WARNING!
The ceiling heater must be grounded in accordance with all national
and local building codes.
All wiring must be completed by a certified electrician.
Before installation
Disconnect the main supply connection.
Supply cables shall be 10 AWG (5.3 mm
2
) copper wires.
Supply cables must be equipped with a dual pole circuit breaker rating of
at least 240 V 30 A/pole as main cutoff switch of power connection to
the heater.
CAUTION!
High temperature. Risk of fire. Keep electrical cords, drapery, furnishings
and other combustibles at least 3
’
(0.9 m) from the front of the
heater and away from the sides and rear.
The heater must be connected to individual branch circuit protected
by 30 Amp circuit breaker only.
WARNING!
To reduce the risk of fire, do not store or use gasoline or other
flammable vapors and liquids in the vicinity of the heater.
All Wiring procedures and connections shall be in accordance
with the national and local codes having jurisdiction.
052-2532-8
MODEL:PH-945