump off

Pump needs to be cooled

No electricity

Check electrical connections

Pump runs, Pump 

capacity slows down 

or stops

Pump is inserted to deep

Insert pump not so deep

Hose connections systems have a 

leak

Check hose connection systems

Impeller wheel is worn down

Change impeller wheel

Filter has become dirty

Clean filter

When you turn on the 

pump, RCD circuit 

breaker is triggered

Pump could have a leak

Check pump for moisture dama-

ge

Condensation in the electrical con-

nection / junction box

Unplug the pump / contact the 

distributor

9. notes on pRoduct liability 

We point out, that we are only liable for damages under the Product Liability Act, which are 

caused by our units if no changes were made to the equipment. If repairs are carried out by our 

authorized service, we are only liable if original spare parts and accessories were used.

4 English

English 5

Summary of Contents for REGEN-STAR REGENTONNE 400

Page 1: ...ved Newest information about our products can be found online Technische Änderungen Druckfehler und Irrtümer vorbehalten Aktuelle Informationen zu unseren Produkten finden Sie auf http www profi pumpe de opeRating instRuctions bedienungsanleitung de 1 Regen staR Regentonne 400 TP04101 2 Regen staR supeR 350 TP04100 ...

Page 2: ...t from the pump and seal We recommend that you execute the line in one piece without interruption in order to avoid leaks Check valve and water pipes for leaks at least by means of pres sure testing 24h test Can we expect dirt in the pump an effective pre filter should be installed upstream of the pump Electrically connect pump with power supply Fill pump and suction pipe with water usually done t...

Page 3: ...rvicing duration can become shorter The following controls should be carried out regularly l Intactness of the electric cable l That the connection hoses are not bent or broken l Cleanness of the pump medium Moreover the pump should be emptied with risk of frost be washed out with clear water and stored dry 7 Guarantee regulations For all manufacturing and material defects the statutory warranty a...

Page 4: ... Fehlern 10 9 Hinweise zur Produkthaftung 11 10 Entsorgungshinweise 11 11 EU Konformitätserklärung 11 12 Technische Daten 12 2 Allgemeines Die Pumpen sind nach dem neuesten Stand der Technik entwickelt mit größter Sorgfalt gefertigt und unterliegen strengen Qualitätskontrollen Die Pumpen wurden von uns insbesondere für die speziellen Anforderungen der Regenwasser nutzung optimiert Vergewissern Sie...

Page 5: ...Lebensdauer entsprechend Pumpe niemals mehr als 5 Minuten gegen ein geschlossenes Ventil laufen lassen Pumpe gegen Trockenlauf entspre chend sichern Trockenlaufschutz installieren Pumpe niemals mehr als 20mal pro Stunde starten und stoppen Beim Takten der Pumpe entfällt jeglicher Anspruch auf Gewährleistung Nicht für Betrieb an Solar Photovoltaik anlagen geeignet Die Pumpe darf nicht in Schwimmbäd...

Page 6: ...icht geworden Pumpe auf Feuchtigkeitsschäden untersuchen Kondensatbildung im elektrischen Anschluss Klemmkasten Vom Stromnetz trennen Lieferanten informieren 8 Erkennen und Beheben von Fehlern 9 Hinweise zur Produkthaftung Wir weisen darauf hin dass wir nach dem Produkthaftungsgesetz für Schäden die durch unsere Geräte verursacht werden nur insofern haften soweit keine Verände rungen an den Geräte...

Page 7: ...350 W Max pump capacity Max Fördemenge 5800l h 2400l h Max pressure Max Druck 0 7 bar 0 7 bar Max pump height Max Förderhöhe 7 m 7 m Max water temperature Max Wassertemperatur 35 C 35 C Max suction height Max Ansaughöhe tba folgt 8 m Max submersion depth Max Eintauchtiefe 7 m 7 m Protective class Schutzklasse IP68 IP68 Tension Spannung 230V 50 Hz 230V 50 Hz Diameter in cm Durchmesser in cm 14 7 18...

Reviews: