background image

50mm

Screws

Pilot drill holes
before fixing

OSB Floor Stages

Fix the floors
together, with
screws in angled
positions.

Back

Front

Tongue and Groove Floor option

20x6 Floor

panels shown

Align the tongue and
groove floor panels

Side

Front

Back

OSB Floor Stages

20x6 Floor

assembly

Lay and align
the floors

*All Garden Buildings must be built on level,
flat base to be erected correctly.

Side

Front

Back

18mm

Wall Panel

Floor
Panel

Side View

1812mm

18mm

18mm

Side View

Fr

on

t

Back

Wall Panels and Floor Panels Position

50mm

Screws

Side

Pilot drill holes
before fixing

Fix the Panels
to the floor

Fix the back panel
and side gable
together.

4ft Plain

Panel

10x6 Door on the
left will have a
3ft plain panel

50mm

Screws

Pilot drill holes
before fixing

Tongue and Groove Floor option

Fix the floors
together, with
screws in angled
positions.

Back

Front

1

4

5

6

2

3

Summary of Contents for 20x6 Hobbyist Windowed Pent Shed

Page 1: ...read the instruction carefully and retain for future reference For Queries and Help please contact 01777 802300 Please note that all images are for illustration purpose only V1 4 08 08 22 INS0067 20x...

Page 2: ...forweathertochangebeforenotifyingusifyounoticechangesinthestructure TOOLS REQUIRED Drill with 4 5 3 and 2mm drill bit Hammer Spirit Level Measuring Tape Screwdriver Phillips Stanley Knife Wood Saw Ste...

Page 3: ...he fixing kit for safer transportation If they are still not found please visit our Support Centre care projecttimber co uk Q What tools do I require A Drill with 4 5 3 and 2mm drill bit Hammer Spirit...

Page 4: ...set Door shown 16x6 Hobbyist Windowed Pent Shed Offset Door shown 14x6 Hobbyist Windowed Pent Shed Offset Door shown 12x6 Hobbyist Windowed Pent Shed Offset Door shown 10x6 Hobbyist Windowed Pent Shed...

Page 5: ...m x 1172mm 5 18x6 Floor Assembly 1812mm x 1172mm 3 1812mm x 879mm 2 16x6 Floor Assembly 1812mm x 1172mm 4 14x6 Floor Assembly 1812mm x 1172mm 2 1812mm x 879mm 2 12x6 Floor Assembly 1812mm x 1172mm 3 1...

Page 6: ...of Position 20x6 Roof Position 4ft 4ft 4ft 4ft 4ft 18x6 Roof Position 3ft 4ft 4ft 4ft 3ft 16x6 Roof Position 3ft 4ft 3ft 3ft 3ft 14x6 Roof Position 4ft 4ft 3ft 3ft 12x6 Roof Position 4ft 4ft 4ft 10x6...

Page 7: ...anel Position 20x6 TG Roof Position 4ft 4ft 4ft 4ft 4ft 18x6 TG Roof Position 3ft 4ft 4ft 4ft 3ft 16x6 TG Roof Position 4ft 3ft 3ft 3ft 3ft 14x6 TG Roof Position 4ft 4ft 3ft 3ft 12x6 TG Roof Position...

Page 8: ...Plain Panel 3ft Plain Panel 3ft Plain Panel 4ft Plain Panel 4ft Plain Panel 16x6 Back Panels Position 4ft Plain Panel 3ft Plain Panel 3ft Plain Panel 3ft Plain Panel 3ft Plain Panel 14x6 Back Panels P...

Page 9: ...4ft Window Panel Double Door Panel 4ft Window Panel 3ft Window Panel 16x6 Front Panels Position 3ft Window Panel 3ft Window Panel Double Door Panel 3ft Window Panel 3ft Window Panel 14x6 Front Panels...

Page 10: ...st be built on level flat base to be erected correctly Side Front Back 18mm Wall Panel Floor Panel Side View 1812mm 18mm 18mm Side View Front Back Wall Panels and Floor Panels Position 50mm Screws Sid...

Page 11: ...nel Floor Assembly Gable Panel Wall Panel Position 50mm Screws Front Side Pilot drill holes before fixing Fix the back panels Secure the panels to the floor panels 50mm Screws Front Fix the left gable...

Page 12: ...n Can be on the Left or Right Purlin fixing Fix the L Bracket on each end of purlin 30mm Screws Pilot drill holes before fixing Purlin fixing Fit and fix the purlins Front Back 30mm Screws See L brack...

Page 13: ...s with 100mm screws Front Back 100mm Screws Pilot drill holes before fixing Purlin fixing Position and fix in place the purlin to the wall panels Front 30mm Screws Pilot drill holes before fixing Fron...

Page 14: ...in and wall panels Back Front OSB Roof fixing Fix the OSB roof sheet to the purlin and wall panels Back 30mm Nails OSB Roof fixing Fix the eaves purlin to the roof sheet 30mm Nails OSB Roof fixing Rep...

Page 15: ...k Soffit fixing Position the soffit to the front of tongue and groove roof panel Front Back 11mm x 45mm x 1172mm 11mm x 45mm x 879mm 41mm Side View Roof Overhang Dimension Front Back Tongue and Groove...

Page 16: ...ecure the roof panel Front Pilot drill holes before fixing 70mm Screws Window Glazing fixing Place the Glazing into Window Panel and fit the Beading on both sides Fit the rest of the Glazing and Beadi...

Page 17: ...ng 30mm Screws Turn Button Lock fixing Bottom Top 30mm Screws Door Fixing 30mm Screws 30mm Nails Corner Cloaking Strip fixing 30mm Nails Corner Cloaking Strip fixing Turn Buttom Lock fixing 30mm Screw...

Page 18: ...ame 30mm Nails Cut to size Cloaking Strip fixing Roof Packing Frame fixing TG roof 50mm Screws Pilot drill holes before fixing Position and fix the roof packing frame at each side end of the building...

Page 19: ...ure and cut 2 lenghts of Felt Roof length 140mm Roof Felt fittings for TG Roof T10 Felt Tacks On the front the felt tacks tack into the roof purlins Side Fascia fixing Side Fascia Board 60mm x 11mm x...

Page 20: ...1240mm 1240mm 1170mm 1170mm 2115mm 2115mm Front Fascia Length Diagram Front Fascia 12ft Wide Building Front Fascia 10ft Wide Building Front Fascia 8ft Wide Building 1822mm 1822mm 1530mm 1530mm 1235mm...

Reviews: