There is a timing which affects all filters equally: 

the pause between filters. This timing is important to 
recover pressures in the net and avoid overlapping in 

the hydraulic valves.  

 
Both a cleaning sequence and the outlets can be 

started or stopped manually with the unit. The unit can 
also be set at stop (deactivated). 

 
The user can easily program all the parameter 

and timing values of the controller. 

 

The unit shows the state of the unit at all times, 

indicating the filter that is working, whether it is 
working, the state of the inputs and whether there is 
any outlet which has been activated in a manual way 
as well as showing whether the controller is at stop. It 

also informs about the circulating instantaneous flow 
and about the volume and time units that have gone 
by since the last cleaning. 

At the TOTALS function, the unit shows the 

number of cleanings that have taken place due to a 

“drop in pressure” and “volume” or “time”. The total 
water volume, which has circulated through the filters 
or the time it, has been working, since the last time it 
was set at zero are also indicated. 

 
The unit has the following inputs: 
 
- For the differential pressure gauge which 

detects the drop in pressure in the filters, (necessary 

for the starts by “drop of pressure”), 

- For the detection of water flow through the 

filters with a signal that comes from a programmer, 
calliper, etc., (necessary for the starts “by time” and 
for the total of hours that the filter installation has been 

working), 

- For the volumetric impulse transmitter, 

(necessary for the starts by “volume”, information 
about the instantaneous flow and volume total of 
filtered water), 

- For the detection of breakdowns in the 

installation, 

-  For different options. 

 
A timing for detection delay can be assigned to 

the inputs, in order to avoid inadequate signals. 

 
There can be three types of outlet: at 24 Vac, at 

12 Vdc and at 12 Vdc for latch valves (with two or 
three wires) with low consume. 

 

MODELS AND OPTIONS 

-

 

Models for 6, 12, 18 outlets. 

-

 

220 Vac version and 24 Vac outlets. 

-

 

12 Vdc version and 12 Vdc outlets. 

-

 

Version with the equipment provided in a box with 

transparent cover. 

-

 

Version with the equipment prepared to build-in a 

cupboard or a desk. 

-

 

Option with outlets for latch valves (with two or 

three wires) and low consume. Due to the fact that this 
version has a low consume of the unit and its 

electrovalves, it is very suitable for those installations 
which work with a battery and which do not have a 
diesel engine or a solar cells to recharge it.  

-

 

Version for filters with cleaning and rinse. It can 

have 2, 4 or 6 filters. Every filter uses three relays to 
control the 5 necessary hydraulic valves. The 
programmer will ask for every filter the cleaning and 
rinsing time. 

 

WARRANTY 

The Agrónic filter controller meets all the norms set 

by the EC. 

The products created by PROGRÉS enjoy a two-

year warranty against all manufacturing defects. 

Compensation for direct or indirect damage 

caused by the use of the equipment is excluded from 
the guarantee. 

 
 

GRAPHIC OF A FILTER CLEANING SEQUENCE 

 

-Example A- Without pause timing between filters. 

 

Cleaning start 

 End 

General outlet 

 

B1   

Filter 1 outlet 

 

 

 

 B2   

Filter 2 outlet 

 

 

 

 -------- 

Bn 

Filter n outlet 

 

 

 

 

(B1-n)  - Working seconds per filter 

-Example B- With pause timing between filters. 

 

Cleaning start 

 End 

General outlet 

 

B1    

Filter 1 outlet 

 

 

 

   

B2  

Filter 2 outlet 

 

 

 

 

--- A 

 

Filter n outlet 

 

 

 

 

(A) - 

Pause seconds between filters 

  

Summary of Contents for Agronic

Page 1: ...re are 3 different models according to the number of filters to control for 6 12 and 18 filters Models for 6 and 12 filters can be increased whenever necessary up to 18 sending them back to the factor...

Page 2: ...flow and volume total of filtered water For the detection of breakdowns in the installation For different options A timing for detection delay can be assigned to the inputs in order to avoid inadequa...

Page 3: ...er and an opaque cover for the connection housing To maintain the isolation of the unit it is essential to keep the panels closed as well as to install grommets at the cable outlets which are provided...

Page 4: ...that those cables supply other units or elements If the battery is far away from the controller use high section cables and make a reduction when entering the equipment The input is also protected wit...

Page 5: ...rk properly a There is a black stripe on the screen Unplug the unit open it remove the keyboard and with a screwdriver cross the two contacts on the central part of the left side marked as J3 during t...

Page 6: ...o the outputs see indicative stick Without the bridge the outputs are working to 12 Vdc and with the bridge installed they will have a voltage near to 24 volts From the company the units are delivered...

Page 7: ...nsion for the Fulfilment of the Product Security The fulfilment of the following specifications was demonstrated as indicated in the Official Diary of the European Communities Emissions EN 50081 1 94...

Page 8: ...will only be asked if the unit was configured to work by volume Impulse value is the value of the water which has circulated every time the volumetric counter gives an impulse The value can go from 00...

Page 9: ...re gauge The third screen asks whether these data are to be erased by time by volume 5 6 CONSULTATION On pressing the CON key the following screen will be displayed The first screen shows the number o...

Page 10: ...10 R 910 1...

Reviews: