Ref. : 840000015
Manual
Eltra
nv, Pachtgoedstraat 2, 9140 Temse, BELGIUM
4
F. Countdown function
1.
When the LCD is in real time display, press V
-
Button once to change to countdown setting display, “d ON (or
OFF)” will be shown on the lower left corner of the LCD
1.1
“d”: indicates the program is in countdown mode
1.2
“ON”: counting down the power on time
1.3
“OFF”: counting down the power off time
2.
Press SET Button until the on/off display flashes, setting the countdown power on/off status is ready.
3.
Press
V+
/
∨-
Button to choose countdown on/off program and press SET Button to confirm
4.
Hour display flashes after setting the on/off status, then press
V+
/V
-
Button to increase or reduce hour and
press SET Button to confirm.
5.
Minute display then flashes, press
V+
/
V
-
Button to increase or reduce minute and press SET Button to confirm
6.
Second display flashes, press
V+
/
V
-
Button to increase or reduce the hour display and press SET Button to
confirm. Setting interval is from 99:59:59 to 1 second.
7.
Connect the Timer to the AC socket and set the Timer to AUTO status in order to start /stop the countdown
functions.
8.
Press CD Button once to start the countdown function, “d ON (or OFF)” flashes in the lower corner of the LCD to
indicate countdown is in progress. Press CD Button again to stop the countdown function.
Note:
(a). When countdown is in progress, LCD is in real time display, press
V
-
Button once to view the countdown details.
(b) To change a preset program, repeat the above procedures #2 to #6 in
Part F Countdown Setting
and input the
new data to replace the old setting
(b). After program setting, press CLOCK Button to return to clock display at once, or it will be returned
automatically after 15 seconds without pressing any other buttons.
G. Random function
1.
Random function turns on and off the appliance irregularly:
1.1
Minimum time for power off:
26 minutes
1.2
Maximum time for power off:
42 minutes
1.3
Minimum time for power on:
10 minutes
1.4
Maximum time for power on:
26 minutes
2.
Connect the Timer to the AC socket and set the program to AUTO status in order to start/stop the
random function.
3.
Press RND Button once, “r OFF” is flashing in the lower corner of the LCD, random function is
activated. Power is off for 26 to 42 minutes. The mode will change to “r ON”, where power turns on
from 10 to 26 minutes. Then back to “r OFF” again.
Press RND Button again can stop the random function, “r OFF”or “r ON” disappears from the LCD
Note :
Random function doesn not work when no program is setup. Firstly setup your standard programming to activate these intervals
with the RND button :