11
The hydrotherapy spa is designed to seat seven
adults. The spa holds approximately 375 gallons of
water and offers a heating system (80°F to 104°F), a
filtration system, and adjustable hydrotherapy jets.
Follow the guidelines below to use and maintain the
spa for your long-term enjoyment.
Once the spa is filled with water, the power can be
turned on. Note: If this is the first time the spa has
been turned on, or if the pumps have been
drained, the pumps must be primed before the
spa can be used.
PRIMING THE PUMPS
To prime the pumps, follow the steps below.
1. Remove the access panels (see ATTACHING AND
REMOVING THE ACCESS PANELS on page 18).
2. Make sure all of the gate valves in the plumbing
system are open to allow as much air as possible
to escape from the plumbing and the controller
during the filling process (see step 2 on page 9).
Fill the spa to the level shown in step 3 on page
10. Use towels to soak up any water that leaks
from the plumbing and the pumps.
3. Loosen the indi-
cated collar on
one of the
pumps to vent
the air from the
pump. Repeat for
the other pump.
Allow a small
amount of water
and air to escape from the pumps and related
plumbing. Then, retighten the collars.
4. Turn the power on at the breaker. The spa will
begin an automatic priming sequence.
A countdown from “005” to “000” will appear in the
display of the console.
Once the countdown has reached “000,” “Pr” will
be displayed. “Pr” indicates that the controller is in
the two-pump priming mode. This mode will last
for four to five minutes.
5. As soon as “Pr” is displayed, push pump button 1
once to start the pump on low speed and then
push the button again to switch to high speed.
Repeat for pump button 2.
If water is not flowing from the jets after two min-
utes, turn the power off. Important: Do not allow
the pumps to run without priming for more
than two minutes. Under no circumstances
allow a pump to run without priming beyond
the end of the four to five minute priming
mode. Doing so may cause damage to the pump
and cause the spa to go into an overheat condi-
tion.
Repeat the process of venting the air from the
pumps and the controller and priming the pumps
until water flows from the jets.
6. When the priming sequence is completed, the spa
will automatically return to the normal heating and
filtering mode. During the priming process, the
heater is disabled to allow the pumps to be primed
without activating the heater under low flow or no
flow conditions.
Once the pumps are primed, push pump button 1
and pump button 2 to turn the pumps off.
7. The console will display “100F” and then “--F,” for
approximately one minute. The spa requires one
minute of water flowing through the heater to
determine the water temperature.
Using the Hydrotherapy Spa
Loosen this
Collar