6 English
Deutsch 7
13. NOTES ON PRODUCT LIABILITy
We point out, that we are only liable for damages under the Product Liability Act, which are caused by our units if no
changes were made to the equipment. We are only liable for repairs, if original spare parts and accessories were
used and repairs are carried out by our authorized service.
14. NOTES ON DISPOSAL
Electro devices of our company, labeled with the symbol of the crossed trash bin, are not permitted to
be disposed in your household garbage. We are registered at the German registration department EAR
under the
WEEE-No. DE25523173.
This symbol means, that you’re not allowed to treat this product as a
regular household waste item – it has to be disposed at a recycling collection point of electrical devices.
This is the best way to save and protect our earth.
THANK yOU FOR yOUR SUPPORT!
In connection with the sale of batteries or with the delivery of equipment containing rechargeable battery
packs, the seller is obliged to draw your attention to the following:
You are obliged to return used batteries as an end-user. You can return batteries after use to the seller
or to the designated collection facilities, which are free of charge (eg: municipal collection points or in
stores). You can return the batteries for disposal at no charge to the seller.
15. EU DECLARATION OF CONFORmITy
The undersigned 1A Profi Handels GmbH, Unterriethstr. 37, 65187 Wiesbaden confirms, that the products placed
on the market execution referred to the relevant regulations below, the relevant EU directives and harmonized corre-
sponds to the EU standard for security.
This declaration is valid insofar as no changes to the product are made.
Authorized person to keep the technical documents:
1A-Profi-Handels GmbH · Unterriethstraße 37 · D-65187 Wiesbaden
Low Voltage Directive (2006/95/EC)
EC Electromagnetic compatibility directive (2004/108/EC)
The following harmonized standards:
EN 55014-1:2006; EN 55022:2006; EN 55014-2:1997+A1:2001
Wiesbaden, 2nd March 2016
Peter Neumüller
Problem
Possible cause
Solution
Pump will not turn on
No sunlight
The orientation of the solar panels up to
the sun
Low charge level of the battery
See item 7 and 8 (Note)
Pump connector is not connected correctly
See item 5.6
Defective pump / solar panel broken
Replace pump or solar panel
Pump runs but no water
is encouraged
Pump impeller and filter housing polluted
Disassemble and clean in accordance with
point 10, the pump and the housing (by
means of water and a soft brush)
The flow controller to the pump is closed
Open the flow regulator on the pump
Pump has sucked air
Turn off the pump briefly and then back on
(restarting)
Attention! Avoid dry running
Coarsining or fountain nozzles dirty
Disassemble and clean the tube and the
fountain nozzle
12. RECOGNISING AND REPAIRING OF mISTAKES
INHALT
1. Vorwort ............................................................................................................................................................... 8
2. Allgemeines ........................................................................................................................................................ 8
3. Inbetriebnahme .................................................................................................................................................. 8
4. Frost .................................................................................................................................................................... 8
5. Aufbauanleitung ................................................................................................................................................. 8
6. Leistung der Pumpe ............................................................................................................................................ 9
7. Warnhinweise zum Akku .................................................................................................................................... 9
8. Akku wechseln ................................................................................................................................................... 9
9. Sicherheitshinweise .......................................................................................................................................... 10
10. Wartung
............................................................................................................................................................ 10
11. Garantiebestimmungen
.................................................................................................................................... 10
12. Erkennen und Beheben von Fehlern ................................................................................................................ 11
13. Hinweise zur Produkthaftung ........................................................................................................................... 11
14. Entsorgungshinweise
....................................................................................................................................... 11
15. EU-Konformitätserklärung ................................................................................................................................ 11
16. Technische Daten ............................................................................................................................................. 12
Bitte lesen Sie vor Inbetriebnahme
der Pumpe die Bedienungsanleitung
Allgemeines Warnzeichen
SICHERHEITSHINWEISE UND WARNUNGEN